• Title/Summary/Keyword: the shear bond strength

Search Result 857, Processing Time 0.052 seconds

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Influence of nano-structured alumina coating treatment on shear bond strength between zirconia ceramic and resin cement (나노구조 알루미나 코팅 처리가 지르코니아 도재와 레진 시멘트 사이 전단 결합강도에 미치는 영향)

  • Kim, Dong-Woon;Lee, Jung-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.354-363
    • /
    • 2016
  • Purpose: The aim of this study was to investigate whether the application of nano-structured alumina coating to the surface of Y-TZP could enhance the bond strength with resin cement. Materials and methods: A total of 80 zirconia plates were prepared and divided into four groups. : 1) airborne particle abrasion treatment (A) : 2) Rocatec treatment after airborne particle abrasion (R) : 3) nano-structured alumina coating treatment after polishing (PC) and 4) nano-structured alumina coating after airborne particle abrasion (AC). Alumina coating was formed by the hydrolysis of aluminium nitride (AlN) powder and heat treatment at $900^{\circ}C$. Coating patterns were observed with FE-SEM. Resin block was bonded to treated zirconia ceramics using resin cement. The shear bond strengths were measured before and after thermocycling. Results: The FE-SEM images show a dense and uniform nano-structured alumina coating structure, which enhances shear bond strength by increasing micro mechanical interlocking to resin cement. PC and AC groups showed higher shear bond strengths than A and R groups before and after thermocycling. A and R groups displayed significant drops in shear bond strength after thermocycling. However, PC and AC groups did not show any meaningful decreases in shear bond strength after thermocycling. Conclusion: Treatment of Y-TZP ceramics with nano-structured alumina coating could significantly increase their shear bond strength.

The Effect of Resin Base Surface Treatment on Shear Bond Strength in Indirect Bracket Bonding Technique (브라켓 간접부착술식시 레진베이스의 표면처리가 전단결합강도에 미치는 영향)

  • Yim, Byeong-Cheol;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.681-688
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of the surface treatments of resin bases in indirect bracket bonding technique by study of shear bond strengths and failure patterns. Ninety metal brackets were bonded to the stone models of specimens involving bovine lower incisor with light-cured adhesive(Light-Bond). After removal of brackets with the resin base from the stone models, the surfaces of resin bases in thirty brackets were treated with Plastic Conditioner and the surfaces of resin bases in another thirty brackets were treated with sandblaster and the remaining thirty brackets were served as controls. All brackets were transferred to the specimens and bonded using sealant. The shear bond strength was tested on universal testing machine, and failure pattern was assessed with the adhesive remnant index(ARI). The results were as follows: 1. Surface treatments of resin bases with Plastic Conditioner or sandblasting showed statistically higher shear bond strengths than no treatment group. 2. No significant difference in shear bond strength was found between Plastic Conditioner treatment and sandblasting treatment groups. 3. No significant difference in ARI scores was found among the three groups. 4. As the result of correlation analysis between shear bond strengths and hnl scores, failure at adhesive/bracket base interface tends to increase when the shear bond strength was high, but it was not significant statistically. The above results suggest that improvement of bond strength can be obtained by surface treatment of resin base in the indirect bonding technique.

  • PDF

INFLUENCE OF MULTIPLE ADHESIVE COATINGS ON THE SHEAR BONDING STRENGTH OF COMPOSITE RESIN (접착제의 다층적용이 복합레진의 전단결합강도에 미치는 영향)

  • Park, Heon-Dong;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.377-387
    • /
    • 2006
  • The objective of this study was to evaluate the influence of multiple adhesive coatings on the thickness of hybrid and adhesive layer and shear bond strength(SBS) of self-etch adhesives and self-etch primer adhesives. The buccal or lingual crown dentin of extracted human molars was used. Self-etch adhesives or self-etch primer adhesives were applied 1, 2 and 3 times on the dentin before light curing. In another group adhesives were reapplied after light curing first layer. Treated surfaces were prepared to measure the thickness of hybrid and adhesive layer with SEM, and shear bond strength to dentin using an Instron machine. The following results were obtained : 1. The adhesive layers increased with the number of coatings(p<0.05) with all adhesives. Adpor Prompt L-Pop and Xeno III were significantly thinner than self-etch primer adhesives (p<0.05). 2. The thickness of hybrid layers increased with the number of coatings (p<0.05). 3. The shear bonding strength of Unifil Bond and Clearfill SE Bond were higher than Scotchbond Multipurpose Plus and Adpor Prompt L-Pop (p<0.05), and similar with Xeno III. 4. The shear bond strength increased significantly with the number of coatings in Adpor Prompt L-Pop(p<0.05), but decreased at 3 times in AdheSE Bond(p>0.05). 5. In Adpor Prompt L-Pop and Xeno III, the shear bond strength decreased when adhesives were reapplied after curing the first adhesive layer.

  • PDF

A Study on the Bond-Behavior of Bonded Concrete Overlays (접착식 콘크리트 덧씌우기 포장의 부착거동 연구)

  • Kim, Young-Kyu;Lee, Seung-Woo;Han, Seung-Hwan
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.31-45
    • /
    • 2012
  • PURPOSES: In Korea, rapid maintenance of distressed concrete pavement is required to prevent traffic jam of the highway. Asphalt concrete overlay has been used as a general maintenance method of construction for aged concrete pavement. AC overlay on existing concrete pavements experience various early distresses such as reflection crack, pothole and rutting, due to different physical characteristics between asphalt overlay and existing concrete pavement. Bonded concrete overlay(BCO) is a good alternative since it has advantages that can reduce various distresses during the service life since overlay material has similar properties with existing concrete pavements. Recently, BCO which uses the ultra rapid harding cement has been applied for maintenance of highway. BCO has advantage of structural performance since it does monolithic behave with existing pavement. Therefore, it is important to have a suitable bond strength criteria for securing performance of BCO. Bond strength criteria should be larger than normal tensile stress and horizontal shear stress occurred by traffic and environmental loading at bond interface. Normal tensile stress and horizontal shear stress need to estimated for the establishment of practical bond strength criteria. METHODS: This study aimed to estimate the bond stresses at the interface of BCO using the three dimensional finite element analysis. RESULTS: As a result of this study, major failure mode and maximum bond stress are evaluated through the analysis of normal tensile stress and horizontal shear stress for various traffic and environmental load conditions. CONCLUSIONS: It was known that normal tensile stresses are dominated by environmental loading, and, horizontal shear stresses are dominated by traffic loading. In addition, bond failure occurred by both of normal tensile stresses and horizontal shear stresses; however, normal tensile stresses are predominated over horizontal shear stresses.

Adhesion between heat-pressed lithium disilicate veneer and zirconia framework: Shear bond strength evaluation (열가압 리튬 디실리케이트 전장도재와 지르코니아 하부구조의 전단결합강도 평가)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.335-341
    • /
    • 2020
  • This study examined the shear bond strength between the zirconia core and pressed lithium disilicate veneering ceramics. The Schmitz-Schulmeyer test method was used to investigate the core-veneer shear bond strength of industrially manufactured zirconia core ceramic (Zirtooth, HASS, Gangneung, Korea) and pressed veneer ceramic (IPS e.max Zirpress, Vita PM9, GC Initial IQ, HASS Rosetta SM) (N=40). Data were statistically analyzed using one-way ANOVA and Tukey's test (a=0.05). The fractured surfaces of the specimens were examined to determine the failure pattern using a digital microscope. The mean ± SD shear bond strength in MPa were 16.69±3.11, 14.21±3.63, 11.17±2.92, and 27.90±5.71 for IPS e.max Zirpress, VITA PM9, GC Initial IQ, and HASS Rosetta SM, respectively. The average shear bond strength was largest for HASS Rosetta SM, followed by IPS e.max Zirpress, Vita PM9, and GC Initial IQ(p<0.05). The digital microscopy examination of the fracture surface showed adhesive and cohesive failure in pressed lithium disilicate veneering ceramics. The use of lithium disilicate veneer ceramic produced a significantly higher shear bond strength.

EFFECTS OF METAL SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH BETWEEN NI-CR DENTURE BASE AND RELINE RESINS (금속 표면처리방법이 니켈-크롬 합금 의치상과 첨상레진간의 결합강도에 미치는 영향)

  • Kim Young-Il;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • The purpose of this study was to evaluate the effects of four metal surface treatments on the shear bond strength of reline resin to Ni-Cr alloy. The denture base metal used in this study was Ni-Cr alloy(Ticonium Premium 100. Ticonium Co., U.S.A.). 120 specimens were divided into five metal surface treatments: sandblasting only, MR. BOND(Tokuyama Corp.. Japan), Cesead Opaque Primer(Kuraray Co., Japan), METALPRIMER II(GC Corp., Japan) and Super-Bond C&B(Sun Medical Co., Japan) after sandblasting. They were bonded with one of three reline resins Mild Rebaron(GC Corp., Japan), Mild Rebaron LC(GC Corp., Japan) and Meta Base M(Sun Medical Co., Japan). Then they were thermocycled 1,000 times at temperature of $4^{\circ}C$ and $60^{\circ}C$. The shear bond strengths were measured using the universal testing machine(Instron, Model 4301, England) with a cross-head speed of 2 mm/min. The results were as follows : 1. All metal primers and adhesive cement significantly improved the bond strength of reline resin to Ni-Cr alloy compared with sandblasted specimens. 2. In Mild Rebaron and Mild Rebaron LC. Cesead Opaque Primer showed the highest bond strength, but the differences among Cesead Opaque Primer, MR. BOND and METALPRIMER II were not significant. The bond strength of Cesead Opaque Primer was significantly different with that of Super-Bond C&B. 3. In Meta Base M, Super-Bond C&B showed the highest bond strength, but there was no difference between Super-Bond C&B and three metal primers. 4. There was no difference in the bond strength between Mild Rebaron and Mild Rebaron LC when metal surface was treated with the same method. 5. The bond strengths of Mild Rebaron and Mild Rebaron LC treated with Cesead Opaque Primer were higher than that of Meta Base M. The bond strengths of Mild Rebaron treated with MR. BOND and METALPRIMER II was higher than that of Meta Base M, However, there was no difference among three reline resins treated with Super-Bond C&B.

Shear Bond Strength of a 3-in-1 Flowable Composite Resin to Primary Teeth (유치에 대한 3-in-1 유동성 복합레진의 전단결합강도)

  • Lee, Hyeongjik;Shin, Jonghyun;Kim, Jiyeon;Jeong, Taesung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.436-444
    • /
    • 2018
  • The purpose of this study was to compare the shear bond strengths of 3-in-1 flowable composite to the enamel and dentin of primary teeth to previous adhesive systems. 110 primary incisors were prepared and divided into two groups: Dentin group included 5 groups: 1) Scotch bond Multi-purpose plus(DSM), 2) Single-bond 2(DSB), 3) Clearfil SE bond(DSE), 4) All bond universal(DAB), 5) Constic(DC), and Enamel group included 6 groups: 1) Scotch bond Multi-purpose plus(ESM), 2) Single bond 2(ESB), 3) Clearfil SE bond(ESE), 4) All bond universal(EAB), 5) Constic(EC), 6) Constic with additional etching(ECE). A cylinder of composite was bonded to the prepared surface, and the shear bond strength was measured. In the dentin groups, group DC had significantly lower shear bond strength than group DSE. No significant difference was found between group DC, group DSM, group DSB and group DAB. In the enamel groups, there was no significant difference between group EC, group ESE, and group EAB. This material showed lowest shear bond strength among all tested materials in both enamel and dentin groups, showing insignificant difference with some adhesive systems. Therefore, 3-in-1 flowable composite can be used for primary teeth restoration but further studies are needed.

Investigation of the Shear Bond Strength of Orthodontic Buttons by Light Curing Using an Extended Optic Fiber (광섬유를 이용한 광중합에 따른 교정용 버튼의 전단결합강도에 관한 연구)

  • Yoon, Garam;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan;Choi, Wonseok;Sung, Minah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.105-114
    • /
    • 2021
  • The objective of this study is to analyze the shear bond strength of orthodontic buttons according to light tip distance and optic fiber diameter when an extended optic fiber was applied to the tip of a curing light unit. In this study, 315 extracted premolar teeth were divided into 3 groups. Orthodontic buttons were attached using no optic fibers (Group I), 3.0 mm diameter optic fibers (Group II), or 5.0 mm diameter optic fibers (Group III). Each group was divided into subgroups A - C (5.0, 10.0, and 15.0 mm light tip distance), respectively. Shear bond strength was then measured while varying the light tip distance. In group I, shear bond strength significantly decreased as the light tip distance increased. When the shear bond strength was evaluated according to the optic fiber diameter, no statistical significance was observed in group of 5.0 mm light tip distance. Compared with group IB, group IIIB showed significantly greater shear bond strength. Compared with group IC, all groups using 3.0 or 5.0 mm diameter optic fibers showed significantly greater shear bond strength. Therefore, when a curing light unit has poor accessibility, optic fibers with a large diameter should be considered.

A Study for Adfreeze Bond Strength Developed between Weathered Granite Soils and Aluminum Plate (동결된 화강풍화토와 알루미늄판 접촉면에서 발현되는 동착강도 측정 연구)

  • Lee, Joonyong;Kim, Youngseok;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.23-30
    • /
    • 2013
  • Bearing capacity of pile is governed by only skin friction in frozen ground condition, while it is generally governed both by skin friction and end bearing capacity in typically unfrozen ground condition. Skin friction force, which arises from the interaction between pile and frozen soils, is defined as adfreeze bond strength, and adfreeze bond strength is one of the most important key parameters for design of pile in frozen soils. Many studies have been carried out in order to analyze adfreeze bond strength characteristics over the last fifty years. However, many studies for adfreeze bond strength have been conducted with limited circumstances, since adfreeze bond strength is sensitively affected by various influence factors such as intrinsic material properties, pile surface roughness, and externally imposed testing conditions. In this study, direct shear test is carried out inside of large-scaled freezing chamber in order to analyze the adfreeze bond strength characteristics with varying freezing temperature and normal stress. Also, the relationship between adfreeze bond strength and shear strength of the frozen soil obtained from previous study was analyzed. The coefficient of adfreeze bond strength was evaluated in order to predict adfreeze bond strength based on shear strength, and coefficients suggested from this and previous studies were compared.