• Title/Summary/Keyword: the power method

Search Result 22,450, Processing Time 0.048 seconds

Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid (계통연계 분산전원의 새로운 단독운전 판별기법)

  • Bae, Byung-Yeol;Lee, Doo-Young;Ko, Jong-Sun;Choi, Nam-Sub;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

Improved Lanczos Method for the Eigenvalue Analysis of Structures (구조물의 고유치 해석을 위한 개선된 Lanczos 방법)

  • 김병완;김운학;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.133-140
    • /
    • 2002
  • This paper investigates the applicability of the modified Lanczos method using the power technique, which was developed in the field of quantum physics, to the eigenproblem in the field of engineering mechanics by introducing matrix-powered Lanczos recursion and numerically evaluating the suitable power value. The matrix-powered Lanczos method has better convergence and less operation count than the conventional Lanczos method. By analyzing four numerical examples, the effectiveness of the matrix-powered Lanczos method is verified and the appropriate matrix power is also recommended.

  • PDF

Stability Improvement of Distributed Power Generation Systems with an LCL-Filter Using Gain Scheduling Based on Grid Impedance Estimations

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.599-605
    • /
    • 2011
  • This paper proposes a gain scheduling method that improves the stability of grid-connected systems employing an LCL-filter. The method adjusts the current controller gain through an estimation of the grid impedance in order to reduce the resonance that occurs when using an LCL-filter to reduce switching harmonics. An LCL-filter typically has a frequency spectrum with a resonance peak. A change of the grid-impedance results in a change to the resonant frequency. Therefore an LCL-filter needs a damping method that is applicable when changing the grid impedance for stable system control. The proposed method instantaneously estimates the grid impedance and observes the resonant frequency at the same time. Consequently, the proposed method adjusts the current controller gain using a gain scheduling method in order to guarantee current controller stability when a change in the resonant frequency occurs. The effectiveness of the proposed method has been verified by simulations and experimental results.

A New Carrierwave-Based SVPWM for Multilevel H-bridge Inverter (멀티레벨 H-bridge 인버터를 위한 새로운 carrierwave 비교 방식)

  • 강대욱;이요한;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.13-17
    • /
    • 1998
  • In recent years H-bridge multievel inverters have been focused on and selected as the power inverter in several high voltage and high power application. This paper proposes an new PWM method for the multievel H-bridge inverter systems. The proposed PWM method is a carrierwave-based space vector PWM method which utilizes the phase voltage redundancies considering both the switch and conduction loss of the devices. We describe the new PWM method in detail and the effectiveness of the new PWM method is verified by the simulation results.

  • PDF

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF

Research for the survey of method to serviced customer Interruption cost evaluation (전력수용가 정전비용 산출물 위한 설문조사 방법론에 관한 연구)

  • Park, Soo-Man;Kim, Jae-Chul;Moon, Jong-Fil;Bae, Ju-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.259-261
    • /
    • 2002
  • KEPCO(Korea Electric Power Corporation) has been management alone before some time. However through the electrical industry reorganization generation and KPX(Korea Power Exchange) were separated on 2001. A marketing and distribution part will be separated in the future. While many problem for appear in future. how to management for power system network is important. unfortunallity, electrical power industry is starting point right now. Thus, detail data is incomplete for this field and detail research for this field is required with distribution reorganazation. In this paper suggest for customer interruption cost compute method to establish a standard. The standard is need to security operation of power system network. The customer interruption cost compute method necessity of customer interruption cost compute method is minimizing process for total cost. As final total cost compute through the interruption cost compute, we can recognize investment point exactly. We cited foreign survey questions, because exactly matched survey questions for in the country circumstance is not exist. And process to survey performance suggest after modify for match in the country circumstance. Survey questions that suggested fer this paper are classified five categories. This paper suggests to detail survey questions and survey method before survey and suggest to how to customer interruption compute when survey data is ensured. Moreover this paper suggest to average interruption cost compute for residential customer using statistical method.

  • PDF

A Study on Optimal Power Flow Using Interior Point Method (Interior Point Method를 이용한 최적조류계산 알고리듬 개발에 관한 연구)

  • Kim Balho H.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.457-460
    • /
    • 2005
  • This paper proposes a new Interior Point Method algorithm to improve the computation speed and solution stability, which have been challenging problems for employing the nonlinear Optimal Power Flow. The proposed algorithm is different from the tradition Interior Point Methods in that it adopts the Predictor-Corrector Method. It also accommodates the five minute dispatch, which is highly recommenced in modern electricity market. Finally, the efficiency and applicability of the proposed algorithm is demonstrated with a case study.

A Basic Method for Composite Power System Expansion Planning under Security Criteria (안전도 제약을 고려한 복합전력계통의 확충계획에 관한 기초연구)

  • Kwon, Jung-Ji;Tran, TrungTinh;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.557-559
    • /
    • 2005
  • This paper proposes a method for choosing the best composite power system expansion plan considering a contingency security criterion. The proposed method minimizes the investment budget fer constructing new transmission lines subject to contingency criterion. it models the power system expansion problem as an integer programming one. The method solves for the optimal strategy using a branch and bound method that utilizes a network flow approach and the maximum flow-minimum cut set theorem. Although the proposed method is applied to a simple sample study, the test results demonstrate that the proposed method is suitable for solving the power system expansion-planning problem subject to practical future uncertainties.

  • PDF

Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method (병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.