• Title/Summary/Keyword: the monitoring

Search Result 26,454, Processing Time 0.049 seconds

Current Status of Parents' Monitoring of and Level of Trust in School Lunch Programs (학부모의 학교급식 모니터링 현황 및 학교급식에 대한 신뢰도)

  • Hur, Boyoung;Choi, Injoo;Kim, Meeyoung;Kwon, Jinwook;Lee, Jiyoung;Yoon, Jihyun
    • Korean Journal of Community Nutrition
    • /
    • v.22 no.5
    • /
    • pp.401-412
    • /
    • 2017
  • Objectives: The purpose of this study was to investigate the current status of parents' monitoring of school lunch programs and to examine the relationship of parents' school lunch monitoring with their level of trust in school lunch programs. Methods: During November 2016, a web survey was conducted with 1,283 parents who had participated in monitoring of school lunch programs. A total of 621 parents completed the questionnaires (48.4% response rate) and the responses from 442 parents were analyzed (34.5% analysis rate) for elementary (n=196) and middle/high school parents (n=246), respectively. Results: Both the elementary and middle/high school parents most wanted to participate in monitoring 1~2 times per month, which was less frequent than their current practice. They showed the highest experience rate in 'food sanitation' area in both the prior training and actual practice of school lunch monitoring. They most responded 'increasing trust in school lunch programs' as a merit and 'lack of parents participating in monitoring' as a problem of school lunch monitoring. The average levels of trust did not differ between elementary and middle/high school parents. Multiple regression analyses showed that elementary school parents' level of satisfaction in the monitored school lunch programs was positively associated with the parents' level of trust in general school lunch programs. Monitoring frequency and parents' age, in addition to level of satisfaction in the monitored school lunch program, were associated with level of trust in general school lunch programs among middle/high school parents. Conclusions: There was room for change in parents' school lunch monitoring programs to meet parents' needs better. Well-managed school lunch monitoring programs contributing to parents' satisfaction with school lunch programs could increase parents' level of trust in school lunch programs.

Influences of Myo-monitoring on Masticatory Muscles (Myo-Monitoring이 저항근에 미치는 영향)

  • Kwang-Woo Lee;Woo-Cheon Kee;Sung-Su Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.89-103
    • /
    • 1989
  • In order to evaluate the influences of Myo-monitoring on masticatory muscles, Myo-monitoring on 31 normal persons and 30 persons with one more temporomandibular dysfunction symptoms during 45 minutes or above. The author observed velocities of mandibular opening and closing movement, variabilities of mandibular rest position and EMG activities of temporal and masseter muscles. The obtained results were as follows : 1. There were no significant differences on velocities of mandibular opening and closing movement between before and after Myo-monitoring. 2. There were significant differences on vertical dimension and total dimension form mandibular rest position to centric occlusion between before and after Myo-monitoring but no significant differences on anteroposterior and lateral dimension. 3. Activities of temporal and masseter muscles were decreased in Myo-Monitoring. 4. There were disappeared significant differences on EMG activity values between normal and symptom groups after myo-monitoring.

  • PDF

IFC-based Interperable information modeling of tunnel monitoring (상호운용성 확보를 위한 IFC 기반의 터널 계측 정보 모델링)

  • An, Hyun-Jung;Yi, Jin-Hoon;Kim, Hyo-Jin;Lee, Sang-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.613-616
    • /
    • 2008
  • This study presents an IFC-based information model for standardized and integrated information management system of tunnel monitoring. Information items of tunnel monitoring were extracted from the Tunnel Design Standard of Ministry of Construction and Transportation. Then, the information items were compared with components of IFC 2x Edition3 model. Two main entities are added into the IFC model for generic representing of monitoring devices and data. IfcMonitoringElement which is composed of IfcMonitoringLogger and IfcMonitorinSensor is proposed to represent physical information of data loggers and sensors, and relationship between data logger and sensors. Besides, as an additional resource of IFC model, IfcMonitoringData is provided to express measured data from sensors and warning histories.

  • PDF

Current Status of Intracranial Pressure Monitoring in Patients with Severe Traumatic Brain Injury in Korea : A Post Hoc Analysis of Korea Neurotrauma Databank Project with a Nationwide Survey

  • Youngheon Lee;Jung Hwan Lee;Hyuk Jin Choi;Byung Chul Kim;Seunghan Yu;Mahnjeong Ha;The KNTDB Investigators
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.5
    • /
    • pp.543-551
    • /
    • 2023
  • Objective : This study aimed to investigate the current status of intracranial pressure (ICP) monitoring in patients with severe traumatic brain injury (sTBI) in Korea and the association between ICP monitoring and prognosis. In addition, a survey was administered to Korean neurosurgeons to investigate the perception of ICP monitoring in patients with sTBI. Methods : This study used data from the second Korea Neurotrauma Databank. Among the enrolled patients with sTBI, the following available clinical data were analyzed in 912 patients : Glasgow coma scale score on admission, ICP monitoring, mortality, and extended Glasgow outcome scale score at 6 months. In addition, we administered a survey, entitled "current status and perception of ICP monitoring in Korean patients with sTBI" to 399 neurosurgeons who were interested in traumatic brain injury. Results : Among the 912 patients, 79 patients (8.7%) underwent ICP monitoring. The mortality and favorable outcome were compared between the groups with and without ICP monitoring, and no statistically significant results were found. Regarding the survey, there were 61 respondents. Among them, 70.4% of neurosurgeons responded negatively to performing ICP monitoring after craniectomy/craniotomy, while 96.7% of neurosurgeons responded negatively to performing ICP monitoring when craniectomy/craniotomy was not conducted. The reasons why ICP monitoring was not performed were investigated, and most respondents answered that there were no actual guidelines or experiences with post-operative ICP monitoring for craniectomy/craniotomy. However, in cases wherein craniectomy/craniotomy was not performed, most respondents answered that ICP monitoring was not helpful, as other signs were comparatively more important. Conclusion : The proportion of performing ICP monitoring in patients with sTBI was low in Korea. The outcome and mortality were compared between the patient groups with and without ICP monitoring, and no statistically significant differences were noted in prognosis between these groups. Further, the survey showed that ICP monitoring in patients with sTBI was somewhat negatively recognized in Korea.

An Exploration of the Experiences in Childcare Experts, Parents, and Directors with Participation in 'Daycare Centers Monitoring Program' ('어린이집 부모모니터링 사업'에 참여한 보육전문가, 부모 및 원장의 경험 탐색)

  • Kyun, Ju Youn
    • Korean Journal of Childcare and Education
    • /
    • v.13 no.3
    • /
    • pp.19-38
    • /
    • 2017
  • Objective: The purpose of this study is to examine the practical experiences of childcare experts, parents, and daycare center directors who participated in the 'Daycare Centers Monitoring Program' carried out in K city. Methods: Participants were three childcare experts who belong to the monitoring group in K city, three mothers with infants and children, and three daycare center directors who were selected for the 'Daycare Centers Monitoring Program'. Results: As a result of the research, the childcare experts experienced the following; 1) sharing interesting experiences with parents, 2) a perception of the monitoring program for taking advantage of mutual strengths, 3) the opportunity of maintaining a sense of presence in early childhood education institutions, et al. The mothers' experiences were shown to include, 1) resolving small questions about the operation and management of a daycare center, 2) feelings of relief through observing the life style of infants and children, 3) the joy and reward of being a member of the monitoring group, et al. The directors' experiences were indicated to include 1) a psychological discomfort recognized as a target of the daycare monitoring and as 'another evaluation', 2) the confusion caused by different reviews, 3) an ambiguity on the unfamiliar indexes and contents electronically documented, et al. Conclusion/Implications: Based on these results, there was a discussion about actual suggestions and educational implications on the daycare monitoring program in order to improve the quality of daycare services in childcare centers.

Wireless structural health monitoring of stay cables under two consecutive typhoons

  • Kim, Jeong-Tae;Huynh, Thanh-Canh;Lee, So-Young
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.47-67
    • /
    • 2014
  • This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

Wearable and Implantable Sensors for Cardiovascular Monitoring: A Review

  • Jazba Asad;Jawwad Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.171-185
    • /
    • 2023
  • The cardiovascular syndrome is the dominant reason for death and the number of deaths due to this syndrome has greatly increased recently. Regular cardiac monitoring is crucial in controlling heart parameters, particularly for initial examination and precautions. The quantity of cardiac patients is rising each day and it would increase the load of work for doctors/nurses in handling the patients' situation. Hence, it needed a solution that might benefit doctors/nurses in monitoring the improvement of the health condition of patients in real-time and likewise assure decreasing medical treatment expenses. Regular heart monitoring via wireless body area networks (WBANs) including implantable and wearable medical devices is contemplated as a life-changing technique for medical assistance. This article focuses on the latest development in wearable and implantable devices for cardiovascular monitoring. First, we go through the wearable devices for the electrocardiogram (ECG) monitoring. Then, we reviewed the implantable devices for Blood Pressure (BP) monitoring. Subsequently, the evaluation of leading wearable and implantable sensors for heart monitoring mentioned over the previous six years, the current article provides uncertain direction concerning the description of diagnostic effectiveness, thus intending on making discussion in the technical communal to permit aimed at the formation of well-designed techniques. The article is concluded by debating several technical issues in wearable and implantable technology and their possible potential solutions for conquering these challenges.

Earthquake Observation through Groundwater Monitoring: A case of M4.9 Odaesan Earthquake (지하수 모니터링을 통한 지진 감시 가능성: 중규모(M4.9) 오대산 지진의 관측)

  • Lee, Hyun-A;Kim, Min-Hyung;Hong, Tae-Kyung;Woo, Nam-C.
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.3
    • /
    • pp.38-47
    • /
    • 2011
  • Groundwater monitoring data from the National Groundwater Monitoring Stations, a total of 320 stations, were analyzed to identify the response of water level and quality to the Odaesan earthquake (M4.9) occurred in January 2007. Among the total of eight stations responded to the earthquake, five wells showed water-level decline, and in three wells, water level rose. In terms of recovery, water levels in four stations had recovered to the original level in five days, but not in the rest four wells. The magnitude of water-level change shows weak relations to the distance between the earthquake epicenter and the groundwater monitoring station. However, the relations to the transmissivities of monitored aquifer in the station with the groundwater change were not significant. To implement the earthquake monitoring system through the groundwater monitoring network, we still need to accumulate the long-term monitoring data and geostatistically analyze those with hydrogeological and tectonic factors.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Development of Tire Lateral Force Monitoring Systems Using Nonlinear Observers (비선형 관측기를 이용한 차량의 타이어 횡력 감지시스템 개발)

  • 김준영;허건수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.169-176
    • /
    • 2000
  • Longitudinal and lateral forces acting on tires are known to be closely related to the tract-ability braking characteristics handling stability and maneuverability of ground vehicles. In thie paper in order to develop tire force monitoring systems a monitoring model is proposed utilizing not only the vehicle dynamics but also the roll motion. Based on the monitoring model three monitoring systems are developed to estimate the tire force acting on each tire. Two monitoring systems are designed utilizing the conventional estimation techniques such as SMO(Sliding Mode Observer) and EKF(Extended Kalman Filter). An additional monitoring system is designed based on a new SKFMEC(Scaled Kalman Filter with Model Error Compensator) technique which is developed to improve the performance of EKF method. Tire force estimation performance of the three monitoring systems is compared in the Matlab simulations where true tire force data is generated from a 14 DOF vehicle model with the combined-slip Magic Formula tire model. The built in our Lab. simulation results show that the SKFMEC method gives the best performance when the driving and road conditions are perturbed.

  • PDF