• Title/Summary/Keyword: the monitoring

Search Result 26,605, Processing Time 0.049 seconds

Ubiquitous Computing Technology Based Environmental Monitoring and Diagnosis System : Architecture and Case Study (유비쿼터스 컴퓨팅 기술 기반 환경 모니터링/진단 시스템의 아키텍처 및 사례 연구)

  • Yoon, Joo-Sung;Hwang, Jung-Min;Suh, Suk-Hwan;Lee, Chang-Min
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.4
    • /
    • pp.230-242
    • /
    • 2010
  • In this paper, an environmental monitoring and diagnosis system based on ubiquitous computing technology, shortly u-Eco Monitoring System, is proposed. u-Eco Monitoring System is designed to: 1) Collect information from the manufacturing processes via ubiquitous computing technology, 2) Analyze the current status, 3) Identify the cause of problem if detected by rule-based and case-based reasoning, and 4) Provide the results to the operator for proper decision making. Based on functional modeling, a generic architecture is derived, followed by application to a manufacturing system in iron and steel making industry. Finally, to show the validity of the proposed method, a prototype is developed and tested. The developed methods can be used as a conceptual framework for designing environmental monitoring and diagnosis system for industrial practices by which monitoring accuracy and response time for abnormal status can be significantly enhanced, and relieving operator pressure from manual monitoring and error-prone decision making.

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers (수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구)

  • 우정현;김선태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

Structural performance monitoring of an urban footbridge

  • Xi, P.S.;Ye, X.W.;Jin, T.;Chen, B.
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.129-150
    • /
    • 2018
  • This paper presents the structural performance monitoring of an urban footbridge located in Hangzhou, China. The structural health monitoring (SHM) system is designed and implemented for the footbridge to monitor the structural responses of the footbridge and to ensure the structural safety during the period of operation. The monitoring data of stress and displacement measured by the fiber Bragg grating (FBG)-based sensors installed at the critical locations are used to analyze and assess the operation performance of the footbridge. A linear regression method is applied to separate the temperature effect from the stress monitoring data measured by the FBG-based strain sensors. In addition, the static vertical displacement of the footbridge measured by the FBG-based hydrostatic level gauges are presented and compared with the dynamic displacement remotely measured by a machine vision-based measurement system. Based on the examination of the monitored stress and displacement data, the structural safety evaluation is executed in combination with the defined condition index.

Legal Issues and Challenges of National Curriculum Monitoring Group (국가교육과정 모니터링단의 법적 문제와 과제)

  • Park, Changun
    • Journal of the International Relations & Interdisciplinary Education
    • /
    • v.4 no.2
    • /
    • pp.21-41
    • /
    • 2024
  • The The purpose of this study is to find the legal regulations of the National Education process monitoring team and challenges.The research method was used for literature research, and method of counseling, and methods.literature study used for national education process monitoring terminals related laws and status analysis, and legal interpretation was used for national education process monitoring related to the system and logic organize the system and logic of national education process monitoring.The interview was used directly and indirectly used to reduce errors in the development of law experts from the development of law and educational experts.The main contents of research was examined based on the need of legal nature and system based on the need of legal characteristics and system.Next, it was evaluated on the operation of the national education process monitoring team, and tasks based on these evaluation results. The results of discussion was presented separately divided into the issue of the Enforcement Decree of the Act, task, and the problem of the Enforcement Decree. The problem of the Enforcement Decree of the Act was discussed on the obligation of the purpose of the purpose of the purpose of the establishment, monitoring unit, monitoring unit and role of the compliance organization.The problem and tasks were discussed with negative synthesis of monitoring and monitoring complex definition of the qualification criteria for representativeity, monitoring range of monitoring and monitoring range of monitoring.As a result of these discussion, the reorganization and operation of the organization was requested to establish a special profit group based on expertise, there were room for special profit groups based on expertise.

A Power Quality Monitoring of The Grid-connected Wind Turbine in Daegwallyeong Test Site (계통 연계 대관령 풍력실증단지에서의 전력 품질 모니터링)

  • Kwon H. J.;Kim K. H.;Jang S. I.;Yoo N. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1513-1515
    • /
    • 2004
  • This paper describe the power quality monitoring results of the grid-connected wind turbine generator in Daegwallyeong Test Site. The power quality monitoring for grid-connected wind turbine generators are important to verify their performance as the grid-connected generators. In order to measure the impacts on the grid of wind turbine generator and evaluate the performance by analyzing electrical parameters, we equipped the power quality monitoring system in the real field of the Daegwallyeong test site. The developed monitoring system gathers information by remote access through the internet. The monitoring results and the detail explanation for the developed wind turbine monitoring system is presented in the study.

  • PDF

Risk identification, assessment and monitoring design of high cutting loess slope in heavy haul railway

  • Zhang, Qian;Gao, Yang;Zhang, Hai-xia;Xu, Fei;Li, Feng
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.67-78
    • /
    • 2018
  • The stability of cutting slope influences the safety of railway operation, and how to identify the stability of the slope quickly and determine the rational monitoring plan is a pressing problem at present. In this study, the attribute recognition model of risk assessment for high cutting slope stability in the heavy haul railway is established based on attribute mathematics theory, followed by the consequent monitoring scheme design. Firstly, based on comprehensive analysis on the risk factors of heavy haul railway loess slope, collapsibility, tectonic feature, slope shape, rainfall, vegetation conditions, train speed are selected as the indexes of the risk assessment, and the grading criteria of each index is established. Meanwhile, the weights of the assessment indexes are determined by AHP judgment matrix. Secondly, The attribute measurement functions are given to compute attribute measurement of single index and synthetic attribute, and the attribute recognition model was used to assess the risk of a typical heavy haul railway loess slope, Finally, according to the risk assessment results, the monitoring content and method of this loess slope were determined to avoid geological disasters and ensure the security of the railway infrastructure. This attribute identification- risk assessment- monitoring design mode could provide an effective way for the risk assessment and control of heavy haul railway in the loess plateau.

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap (유리 공장 피판술 후 외부 감시 피판의 유용성)

  • Kim, Baek Kyu;Chang, Hak;Minn, Kyung Won;Hong, Joon Pio;Koh, Kyung Suck
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

Showerhead Surface Temperature Monitoring Method of PE-CVD Equipment (PE-CVD 장비의 샤워헤드 표면 온도 모니터링 방법)

  • Wang, Hyun-Chul;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.16-21
    • /
    • 2020
  • How accurately reproducible energy is delivered to the wafer in the process of making thin films using PE-CVD (Plasma enhanced chemical vapor deposition) during the semiconductor process. This is the most important technique, and most of the reaction on the wafer surface is made by thermal energy. In this study, we studied the method of monitoring the change of thermal energy transferred to the wafer surface by monitoring the temperature change according to the change of the thin film formed on the showerhead facing the wafer. Through this research, we could confirm the monitoring of wafer thin-film which is changed due to abnormal operation and accumulation of equipment, and we can expect improvement of semiconductor quality and yield through process reproducibility and equipment status by real-time monitoring of problem of deposition process equipment performance.

Simulation Studies on Monitoring System for Interconnection of Distibuted Generation to Power Grid (분산전원 계통 연계 상황 모니터링을 위한 시뮬레이션 연구)

  • Oh, Sung-Nam;Han, Chul-Wan;Yoon, Ki-Don;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.96-98
    • /
    • 2005
  • This paper describes a monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop and operate a physical monitoring system, we constitute a simulation device to simulate the monitoring processes for the situations. The simulation system consists of the server and the client that connected by communication line. This system has various functions to monitor the power quality and the connection situation. Those functions are generation, transmission, acquisition and analysis of the simulated power data. This research seems very important to get the reliable and intelligent connection algorithm through the result of simulated monitoring system. Also hereafter, as this system uses the remote monitoring system through network and constitute the data base(DB), it will play an important role in building the automation of power system efficiently and systematically.

  • PDF