• 제목/요약/키워드: the other air pollutants

검색결과 325건 처리시간 0.027초

경기도 시화공단 지역주민의 악취오염과 관련된 건강영향 평가 (Health Effects from Odor Pollution in Sihwa Industrial Complex)

  • 조수헌;김선민;주영수;김재용;최성우
    • Journal of Preventive Medicine and Public Health
    • /
    • 제32권4호
    • /
    • pp.473-481
    • /
    • 1999
  • Objectives: In recent days, the problem of odor pollution in community near Sihwa Industrial complex, Kynuggi Province is becoming of significant public concern. We have investigated the health effects of the Sihwa residents from odor pollution comparing with other less polluted areas. Methods: The Ansan and Kuri Cities were selected as control areas. The parents of the elementary and middle school students in these three areas were surveyed with structured questionnaire twice, Nov 1997 and Jure 1998 each. As a exposure index, the ambient air concentrations of five major air pollutants(particulates, $O_3,\;SO_2,\;NO_2$, CO) and subjective odor perception were used. We have focused health outcomes such as the prevalence of nonspecific irritant symptoms, respiratory disease among family members and the score of qualify of life(QOL). Results: Although the mean concentrations of major air pollutants except particulates were similar or lower in Sihwa than other areas, the odor perception rate and the monthly odor perception days were significantly higher. It suggested that odor producing chemical compounds are the major source of environmental pollution problem. There were higher prevalence rates of nonspecific irritant symptoms and respiratory disease among family members in Sihwa than other control areas. The QOL score was also lower in Sihwa. The odor perception proved to be a most important factor in reporting adverse health effects and lowering the QOL score. Conclusion: The residents living near Sihwa industrial complex were suffering from more adverse health symptoms and poorer QOL status than control areas. And it may be due to environmental odor pollution from industrial complex. Therefore, further research will be needed for monitoring of the responsible chemicals emitted from industries.

  • PDF

Size Distribution Characteristics of Particulate Mass and Ion Components at Gosan, Korea from 2002 to 2003

  • Han J.S.;Moon K.J.;Lee S.J.;Kim J.E.;Kim Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E1호
    • /
    • pp.23-35
    • /
    • 2005
  • Size distribution of particulate water-soluble ion components was measured at Gosan, Korea using a micro-orifice uniform deposit impactor (MOUDI). Sulfate, ammonium, and nitrate showed peaks in three size ranges; Sulfate and ammonium were of dominant species measured in the fine mode ($D_{p} < 1.8 {\mu}m$). One peak was observed in the condensation mode ($0.218\sim0.532{\mu}m$), and the other peak was obtained in the droplet mode ($0.532\sim1.8{\mu}m$). Considering the fact that the equivalent ratios of ammonium to sulfate ranged from 0.5 to 1.0 in these size ranges, it is inferred that they formed sufficiently neutralized compounds such as ($NH_{4})_{2}SO_{4} and (NH_{4})_{3}H(SO_{4})_{2}$ during the long-range transport of anthropogenic pollutants. On the other hand, nitrate was distributed mainly in the coarse mode ($3.1\sim6.2{\mu}m$) combined with soil and sea salt. Two sets of MOUDI samples were collected in each season. One sample was collected when the concentrations of criteria air pollutants were relatively high, but the other represented relatively clean air quality. The concentrations of sulfate and ammonium particles in droplet mode were the highest in winter and the lowest in summer. When the air quality was bad, the increase of nitrate was observed in the condensation mode ($0.218\sim0.282{\mu}m$). It thus suggests that the nitrate particles were produced through gas phase reaction of nitric acid with ammonia. Chloride depletion was remarkably high in summer due to the high temperature and relative humidity.

1994년 하절기의 심혈관계 및 호흡기계 초과사망 - 이상고온 및 대기오염의 영향을 중심으로 - (Summertime Heat Waves and Ozone : an Interaction on Cardiopulmonary Mortality? - Based on the 1994 Heat Wave in Korea -)

  • 성주헌;김호;조수헌
    • Journal of Preventive Medicine and Public Health
    • /
    • 제34권4호
    • /
    • pp.316-322
    • /
    • 2001
  • Objectives : To explore the possible effect of an interaction between summertime heat waves and ozone on cardiopulmonary mortality during the 1994 heat wave in Korea. Methods : The unusually hot summer of 1994 in Korea was defined as the heat wave in this study. We examined the associations of air pollutants with daily cardiopulmonary deaths between 1991-1995, considering the product term of the heat wave and each pollutant, weather and time trends. Results : During the heat wave, while temperatures were uniformly higher than those of other summers, the within-heat-wave difference in mortality paralleled that in the regional ozone levels. In terms of the influence of the heat wave, the results of ozone were different to those of total suspended particles (TSP) and sulfur dioxide $(SO_2)$. The ozone association (relative risk (RR) : 1.036; 95% confidence interval (CI) = 1.018-1.054) was observed only under heat wave conditions, while the TSP (RR : 1.006, 95% CI = 0.999-1.012) and the $SO_2$ (RR = 1.018, 95% CI : 1.011-1.024) associations were found under normal weather conditions (per interquartile increase of each pollutant; results of three pollutants model). The ozone association under heat wave was attributable to the statistical interaction between the heat wave and ozone. Conclusions : These results support the possibility of a biological synergy between the heat wave and ozone, one that is not evident between the heat wave and other major pollutants like particles or $SO_2$.

  • PDF

서울 및 6대 광역시의 기상요인을 고려한 대기오염이 주요 알레르기질환에 미치는 영향 (The Effect of Air Pollution on Allergic Diseases Considering Meteorological Factors in Metropolitan Cities in Korea)

  • 김효미;허진아;박윤형;이종태
    • 한국환경보건학회지
    • /
    • 제38권3호
    • /
    • pp.184-194
    • /
    • 2012
  • Objectives: We investigated the effects of air pollution on allergic diseases (allergic rhinitis, asthma, atopic dermatitis) in metropolitan cities in Korea, adjusting for meteorological factors. Methods: Data on daily hospital visits and hospital admissions for 2003-2010 was obtained from the National Health Insurance Cooperation. Meteorological data was obtained from the Korea Meteorological Administration. We then calculated daily mean temperature, daily mean humidity, daily mean air pressure at sea level, and diurnal temperature range. We used data on air pollution provided by the National Institute of Environmental Research. Maximum daily eight-hour average ozone concentrations and the daily mean $PM_{10}$ were used. We estimated excess risk and 95% confidence interval for the increasing interquatile range (IQR) of each air pollutant using Generalized Additive Models (GAM) that appropriate for time series analysis. Results: In this study, we observed an association between ozone and hospital visits for allergic rhinitis, asthma, and atopic dermatitis in all metropolitan cities, adjusting for temperature, humidity, air pressure at sea level, diurnal temperature range, and day of the week. Ozone was associated with hospital visits for allergic rhinitis, asthma, and atopic dermatitis across all metropolitan cities. However $PM_{10}$ was associated with allergic-related diseases in only select cities. Also, ozone and $PM_{10}$ were associated with hospital admission for asthma in all cities except Gwangju. Hospitalization for the other diseases failed to show consistent association with air pollutants. Conclusion: In the findings of this study, there was a significant association between air pollutants and allergic-related diseases. More detailed research subdivided age group or conducting meta-analyses combining data of all cities is required.

A Review on the Photochemical Oxidant Modeling as Applied to Air Quality Studies in Complex Terrain

  • Lee Hwa-Woon;Kim Yoo-Keun;Won Gyeong-Mee;Park Jong-Kil
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권1호
    • /
    • pp.19-33
    • /
    • 1997
  • The high oxidants, which occur the daily maximum concentrations in the afternoon, are transported into the other region via long range transport mechanisms or trapped within the shallow mixing boundary layer and then removed physically (deposition, transport by mountain wind, etc.) and chemically (reaction with local sources). Therefore, modeling formation of photochemical oxidants requires a complex description of both chemical and meteorological processes. In this study, as a part of air quality studies, we reviewed various aspects of photochemical modeling on the basis of currently available literature. The result of the review shows that the model is based on a set of coupled continuity equations describing advection, diffusion, transport, deposition, chemistry, emission. Also photochemical oxidant models require a large amount of input data concerned with all aspects of the ozone life cycle. First, emission inventories of hydrocarbon and nitrogen oxides, with appropriate spatial and temporal resolution. Second, chemical and photochemical data allowing the quantitative description of the formation of ozone and other photochemically-generated secondary pollutants. Third, dry deposition mechanisms particularly for ozone, PAN and hydrogen peroxide to account for their removal by absorption on the ground, crops, natural vegetation, man-made and water surfaces. Finally, meteorological data describing the transport of primary pollutants away from their sources and of secondary pollutants towards the sensitive receptors where environmental damage may occur. In order to improve our present study, shortcomings and limitation of existing models are pointed out and verification process through observation is emphasized.

  • PDF

장거리이동 대기오염물질 이동량의 공간적 분포와 변화 추이(1997~2004) (Spatial Distribution and Variation of Long-range Transboundary Air Pollutants Flux during 1997~2004)

  • 한진석;김영미;안준영;공부주;최진수;이상욱;이석조
    • 한국대기환경학회지
    • /
    • 제22권1호
    • /
    • pp.99-106
    • /
    • 2006
  • Aircraft measurements have been executed for the purpose of monitoring the long range transported air pollution and estimation of air pollutant in/out-flux over the Yellow sea. Total 74 missions of measurements have been done since 1997, mainly in spring and fall. The main study domain was over $124^{\circ}$E $/sim$ $124^{\circ}$E, $35^{\circ}$N $/sim$ $37^{\circ}$N below 3,000m. In long-term trends, mixing ratios of $SO_{2}$N were around 2 ppbv expect in summer ( < 1 ppbv). NOx exhibited 24 ppbv and have no clear annual trends over the Yellow Sea. The concentrations of 03 were 51, 58, 41 ppbv in spring, summer and fall-winter, respectively. Backward trajectory was performed for three days to investigate the source regions of the air mass. Six regions were divided around Korea peninsular centering at $36^{\circ}$N, $126^{\circ}$E. I, II, III, IV and V regions represents in sequence northeast China and Siberia, Sandong peninsula and Balhae gulf, Sanghi and southern China, the south Pacific included Jeju island and the East sea included Japan. L region correspond to the airmass from Korea peninsula. Influx of $SO_{2}$N was approximately five times higher than outflux in yearly flux variation and showed a decreasing long-term trend since 1998. NOx outflux was average 0.095 ton/km/hr and three times higher than $SO_{2}$ outflux. In/out flux of 03 showed even distribution in yearly basis except 2002 (influx 5.45 ton/km/hr). The transported amounts from I, II, III regions were much higher than those from other region. In seasonal flux variation, influx levels of gas phases were the lowest in summer and the levels gradually increased from fall toward spring. As a result, transport of pollutants begins from fall and prevails in winter and spring.

다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구 (A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes)

  • 안광훈;권종원;김규식;김희식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

카본블랙을 혼입한 시멘트 경화체의 특성 (Properties of Cement Matrix using Carbon Black)

  • 이전호;이창우;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2021
  • With the prolonged Covid-19 epidemic, movement restrictions such as social distancing are prolonged, and as people stay indoors for a longer time, interest in indoor air pollution is increasing. Indoor air quality is not easily purified unlike outdoors. Among indoor building materials, paints and flooring contain formaldehyde that causes sick house syndrome and VOCs that contain carcinogenicity and harmfulness. For modern people who spend a lot of time living indoors for more than an hour, the occurrence of these harmful substances can be said to be fatal. In response to these risks, in July 2019, the government reinforced the standards for indoor air quality to protect the public's health by raising the detection standards for fine dust, ultrafine dust, and formaldehyde in indoor multi-use facilities. People use machines such as air purifiers to improve indoor air quality, or make efforts such as periodic ventilation. In order to reduce or support these other ancillary efforts more effectively, to reduce the generation of pollutants in the building itself, or to adsorb or purify pollutants in the air, use carbon black as an admixture to make a cement hardened body, and to grasp basic physical properties and adsorption capacity. And the result is as follows. As a result of the experiment to determine the appropriate amount of carbon black, it was confirmed that the more the amount of carbon black was added, the better it was in the formaldehyde emission test, but the tendency was not clear when measuring the flexural strength, so a further experiment to improve this is needed.

  • PDF

2006년 봄, 여름철 대기오염물질 집중측정을 통한 도시 계곡지역의 오존농도 특성 분석 (Characteristics of Ozone Concentrations around an Urban Valley based on the Intensive Air Quality Measurement during Spring and Summer of 2006)

  • 송상근;김유근;강재은
    • 한국대기환경학회지
    • /
    • 제25권4호
    • /
    • pp.289-303
    • /
    • 2009
  • The chemical and meteorological effects on the concentration variations of ozone ($O_3$) were evaluated based on the intensive air quality measurement (5 pollutants and aromatic volatile organic compounds (AVOCs)) in and out-side an urban valley during spring and summer of 2006. The 5 pollutants measured in the study area include $O_3$, $NO_2$, NO, $PM_{10}$, and CO; the AVOCs include benzene (BEN), toluene (TOL), ethylbenzene (EB), m,p-xylene (MPX), and o-xylene (OX). For the purpose of this study, study areas were classified into two categories: valley area (VA) with a semi-closed topography covering a number of industrial complex, public building, and mountains and non-valley area (NVA) surrounding the suburban and residential areas. In general, the mean concentration levels of most pollutants (except for $PM_{10}$) in the VA were higher than those in the NVA. It was found that the average $O_3$ increase in the VA during spring might result from the combined effects such as the photochemical production from diverse anthropogenic sources and the $O_3$ accumulation due to geographical features (e.g., the semi-closed topography) and wind conditions (e.g., a low wind speed). In addition, the nocturnal $O_3$ increase in the VA during spring was primarily caused by local wind conditions (e.g., mountain and valley winds) with the low wind speed (approximately $1{\sim}2\;m\;s^{-1}$). On the other hand, the $O_3$ difference between the two areas during summer might be because of the photo-chemical production with the $O_3$ precursors (especially the AVOCs) rather than the contribution of wind conditions.

기류의 유입경로가 대관령 지역 안개의 화학조성에 미치는 영향 (Effect of Air-mass Back Trajectory on the Chemical Composition of Cloud/Fog Water at Daegwallyeong)

  • 김만구;이보경;김현진;홍영민
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.343-355
    • /
    • 2005
  • Cloud/fog water was collected at Daegwallyeong, a typical clean environmental area, by using an active fog sampler during the foggy period in 2002, The pH ranged from 3,7 to 6,5 with a mean of 5,0, but the pH calculated from average concentrations of $H^+$ was 4.4. $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ were predominant ions with average concentrations of 473,3, 463,3 and $576,0\;{\mu}eq/L$, respectively, This showed that cloud/fog water was slightly acidified, but the concentrations of major pollutants were as high as those for polluted area, suggesting effect from long range transported pollutants, Samples were categorized into four groups (E, W, S, N) by applying 48-h back trajectory analysis using the Hybrid Single-Particle Largrangian Integrated Trajectory (HYSPLIT) model. Concentrations of seasalt $(Na^+\;and\;Cl^-)$ were the highest for group E, indicating large input of seasalts by air masses transported from the East Sea. The concentrations of $SO_4^{2-}$ were slightly higher in group W but the difference was not significant. However, the concentrations of $NO_3^-$ were significantly higher in group W than those in other three groups, The median values of cloud/fog water pH for group N and W were below 4,5, which is significantly lower than median values in group E and group S, This suggests that the acidifying pollutants were transported from the Asia continents and Seoul metropolitan area cause acidification of the cloud/fog water in Daegwallyeong.