• Title/Summary/Keyword: the blocked rotor test

Search Result 7, Processing Time 0.026 seconds

A Study on the Parameters and Characteristics of Induction Motor Driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.34-42
    • /
    • 2000
  • In this paper conventional technique will be described, which can be used for the measuring various parameters of induction motor. This is followed by presenting some other, alternative, techniques. The two tests are described which are suitable to obtain the electrical parameters of symmetrical 1hp three-phase squirrel-cage induction motor. These are the blocked rotor test and no load test. By the application of these, it is possible to determine the parameters which are presented in the steady-state equivalent-circuit of determining an induction motor. One conventional method of determining the inertia of an induction motors is obtained by performing retardation tests. The angular rotor speed of the motor is monitored, following its disconnection from the stator supply. Since the inertia torque J dw/dt contains the inertia coefficient J and the friction and windage torque Bw contains the coefficient B, then J and B can be determined by performing retardation tests.

  • PDF

Determination of Induction Motor equivalent circuit parameters by Inverter Source (인버터 전원에 의한 유도전동기 등가회로 결정)

  • Jeong, Young-Jun;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.160-162
    • /
    • 2001
  • A determining method of the $\Gamma$ type eqivalent circuit parameters of induction motor driven by inverter source is proposed in this paper. The no-load test by rated frequency (60 Hz) and a blocked rotor test by 25% of rated frequency (l5Hz) are performed with inverter source, and the DC resistance of the stator winding is measured. To determine the more accurate parameters, four simultaneous equations obtained from equivalent circuit of the no-load test and blocked rotor test are solved by using initial values which are evaluated from simplified equivalent circuits. The induction motor performances are computed by using these parameters and compared with measured values of the tested motor. Then it is found that the compared results show good agreement between them.

  • PDF

A Study on the Parameters and Characteristics of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • Jeon, Nae-Suck;Kim, Jong-Yun;Park, Chan-Kun;Eum, Sang-O;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1111-1113
    • /
    • 2000
  • This paper presents the calculation method for the equivalent-circuit parameters and torque characteristics of squirrel-cage induction motors. The measurement of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test to T type equivalent-circuit. Especially, this paper describes the test results obtained by using hall sensor and strain gauge for the current and torque characteristics of induction motors. Three-phase squirrel-cage induction motor which has 1[hp] was used to the test and the parameters obtained by the test were compared with the maker parameters.

  • PDF

A Study on the Parameters and Characteristic of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.497-504
    • /
    • 2000
  • This paper presents a method for the equivalent-circuit parameters and torque characteristics calculation of squirrel-cage induction motors. The measurment of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test through T type equivalent-circuit method. Especially, this paper describes the test results obtained by using hall sensor and strain gage for the current and the torque characteristics of induction motors. 1(HP), three-phase squirrel cage induction motor has been used during the test and the parameters are compared with those obtained by the maker parameters of simulation results and experiment.

  • PDF

A Study on the Starting Characteristics Prediction of Induction Motors (유도전동기의 기동특성 예측에 관한 연구)

  • 전내석;박정환;조성훈;이성근;김윤식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.7
    • /
    • pp.1308-1313
    • /
    • 2001
  • This paper presents methods of parameter measurement and starting characteristics of a 3 phase induction motor. The motor parameters measured by DC test, blocked rotor test, and no load test are used as the input data for computer simulation. Starting characteristics are analyzed through computer simulation using measured parameters, and the simulation results are compared with the experimental results obtained by using strain gauge attached on the motor shaft. It is conformed that the experimental results are very similar to those of the simulation.

  • PDF

A Study on the Starting Characteristics Prediction of Induction Motors (유도전동기의 기동특성 예측에 관한 연구)

  • Jeon, Nae-Suck;Jang, Su-Hyoung;Park, Jung-Hwan;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.849-851
    • /
    • 2001
  • This paper presents experimental method of parameter measurement and starting characteristics of 3 phase induction motor. Equivalent circuit parameters measured by DC test, the blocked rotor test, and no load test were used as the input data for computer simulation. Starting characteristics, such as starting current and torque were analyzed through computer simulation by Matlab, and the simulation results were compared with experiment using strain gauge attached on motor shaft. We conform that experimental results are very similar to that of simulation.

  • PDF

Comparison of Loss Characteristics of High-Efficiency Induction Motor by Parameter Measurement Test (정수 측정 시험에 의한 고효율 유도 전동기의 손실 특성 비교)

  • Pyon, H.S.;Kim, S.C.;Yang, S.H.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.318-320
    • /
    • 1999
  • Electric motor transforms electric power into mechanical power. It is important to increase efficiency of motor to save energy and to decrease operating cost. In this paper, some parameters and losses of high-efficiency induction motor and standard induction motor are measured by blocked-rotor test and no-load test. Operational parameters of high-efficiency induction motor that are compared with those of standard motor.

  • PDF