• Title/Summary/Keyword: the lowest temperature

Search Result 2,270, Processing Time 0.032 seconds

Effects of Composition Ratio and Temperature on Friction and Wear of PTFE-Polyimide Composites (PTFE-폴리이미드 복합 재료의 마찰과 마모에 대한 성분비와 온도의 영향)

  • 심현해;권오관;이규한;김병환
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.55-62
    • /
    • 1996
  • Present study was undertaken to investigate the effects of composition ratio and temperature on the friction and wear of PTFE-polyimide composites under the atmosphere of nitrogen gas. The load range was 0.62-3.46 MPa, and the temperature range was room temperature and 200$^{\circ}$C. To mention some of the notable results, friction coefficient of PTFE 100% varied relatively little within the given load and temperature ranges. Polyimide 100% showed the lowest friction coefficient of 0.06 at 200$^{\circ}$C among all the experiments. PTFE 80%-polyimide 20% showed the lowest wear factors on the whole. Friction coefficient of PTFE 20%-polyimide 80% varied from the highest 0.35 to the lowest 0.09 among all the materials at room temperature, and showed almost the same lowest values with polyimide 100% at 200$^{\circ}$C. Suggestion of friction and wear mechanisms of the materials was tried to explain the observed phenomena including above mentioned results.

Dependence of Physical, and Electrical Properties of $CaTiO_3$ on Sintering Temperature and Composition ($CaTiO_3$ 유전 재료의 소결온도와 조성변화에 따른 물리적 및 전기적 특성 변화)

  • 우성수;안영수;한문희;노광수
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.10
    • /
    • pp.1111-1116
    • /
    • 1995
  • To use dielectric material of high power multilayer capacitor, the composition of the commercial CaTiO3 was changed to decrease the sintering temperature, and the physical and electrical properties were investigated. Series of experiments showed that CaTiO3 with sintering additives had the highest density, the highest shrinkage, the lowest dielectric constant, the lowest loss factor, and the lowest temperature coefficient of capacitance (TCC). These properties had the constant values at sintering temperature of above 120$0^{\circ}C$.

  • PDF

On the Characteristics of Globe Temperature Variation Observed at Downtown in Summer Season (하계에 도심지에서 관측된 흑구온도의 특성 분석)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Park, Gil-Un
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.907-918
    • /
    • 2008
  • In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.

Experimental Study on the Effective Temperature Calculation of Concrete Box Girder Bridge (콘크리트 박스거더교의 설계 유효온도 산정을 위한 실험적 연구)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.740-745
    • /
    • 2020
  • To calculate the reasonable design temperature load of a concrete box girder bridge, one bridge test specimen was made. The temperature gauges installed on the bridge test specimen measured 48 sets of temperature per day at 30-minute intervals during the summer and winter periods of one year. The temperature measured at each station was treated statistically to calculate the trend line and standard error, and the temperature distribution and trend line at the representative station were presented. The maximum effective temperature and the lowest effective temperature were calculated from the air temperature suggested by Euro code. The maximum effective temperature was calculated to be 1.5 to 2℃ higher than the Euro code at 35℃ and above. In comparison, the lowest effective temperature was 0.5 to 1.1℃ lower at -13℃ to-19℃. Compared to the effective temperature of this study according to the highest and lowest 50-year frequency of the Yangsan region, the highest effective temperature was 4.7℃ higher, and the lowest effective temperature was 4.5℃ lower. Considering the increasing climate change and reflecting the results of this analysis, it is deemed necessary to make the current temperature design standards larger.

Effects of temperature and salinity on egg development and larval settlement of an invasive ascidian species, Herdmania momus (Savigny, 1816)

  • Park, Juun;Lee, Yun-Sik;Kim, Donghyun;Shin, Sook
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.4
    • /
    • pp.625-633
    • /
    • 2020
  • The effects of temperature and salinity on egg development and settlement of the ascidian Herdmania momus were investigated. Adult specimens were collected from the Dodu Yacht facility in Jeju Island, Korea(33°30'30.54"N, 126°27'55.46"E) in August 2018. Egg development and larval settlement were observed and recorded at 8 h intervals using a stereomicroscope, under nine temperature (10, 13, 16, 19, 22, 25, 28, 31, and 34℃), and four salinity regimens (28, 30, 32, and 34 psu). The highest hatching rate (82.8±7%) was observed at 32 psu and 25℃ and the lowest hatching rate (1.0±2%) was at 34 psu and 13℃. The developmental rate (0.222±0.0994) was highest at 28 psu and 28℃, and lowest (0.016±0.008) at 30 psu and 13℃. The highest settlement success rate (77.1±5%) was at 32psu and 25℃ and the lowest(0.1±1.0%) was at 30psu, and 13℃. The rate of settlement(0.080±0.000) was highest at 28psu and 28℃, and lowest(0.013±0.000) at 30psu and 13℃. Both hatching and settlement success rates increased as temperature increased and tended to decrease beyond an optimal temperature range. Herdmania momus preferred 30-34 psu salinity and 22-25℃ temperature. This study provides baseline information about the life history of H. momus, and important data to control the damage caused by the increase in number and distribution of this invasive ascidian.

Study on Control of Thermal Environmental Factors for Improvement of Productivity of Laying Hens in Summer (여름철 산란계사 내 열환경인자 중 제어요소에 관한 연구)

  • Kim, Seong-Wan;Lee, Tae-Hoon;Cha, Gwang-Jun;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.53 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • This study carried out to determine control factors for the improvement of productivity of laying hens suffering heat stress during hot weather. A total of 48,451 ISA Brown layers were housed in a farm located in Gyeongsangnam-do, Republic of Korea. Five thermo-hydrometer loggers were installed inside the house to collect data of dry-bulb temperature and relative humidity. The experiment continued for 81 days when the summer season begins from 19th June to 7th September, 2018. This study analyzed the correlations among layers' production index and daily average, highest, and lowest temperature; daily average, highest, and lowest relative humidity; and daily average, minimum, and maximum THI. The result indicated that feed consumption, hen-day egg production, egg weight, and FCR decreased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.01). On the other hand, water intake increased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.001). The relative humidity was not considered to have direct correlations to the layers' production index (p>0.05). However, it was noticeable that the mortality did not have significant relations with daily average and highest temperature; THI; or daily average, highest and lowest relative humidity while it was relevant to the daily lowest temperature and THI (p<0.05). In conclusion, to enhance the productivity of laying hens in a hot climate, it is recommended that daily average, highest, and lowest dry-bulb temperature and THI are maintained as low as possible. Especially, the daily lowest temperature is needed to lower to 20℃, which is the lowest critical temperature for layers.

Changes of Myocardial Temperature Following Infusion of Cold Cardioplegic Solution in Open Heart Surgery (개심술에서 냉각 심정지액 주입에 따른 심근온도의 변화)

  • 임승우
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.345-351
    • /
    • 1991
  • The myocardial temperature was monitored in 19 patients of open heart surgery using the Shiley myocardial temperature probe in Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. The myocardial temperature were measured time-wise: initial and 15 minutes following the infusion of the cardioplegic solution into the aortic root and upon reinfusion, which is 30 minutes apart from the initial. The measurements were made in the anterior wall of the right ventricle, the posterior wall of the left ventricle and the interventricular septum. Immediately after initial infusion, the temperature of the right ventricle[10.7 $\pm$4.3oC] was the lowest and that of the left ventricle[12.9$\pm$3.9 oC] the highest in the mean values among all 19 patients. However, no significant differences were noted among the different regions. At 15 minutes after infusion, the lowest temperature was in the right ventricle[17.5$\pm$5.1 oC], followed by interventricular septum[17.9$\pm$2.9 oC], and left ventricle[21.4$\pm$2.5 oC]. At 30 minutes after infusion, the lowest temperature was measured in the interventricular septum[13.6$\pm$2.7 oC ], followed by right ventricle[13.8$\pm$4.0 oC] and left ventricle[14.5$\pm$4.5 oC ]. Evaluating changes of myocardial temperature according to postinfusion time, the temperature at 15 minutes after infusion showed significant increase as compared with that immediately after the infusion in all three regions[p<0.05] and the temperature at 30 minutes after infusion showed significant decrease as compared with that at 15 minutes after the infusion in the left ventricle and the interventricular septum[p<0.05]. The left ventricle was rewarmed most rapidly and its temperature the highest in the mean values, Accordingly, the maintenance of optimal hypothermia of the left ventricle indicated a very careful factor in myocardial protection.

  • PDF

Temperature Reduction Effect According to Light Transmittance of Urban Street Trees - Focused on Seocho-gu in Seoul - (도시 내 가로수의 광선투과량에 따른 온도저감 효과 - 서울시 서초구를 중심으로 -)

  • Kim, Eun-Bum;Kim, Nam-Choon;Shin, Ji-Hoon;Song, Won-Kyeong;Kim, Do-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.3
    • /
    • pp.45-54
    • /
    • 2017
  • With rapid urbanization and reckless urban development in the 21st century, the urban environment has gradually gotten worse, and urban heat island effect has been dramatically intensified. Thus, the importance of street greenery that can mitigate the urban heat island effect has further been highlighted. In this regard, this study was aimed at selecting suitable plant species for street greenery to reduce the urban heat island effect. Towards this end, five roads located in Seocho-gu, Seoul were selected as study sites, and plant species composition and difference of surface temperature were compared and analyzed in relation to the light transmittance. The street with the greatest temperature difference is Bangbae-ro(Platanus occidentalis). On the other hand, the road with the lowest temperature difference is Nambusunhwan-doro(Metasequoia Glyptostroboides). The effect of temperature reduction was found to be associated with light transmittance.Bangbae-ro(Platanus occidentalis) with the lowest light transmittance showed the highest temperature difference and Nambusunhwan-doro(Metasequoia Glyptostroboides) with the highest light transmittance showed the lowest temperature difference. It is analyzed that there are most differences in temperature when the amount of lights coming in between the crown is small. The temperature reduction effect can be obtained by planting deciduous broad-leaved trees. Also species with dense crown and broad width of crown will be able to maximize the effect of temperature reduction. In future studies, it will be necessary to expand the other species of trees in the street, and analyze the germicidal trees and shrubs as well as the differences in the packaging materials.

Standardization Study of Thermal Imaging using the Acupoints in Human Body (적외선 체열 영상의 표준화 연구 부위별 대표 혈위를 중심으로)

  • Choi, Young-Chon;Lim, Chung-San;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.113-122
    • /
    • 2008
  • Objective: The purpose of this study was to invigorate the use of infrared thermal imaging apparatus as a diagnostic tool in Oriental medicine by providing standard temperature on specific acupoints. Methods: Subjects for the study was recruited through an advertisement in the school homepage(www.sangji.ac.kr) explaining the objectives and methods. 100 volunteers agreeing to terms were selected and measured the full body thermal image. Common acupoints used in the clinical surrounding were chosen and final 63 acupoints were selected for the measurement. Male/female and right/left readings were obtained for the analysis. Results: Following results were obtained from analyzing the body temperature of 50 male subjects and 50 female subjects 1. Subjects participating in the study ranged from 19 years of age to 44 years. Median male age at $26.86{\pm}6.02$ and female age at $22.88{\pm}2.74$, respectively. 2. For all acupoints, no significant differences were witnessed between the gender and right, left side of the body. 3. 10 acupoints from the facial region(18 bilateral), 8 acupoints from the chest/abdomen region(10 bilateral), 6 acupoints from the back region(11 bilateral), 17 acupoints from the upper extremity(34 bilateral), and 22 acupoints from the lower extremity(44 bilateral) were chosen. 4. In the facial region, BL2 showed the highest temperature and GV26 showed the lowest. 5. In the chest/abdomen region, CV22 showed the highest temperature and CV6 showed the lowest. 6. In the back region, GV14 showed the highest temperature and BL23 showed the lowest. 7. In the upper extremity region, jianqian(extra point) showed the highest temperature and baxie(extra point) showed the lowest. 8. In the lower extremity region, KI1 and bafeng(extra point) shoed the highest temperature and BL40 showed the lowest. Conclusions: Based on the standard body temperature measured on specific acupoints throughout the body, we hope these findings can trigger further studies on applications of infrared thermal imaging and clinical usage in the field of oriental medicine.

Effect of Carbon and Nickel on Microstructure and Low Temperature Charpy Impact Properties of HSLA Steels (HSLA 강의 미세조직과 저온 샤르피 충격 특성에 미치는 탄소와 니켈의 영향)

  • Eom, Haewon;Cho, Sung Kyu;Cho, Young Wook;Shin, Gunchul;Kwon, Yongjai;Lee, Jung Gu;Shin, Sang Yong
    • Korean Journal of Materials Research
    • /
    • v.30 no.4
    • /
    • pp.184-196
    • /
    • 2020
  • In this study, effects of carbon and nickel on microstructure and low temperature Charpy impact properties of HSLA (high strength low alloy) steels are investigated. To understand the complex phase transformation behavior of HSLA steels with high strength and toughness before and after welding processes, three kinds of HSLA steels are fabricated by varying the carbon and nickel content. Microstructure analysis, low temperature Charpy impact test, and Vickers hardness test are performed for the base metals and CGHAZ (coarse-grain heat affected zone) specimens. The specimens with the lowest carbon and nickel content have the highest volume fraction of AF, the lowest volume fraction of GB, and the smallest GB packet size. So, the low temperature Charpy absorbed energy of the CGHAZ specimen is the highest. The specimens with increased carbon and nickel content have the lowest volume fraction of AF, the highest volume fraction of GB, and the largest GB packet size. So, the low temperature Charpy absorbed energy of the CGHAZ specimen is the lowest.