• Title/Summary/Keyword: the building energy efficiency rating

Search Result 65, Processing Time 0.019 seconds

An Analysis on Characteristics and the Development of Estimation Model of Internal Heat Gain from Appliances in Apartment Units (공동주택 단위세대의 기기발열 특성 분석 및 추정모델 개발)

  • Lee, Soo-Jin;Jin, Hye-Sun;Kim, Sung-Im;Lim, Han-Young;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.19-26
    • /
    • 2018
  • The purpose of this study was to analyze characteristics and to develop estimation model of IHG(Internal Heat Gain) from appliance in domestic apartment units. To do this, it was defined the source of IHG from appliance and the calculation method through the case study of international and domestic codes. And the equipment related datum such possession, usage or not, etc were collected through field survey in apartment units, and the appliances' electricity consumption were measured separately from overall electricity consumption. Annual electricity consumption value were calculated with field survey datum and appliances' electricity consumption measurement datum, and then IHG value was calculated by applying PHPP v9 method. And it was conducted correlation analysis between IHG value and the area for exclusive use, the number of occupants, and then the IHG from applianace estimation model was deducted with regression analysis. Finally, it was analyzed the present level and of the domestic code(The Building Energy Efficiency Rating System) comparing with the value of estimation model, and the various international codes(HERS, Building America, SAP).

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

A Study on the Development of Sustainable Durability Design System for Reinforced Concrete Structure under Chloride Attack Environments (염해 환경하의 철근콘크리트 구조물의 친환경 내구설계 시스템 개발에 관한 연구)

  • Kim, Rak-Hyun;Roh, Seung-Jun;Tae, Sung-Ho
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.87-94
    • /
    • 2011
  • This study was suggested to develop sustainable durability design system and proposed the plan to evaluate design conditions that meet the intended service life and $LCCO_{2}$ reduction level of reinforced concrete structure easily from the early design stage. For that the W/B and covering depth of the concrete structure were calculated through calculation of service life based on standard specification expression and the quantitative reduction rate of the vertical member of reinforced concrete structure by the calculated W/B was applied. Life cycle of building classified into construction stage, operation stage, maintenance stage, and demolition/disposal stage and the method of $CO_{2}$ evaluation of each stage was proposed. For construction stage, the major construction materials that take up over 80% $CO_{2}$ emitting during building construction were selected and the $CO_{2}$ evaluation method for 5 standard apartment houses was proposed. Also, for operation stage, $CO_{2}$ emission was calculated through calculation of heating load by energy efficiency rating certification system. For maintenance stage, $CO_{2}$ emission was calculated using concept of re-construction by life and for demolition/disposal stage was calculated with the use of construction standard estimate. As a result of the case study by such evaluation methods, 80 years of service life and 17 specifications of sustainable durability design that meet the 40% intended $LCCO_{2}$ reduction level were deduced. The Maximum $LCCO_{2}$ reduction rate was analyzed by 47.2%.

Policy Directions to Build on Nature-Friendly Park Facilities - Based on an Evaluation on the Nature-Friendliness of Park Facilities in National Parks - (자연친화적인 공원시설 설치를 위한 정책방향 - 국립공원 공원시설의 자연친화성 평가를 근거로 -)

  • Park, Chang-Sug;Bae, Min-Ki;Kim, Tae-Jin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.1-12
    • /
    • 2009
  • The purpose of this research was to propose policy directions for the design and construction of nature-friendly park facilities (PF) in national parks. In order to do that, nature-friendliness evaluation indicators(NEIs) used in green building rating systems and related articles were reviewed. After the initial literature review was complete, NEIs for park facilities based on location, design, construction, operation, and management sectors were developed. Data was obtained through a questionnaire completed by 79 managers at 19 national parks in Korea in 2008. The answers were analyzed using descriptive statistical methods, a t-test, a multi-dimensional analysis, and a factor analysis. This research found that: 1) The results indicated that based on relative weight calculation, the location condition was evaluated as the most important; 2) The evaluation results regarding the degree of nature-friendliness of park facilities showed that location condition was ranked higher than design and construction--in addition, the evaluated values of indicators related to energy efficiency were ranked the lowest; 3) the level of nature-friendliness of shelter was given the highest level, but resting facility was the lowest level; 4) Overall, park facilities at Mt. Seorak, Mt. Odae, and Taean Coast national parks showed high levels of nature-friendliness. But park facilities at Mt. Gyeongju and Mt. Songni national parks showed low levels of nature-friendliness. The results of this research shall contribute to the establishment of tailor-made management policies, the development of detailed guidelines for increased energy efficiency and visitor satisfaction, and the preservation of ecosystems and natural resources in Korea's national parks.