• Title/Summary/Keyword: the area of a circle

Search Result 261, Processing Time 0.034 seconds

Comparison and Analysis of Information Exchange Distributed Algorithm Performance Based on a Circular-Based Ship Collision Avoidance Model (원형 기반 선박 충돌 피항 모델에 기반한 정보 교환 분산알고리즘 성능 비교 분석)

  • Donggyun Kim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.6
    • /
    • pp.401-409
    • /
    • 2023
  • This study compared and analyzed the performance of a distributed area search algorithm and a distributed probability search algorithm based on information exchange between ships. The distributed algorithm is a method that can search for an optimal avoidance route based on information exchange between ships. In the distributed area search algorithm, only a ship with the maximum cost reduction among neighboring ships has priority, so the next expected location can be changed. The distributed stochastic search algorithm allows a non-optimal value to be searched with a certain probability so that a new value can be searched. A circular-based ship collision avoidance model was used for the ship-to-ship collision avoidance experiment. The experimental method simulated the distributed area search algorithm and the distributed stochastic search algorithm while increasing the number of ships from 2 to 50 that were the same distance from the center of the circle. The calculation time required for each algorithm, sailing distance, and number of message exchanges were compared and analyzed. As a result of the experiment, the DSSA(Distributed Stochastic Search Algorithm) recorded a 25%calculation time, 88% navigation distance, and 84% of number of message exchange rate compared to DLSA.

Hado and Russell's Paradox (하도(河圖)와 러셀 역설)

  • Kim, Byoung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.3
    • /
    • pp.583-590
    • /
    • 2007
  • The significance of Han medicine (韓醫學), the Korean traditional medicine, that has lasted throughout the past couple millenniums relies upon Han Philosophy distinguished by its uniqueness. In brief, the specificity of Han medicine is characterized by unity of spirit and body, part and whole. According to this theory, when curing a frozen shoulder, it is usually cured by acupuncturing the area around the part that aches, but also doing so on the area that is totally different from the aching part such as the opposite part of the body. In fact, this can be pursued only through aspects that enable one to realize the unity of part and whole, and a ground for this possibility bases upon the crux of Eastern Philosophy, I-ching(역), such as theory of Five Elements (음양오행) and Three Pillars(삼재). In Western set theory, the issues of Class(부류) and elements(요원), whole and part were independently discussed in the area of mereology, and the question of part and whole was encountered with aporia and paradox since Greek ancient philosophy. At the turn of this century, many philosophers endeavored to pursue academic inquiry to resolve this paradox, especially by Russell and Whitehead through ${\ll}$Principia Mathematica${\gg}$ at the beginning of this century. in the process, there came out a phrase 'Russell's Paradox'. Russell himself proposed a typological resolution as an answer to the inquiry. However, 'Russell's Paradox' still remains as an aporia even till present days. During medieval period, this inquiry was even considered as 'insolubia'. Throughout this paper, 1 attempt to provide an analytic aspect on 'Russell's Paradox' from an unique thinking method and perspective of Han medicine that embodies the concept of 'unity of part and whole'. To do so, 1 suggest a physiological model in the first place depicted by diagrams of Circle 원, Quadrangle 방, Triangle 각(CQT) that portray the logic of Hado or Hotu 하도 which is 'the pattern from the river Ho'. That is to suggest that CQT원방각 of Hado can De a logical foundation that explains the notions of spirit (정신,뇌), internal organs(장부), and meridian system which functions as a solution to the question of 'Russell's Paradox'. There are precedent academic works examining the issue from philosophical aspect such as Sangil Kim's ${\ulcorner}$Han medicine과 러셀역설 해의${\lrcorner}$ Han Medicine and Resolution of Russell's Paradox(2005), and this analysis will further attempt to critically examine such works from a perspective of Han medicine.

Analysis of Heavy Metals in Annual Rings of Pinus thunbergii at Air Polluted Area (대기오염지역(大氣汚染地域)의 해송(海松) 연륜(年輪) 속의 중금속(重金屬) 분석(分析))

  • Kim, Jong-Kab;O, Ki-Chel
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.4
    • /
    • pp.429-437
    • /
    • 1999
  • Heavy metals(Cd, Cu, Pb and Zn) in tree rings of P. thunbergii growing at Onsan Industrial Complex of air polluted area were analyzed to study the condition of heavy metal pollution. The tree ring width began to decrease after operation of factories and decreased abruptly at Onsan Industrial Complex after 1991. Cd contents in tree rings showed 119.4ppb to 867.0ppb level and suddenly increased after 1991. Cu contents showed 309.5ppb to 3686.8ppb, and Pb contents 911.33ppb to 7997.1ppb and fluctuations of those were high after operation of factories. Zn contents showed the highest level of 3528.7ppb to 23826.7ppb and largely ascended after 1960, and increased suddenly after 1992, as compared to former tendency. On the other hand, heavy metal contents in tree rings of P. thunbergii at Gosung of non-air polluted area were far lower than Onsan I. C., and there was a wide difference between both areas after 1990. On the heavy metal contents accumulated in bark of P. thunbergii of both areas, it was higher to 10 times in Cd, 1,000 times in Cu, 285 times in Pb and 133 times in Zn contents at Onsan than at Gosung. In the heavy metal analysis for circle plate and cores, heavy metal contents in cores were generally higher than those in disk and Pb contents showed specially high difference, but pattern of variation by tree age showed a similar tendency.

  • PDF

A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE (주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구)

  • Dong, Jin-Keun;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

Design and Evaluation of a Scalding Animal Model by the Boiling Water Method

  • Hua, Cheng;Lyu, Lele;Ryu, Hyun Seok;Park, So Young;Lim, Nam Kyu;Abueva, Celine;Chung, Phil-Sang
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.51-57
    • /
    • 2020
  • Background and Objectives For experiments on simulated burn, the preparation of an animal model is a very important step. The purpose of the current experiment is to design a simple and controllable method for the preparation of third-degree scald in a mouse model using the boiling water method. Materials and Methods A total of 18 Swiss mice were used. After the anesthetization, the mice were scalded by boiling water (100℃) using a mold with a 1 cm2 circle area on the dorsum at contact times of 3s, 5s, and 8s. After confirming that 8 seconds of scald can cause a third-degree scald, the skin samples were collected at day 2, 4, 6, 8, 10, and 12, and analyzed by histopathological examinations. The wound retraction index (WRI) was also measured. Results Third-degree scald involving full-thickness skin was observed in the 8-second scald group, while a 3-second scald caused a superficial second-degree scald and a 5-second scald caused a deep second-degree scald. After third-degree scald, the burn wound continued to contract until day 14. Conclusion The scalding model of mice can be successfully established by the boiling water method. This method is easy to operate, it has a low cost, and it can control the scald depth by controlling the scald time. This is adequate to study skin thermal injury in the future. The scald model established by this method can last for 14 days.

An experimental study on the size selectivity of fusiform fish by the netting characteristics (망지 특성에 따른 방추형 어류의 크기 선택성에 대한 실험적 연구)

  • Sena BAEK;Hyungseok KIM;Kyung-Jin RYU;Seonghun KIM
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.3
    • /
    • pp.189-195
    • /
    • 2023
  • This study quantitatively evaluated size selectivity for three netting shapes (T0; regular, T45, T90) and hanging ratio (35%, 70%) of T0 netting used for trawl codend. The size selectivity experiment was performed in a tank using a cube experimental model with a length of 50 cm on one side and 389 experimental individuals, jack mackerel (Trachurus japonicus). In the selectivity analysis, a selectivity curve was created based on the selection ratio using a logistic function, and the 25%, 50%, and 70% selection length and selection range (SR) were obtained. The T0 netting was 19.54 cm when the 50% selective length, which is a selectivity evaluation index, had a hanging ratio of 35%, a selection range of 0.51 cm, and 22.70 cm and 3.08 cm for the hanging ratio of 70%. The T45 netting was 24.34 cm and 2.13 cm, and the T90 netting was 23.51 cm and 2.84 cm. The results of the T45 netting and the T90 netting are similar, and the 50% selection length and selection range were relatively larger than the T0 netting. There was a significant difference in the correlation between the circumference of the inner circle of the mesh by the shape of the netting and the body girth of the experimental individual (Pearson test, r = 0.86, p < 0.05). There was no significant difference in the correlation between the selection ratio by the T0 netting, T45 netting, and T90 netting with a 70% hanging ratio (one-way ANOVA, p > 0.05). The results of this study showed that selectivity such as T45 netting and T90 netting appeared when the hanging ratio, which maximizes the area of T0 netting, was maintained at 70%.

Striving Towards a Holistic Innovation Policy in European Countries - But Linearity Still Prevails!

  • Edquist, Charles
    • STI Policy Review
    • /
    • v.5 no.2
    • /
    • pp.1-19
    • /
    • 2014
  • The concept of a holistic innovation policy is defined in this article, with discussions of what it is, why it is relevant, and how it can be implemented to enhance product innovation. It is shown that the innovation systems approach has diffused rapidly during the latest decades and has completely replaced the linear view in the field of innovation research. The majority of European countries are striving in the direction of developing a more holistic innovation policy. However, it is concluded that the innovation policies in European countries are still dominantly linear despite the fact that holistic policy seems to be the driving vision. Innovation policy is behindhand. Why innovation policy is still linear is also preliminarily discussed. Policymakers attending conferences on innovation are practically always in favor of holistic (systemic, broad-based, comprehensive, etc) innovation policies, have abandoned the linear view by learning from innovation research. The division between "linear" and "holistic" seems to be located within the community where innovation policies are designed and implemented, a community composed of policymakers (administrators/bureaucrats) and elected politicians. Perhaps the dividing line is between these two groups in that politicians, who actually make the decisions, may still reflexively believe in the linear view. Nevertheless, there seems to be a failure in communication between researchers and politicians in the field of innovation and there is therefore a strong need to involve innovation researchers in policy design and implementation to a much higher degree. Another way to increase the degree of holism could be to separate innovation policy from research policy, since their integration tends to cement the linear character of innovation policy. The empirical results are based on a questionnaire sent to twenty-three EU Member States, out of which nineteen (83%) responded. Part of the work for this article was carried out for the European Research and Innovation Area Committee (ERAC) of the European Commission (DG RTD).

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

The estimation of river discharge by using the mean velocity equation in a unsteady condition (평균유속공식을 이용한 부정류 하천유량 산정)

  • Choo, Tai Ho;Chae, Soo Kwon;Yoon, Hyeon Cheol;Yun, Gwan Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6558-6564
    • /
    • 2013
  • As the average indicator for amount of water flowing in any cross section of a river, the mean discharge has been reported to be a very important factor for examining water circle constructions in a river basin, the design and construction of a hydraulic structure, and water front area use and management. The stage-discharge curve based on discharge and stage data measured in a normal season were basically derived. Using this derivation, the necessary discharge data was obtained. The values produced in this manner corresponded to the measured data in a uniform flow state well, but showed limited accuracy in a flood season (unsteady flow). In the present paper, the mean velocity in unsteady flow conditions, which exhibited loop form properties, was estimated using the new mean velocity formula derived from Chiu's 2-D velocity. The results of RMSE and Polar graph analyses showed that the proposed equation exhibited approximately nineteen times the accuracy compared to the Manning and Chezy equations.