• Title/Summary/Keyword: the influence of wind

Search Result 887, Processing Time 0.028 seconds

Couette-Poiseuille flow based non-linear flow over a square cylinder near plane wall

  • Bhatt, Rajesh;Maiti, Dilip K.;Alam, Md. Mahbub;Rehman, S.
    • Wind and Structures
    • /
    • v.26 no.5
    • /
    • pp.331-341
    • /
    • 2018
  • A numerical study on the flow over a square cylinder in the vicinity of a wall is conducted for different Couette-Poiseuille-based non-uniform flow with the non-dimensional pressure gradient P varying from 0 to 5. The non-dimensional gap ratio L (=$H^{\ast}/a^{\ast}$) is changed from 0.1 to 2, where $H^{\ast}$ is gap height between the cylinder and wall, and $a^{\ast}$ is the cylinder width. The governing equations are solved numerically through finite volume method based on SIMPLE algorithm on a staggered grid system. Both P and L have a substantial influence on the flow structure, time-mean drag coefficient ${\bar{C}}_D$, fluctuating (rms) lift coefficient ($C_L{^{\prime}}$), and Strouhal number St. The changes in P and L leads to four distinct flow regimes (I, II, III and IV). Following the flow structure change, the ${\bar{C}}_D$, $C_L{^{\prime}}$, and St all vary greatly with the change in L and/or P. The ${\bar{C}}_D$ and $C_L{^{\prime}}$ both grow with increasing P and/or L. The St increases with P for a given L, being less sensitive to L for a smaller P (< 2) and more sensitive to L for a larger P (> 2). A strong relationship is observed between the flow regimes and the values of ${\bar{C}}_D$, $C_L{^{\prime}}$ and St. An increase in P affects the pressure distribution more on the top surface than on bottom surface while an increase in L does the opposite.

Photo-Sensorless Solar Tracking System based on Modular Structure and IoT Technology (모듈화 구조와 IoT 기반의 광센서리스 태양광 추적 시스템)

  • Kim, Dae-Won;Kim, Jeong-Tae;Chung, Gyo-Bum
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.392-402
    • /
    • 2020
  • This paper proposes a solar tracking system without photo-sensors. The system can be classified into four modules: Solar Tracking, MPPT, ESS, and Real-Time Monitoring. Nine solar panels, as a basic unit, are adopted with grid structures of different heights to reduce wind influence and to enable solar tracking without photo-sensors. The low-cost MCU implements MPPT method which generates PWM switching signal for boost converter. The unit of ESS consists of three-series and four-parallel lithium-ion batteries in order to enable monitoring for abnormalities in temperature and electrical characteristics of battery. Four MCUs used in the system consists of two AVR Atmega128, and two Raspberry PI, and they exchanges operation informations. Experimental results of the proposed system show the solar tracking performance, the possibility of on-site and remote monitoring and the convenience of maintenance based on IoT technology.

Seasonal Variations of Water Quality in the Coastal Sea of Jungmun Resort Complex in Jeiu Island (제주도 중문관광단지 연안해역 수질의 계절변동)

  • Jang Seung-Min;Choi Young-Chan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.3-18
    • /
    • 2002
  • This study has been carried out to find the water Quality in coastal sea of fungmun area, southern Jeju Island. In-situ observations and water sampling had been made every month from July 1997 to June 2000. The distributions of water temperature and salinity over the study area have been 13.8~27.0℃ and 30.0~34.7‰, respectively. Salinity is showed low salinity from June to September (rainy season) because of rain. Tsushima Warm Waters (TWW) as ≥15℃ and ≥34‰ influence the adjacent sea around Jeju Island all year round. Yangtse Coastal Waters (YCW) influence the surface layer around Jeju from June to September and so strong stratification (termocline, halocline) resulted at the depth of between 20~30m at outer-sea. However the stratification does not happen even in summer at inner-sea, which seem to be caused due to vertical mixing by wind, waves and tides. A water mass of high value of water temperature and salinity (respectively 14.1~17.7℃, 33.9~34.1‰) stayed at the lower layer in outer-sea all the year round. It is probably formed by mixing between TWW and YSBCW(Yellow Sea Bottom Cold Water). The mean value of DO was the lowest in summer and the highest in winter. COD and TH were the highest in summer and the lowest in winter. However, TP showed the lowest value in summer season, because the mean value of N/P ratio was over 16. The mean of N/P ratio was under 16 in other seasons. The phosphate would be a limiting factor in the growth of phytoplanHon in summer. Nitrate would be a limiting factor in other seasons. Distribution of chlorophyll a did not show any seasonal change in the study period, but especially increased during April and May in the first year(1998) and the second year(1999) all over the study area, which suggested that phytoplankton inhabitation distributed widely in the study area. The space averaged values were the highest for TIN in rainy season and lower for TP in rainy season than in other seasons. It suggests that river runoff influences the inner-sea.

  • PDF

Spatial and Temporal Variability of Significant Wave Height and Wave Direction in the Yellow Sea and East China Sea (황해와 동중국해에서의 유의파고와 파향의 시공간 변동성)

  • Hye-Jin Woo;Kyung-Ae Park;Kwang-Young Jeong;Do-Seong Byun;Hyun-Ju Oh
    • Journal of the Korean earth science society
    • /
    • v.44 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • Oceanic wind waves have been recognized as one of the important indicators of global warming and climate change. It is necessary to study the spatial and temporal variability of significant wave height (SWH) and wave direction in the Yellow Sea and a part of the East China Sea, which is directly affected by the East Asian monsoon and climate change. In this study, the spatial and temporal variability including seasonal and interannual variability of SWH and wave direction in the Yellow Sea and East China Sea were analyzed using European Center for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5) data. Prior to analyzing the variability of SWH and wave direction using the model reanalysis, the accuracy was verified through comparison with SWH and wave direction measurements from Ieodo Ocean Science Station (I-ORS). The mean SWH ranged from 0.3 to 1.6 m, and was higher in the south than in the north and higher in the center of the Yellow Sea than in the coast. The standard deviation of the SWH also showed a pattern similar to the mean. In the Yellow Sea, SWH and wave direction showed clear seasonal variability. SWH was generally highest in winter and lowest in late spring or early summer. Due to the influence of the monsoon, the wave direction propagated mainly to the south in winter and to the north in summer. The seasonal variability of SWH showed predominant interannual variability with strong variability of annual amplitudes due to the influence of typhoons in summer.

Some biological notes on Eriophyes kuko KISHIDA (1) Its biology and life history (구기자 혹응애(Eriophyes kuko KISHIDA)에 관한 생태학적 지견 (1) 그의 생태 및 생활사)

  • Kim C. H.
    • Korean journal of applied entomology
    • /
    • v.5_6
    • /
    • pp.59-63
    • /
    • 1968
  • This Paper deals With the biology and the life Cycle of Eriophyes kuko KISHIDA. 1. The host of Eriophyes kuko KISHIDA is Lycium chinense MILL (Boxthorn), Solanum nigrum LINNE(Morel) and Capacium annum LINNE(Red pepper) etc. 2. Eriophyes kuko KISHIDA is migrated and propagated by physical carriers. The direction of the wind has a great influence upon migration and dispersal. 3. The number of e99s deposited by a adult female is $28.5\pm0.449$ egg period is $7.0\pm0.447$ and larval period is $4.33\pm0.667$ days respectively. 4. The size of gall diameter on the leaf of Lycium Chinense MILL after boring in each date by Eriophyes kuke KISHIDA is as follows, 1st day after boring is $290.5\pm0.3415\mu$ End 25st day after boring is $3260.5\pm0.5157\mu$ in average. 5. Adult periods are from 25 to 30 days and the egg laying period is 6 days. 6. Eriophyes kuko KISHIDA has 6 to 7 generations in a year, and hibernate they over winter in the gall as an adult. The first adult appears in late May.

  • PDF

Analysis of the Damaged Range Caused by LPG Leakage and Vapor Clouds Considering the Cold Air Flow (찬공기 흐름을 고려한 LPG 누출 및 증기운에 의한 피해 영향 범위 분석)

  • Gu, Yun-Jeong;Song, Bonggeun;Lee, Wonhee;Song, Byunghun;Shin, Junho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.27-35
    • /
    • 2022
  • When LPG leaks from the storage tank, the gas try to sink to the ground because LPG is heavier than air. The gas easily creates vapor clouds causing aggressive accidents in no airflow. Therefore, It is important to prevent in advance by analyzing the damaged range caused from LPG leakage and vapor clouds. So, this study analyzed the range of damaged by LPG leakage and vapor clouds with consideration of the cold air flow which is generated by the topographical characteristics and the land use status at night time in the Jeju Hagari. As a result of the cold air flow using KLAM_21, about 2 m/s of cold air was introduced in from the southeast due to the influence of the terrain. The range of damaged by LPG leakage and vapor cloud was analyzed using ALOHA. When the leak hole size is 10 cm at the wind speed of 2 m/s, the range corresponding to LEL 60 % (12,600 ppm) was 61 m which range is expected to influence in nearby residential areas. These results of this study can be used as basic data to prepare preventive measures of accidents caused by vapor cloud. Forward, it is necessary to apply CFD modeling such as FLACS to check the vapor cloud formation due to LPG leakage in a relatively narrow area and to check the cause analysis.

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.

Effect of Risk Perception of Horticultural Facility Farmers on the Purchase Intention Insurance -Focusing on Jeju island - (원예시설 농가의 위험지각이 보험 구매의도에 미치는 영향 - 제주도를 중심으로 -)

  • Lee, Ho-Seung;Kang, Seung-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.11
    • /
    • pp.490-502
    • /
    • 2021
  • Horticultural facility farmers subscribe to crop accident insurance and insurance products secured by horticultural facilities in preparation for possible risks in the facility. Insurance is purchased to prepare for natural disasters such as typhoons, hail, frostbite, heavy rain, and strong wind damage covered by the product. In order to find out the effect of risk perception, which is a subjective perception of the risks of a given situation, on horticultural facility farmers' intention to purchase horticultural facility insurance products, the risk perception and insurance purchase intention were analyzed. A t-test was conducted to determine the impact relationship between farm size, insurance coverage, and risk perception, and multiple regression analysis was conducted to verify the effect of personal characteristics and behavioral factors such as subjective perception, reference group, media exposure, and compensation understanding. In addition, a three-step regression analysis by Baron & Kenny was conducted to confirm the mediating role of personal characteristics and behavioral factors in the relationship between risk perception and insurance purchase intention. As a result of the study, although there was no difference in farm size, it was analyzed that policy holders had a higher degree of risk perception than non-subscribers, and that compensation understanding had the greatest influence and subjective knowledge had the smallest influence. In addition, these four factors were verified to have a mediating effect on the relationship between risk perception and insurance purchase intention. These results are expected to provide practical help to the development and marketing activities of horticultural facility insurance products.

Analysis of the Factors Influencing PM10 & PM2.5 in Korea by Panel Quantile-Regression (패널 분위회귀분석을 통한 한국의 미세먼지 국내외 영향요인 분석)

  • Kim, Haedong;Kim, Jaehyeok;Jo, Hahyun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.85-112
    • /
    • 2022
  • This study analyzed the influence of domestic and Chinese factors on fine dust(PM10 & PM2.5) in Korea by using the panel quantile regression. Daily analysis was conducted for 11 regions in Korea. For domestic factors, electricity demand and traffic volume, and for Chinese factors, interaction term of Chinese three cities' fine dust and the domestic west wind are used. As a result, the influence of domestic factors was different when the domestic fine dust concentration was high and low. When the fine dust concentration was low, electricity demand had a positive effect only on PM2.5, and didn't affect PM10 in the national analysis. In regional analysis, the amount of electricity demand had a significant effect on fine dust and ultrafine dust only in the capital area and Chungcheong. Electricity demand was found to significantly increase both PM2.5 and PM10 when it was high. On the other hand, it was confirmed that the Chinese factor always had a significant effect regardless of the concentration of PM10 and PM2.5. Therefore, in order to solve the problem of high concentration of fine dust, in addition to international cooperation, the reduction of PM2.5 generated by domestic thermal power generation should also be strengthened compared to the present.

Utilization of Evergreen Ground Covers in Central Region of Korea as Landscape Materials -Focusing on the Changes in Leaf Color Related with Light during Winter- (중부지방 상록지피식물의 조경적 이용 -광이 월동중의 엽색에 미치는 영향을 중심으로-)

  • Nam, Yu-Kyeong;Kim, Myung-Hyoe
    • Journal of agriculture & life science
    • /
    • v.45 no.2
    • /
    • pp.1-7
    • /
    • 2011
  • Three evergreen ground-cover species were tested and evaluated for cold acclimation with different lights in central Korea to enrich the varieties of ground cover plants for over-wintering. Nandina domestica which recently started to be planted in central Korea had high chlorophyll unit with shade condition in both locations, Banpo and Gwacheon during winter. Light condition had no influence on chlorophyll unit in Banpo after April, meanwhile full sun condition decreased chlorophyll unit significantly in Gwacheon, which is exposed to cold wind from north. Ophiopogon japonicas had more than double chlorophyll unit in shade condition compared to that in full light condition in both investigation areas in February. In addition, higher value of L and b in shade condition had been maintained than in full sun condition throughout investigation period. However, leaves in Gwacheon were de-colorized in full sun condition after over-wintering. Pachysandra terminalis had more higher chlorophyll unit in shade condition compared to in full sun condition in both investigation areas in February. But light conditions had not effect the difference of chlorophyll unit of Gwacheon in April. Therefore, The present results suggest that evergreen ground covers with shade condition would be used as landscape materials in the capital area.