• Title/Summary/Keyword: the amount used

Search Result 13,149, Processing Time 0.042 seconds

Analysis of Cell Performance with Varied Electrolyte Species and Amounts in a Molten Carbonate Fuel Cell

  • Lee, Ki-Jeong;Kim, Yu-Jeong;Koomson, Samuel;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.141-148
    • /
    • 2018
  • This study evaluated the performance characteristics of varied electrolyte species and amounts in a molten carbonate fuel cell (MCFC). Coin-type MCFCs were used at the condition of $650^{\circ}C$ and 1 atm. In order to measure the effects of varied electrolyte species and amounts, electrolytes of $(Li+K)_2CO_3$ and $(Li+Na)_2CO_3$ were selected and the amounts of 1.5 g, 2.0 g, 3.0 g, and 4.0 g were used. Insignificant performance differences were observed in the cell using different electrolytes, but the cell performance was sensitive to the amount of the electrolyte used. The pore-filling ratio (PFR), a ratio of pore filling in the components by the liquid carbonate electrolytes, was used to determine the optimum performance range. Consequently, 77% PFR demonstrated the optimum performance for both electrolytes. Thus, the MCFC had a permissible but narrow optimum performance range. The remaining amounts of electrolyte in the cells were determined using the weight reduction ratio (WRR) method after several hours of cell operation. The WRR used the relationship between the initial loaded amount of electrolyte and weight reduction of components in 10 wt% acetic acid. The relationships were linear and identical between the two electrolyte species.

Fabrication of Niobium Powder for Solid-electrolyte Capacitors (고체 전해커패시터용 니오븀 분말제조)

  • Yoon, Jae-Sik;Hwang, Sun-Ho;Kim, Byung-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.227-231
    • /
    • 2009
  • The niobium capacitor showed somewhat more unstable characteristics than the commercial tantalum capacitors, but is nonetheless considered applicable as a future substitute for tantalum capacitors. In this study, niobium powder was fabricated by metallothermic reduction process using $K_2NbF_7$ as the raw materials, KCl and KF as the diluents and Na as the reducing agent. The niobium particle size greatly decreased from 0.7um to 0.2 um as the amount of diluent increased. However if a higher surface area of powder is required, more diluents need to be used in the said method in order to produce niobium powder. The niobium powder morphology and particle size are very sensitive to a amount of sodium excess. The particle size of niobium powder increased with a increasing amount of sodium excess. When more diluent and sodium are used, the niobium powder will be contaminated with more impurities such as Fe, Cr, Ni so on.

The Study on Methane Gas Generation Rate from Chon-An Beck-Suk Landfill Site (천안백석매립장을 중심으로 한 메탄가스 발생량에 관한 연구)

  • Jeong, Jin Do;Kim, Jang U;Jeong, In Gwon;Bae, Chan Yeol
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.697-701
    • /
    • 2004
  • Most of methane gas result from waste matter in landfill, therefore the persons concerned take an increasing interest in management of gases in landfill. Infrared Gas Analyzer was used to measure components of gases, $CH_4,$ $CO_2,$ $O_2,$ through gas exhausted pipe. To measure amount of the gas flow meter(Portable Hot-Line Current Meter) was used and it was set at right angles with direction of the flow. In this research the total amount of methane gas produced in Beck-Suk Landfill was calculated through FOD method suggested by IPCC. This research found that in Chon-An Beck-Suk Landfill anaerobic resolution was made actively and the amount of methane gas produced there was 54.14%, which is higher than common figure, 50%, in other researches. The components of reclaimed waste matter, especially, organic waste matter can have a great effect of the amount of the greenhouse gases produced in landfill. We can expect that the amount of greenhouse gas will decrease from 2005, when it will be prohibited from carrying kitchen refuse and sludge into landfill.

Development of models for evaluating the short-circuiting arc phenomena of gas metal arc welding (GMA 용접의 단락이행 아크 현상의 평가를 위한 모델 개발)

  • 김용재;이세헌;강문진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.454-457
    • /
    • 1997
  • The purpose of this study is to develop an optimal model, using existing models, that is able to estimate the amount of spatter utilizing artificial neural network in the short circuit transfer mode of gas metal arc (GMA) welding. The amount of spatter generated during welding can become a barometer which represents the process stability of metal transfer in GMA welding, and it depends on some factors which constitute a periodic waveforms of welding current and arc voltage in short circuit GMA welding. So, the 12 factors, which could express the characteristics for the waveforms, and the amount of spatter are used as input and output variables of the neural network, respectively. Two neural network models to estimate the amount of spatter are proposed: A neural network model, where arc extinction is not considered, and a combined neural network model where it is considered. In order to reduce the calculation time it take to produce an output, the input vector and hidden layers for each model are optimized using the correlation coefficients between each factor and the amount of spattcr. The est~mation performance of each optimized model to the amount of spatter IS assessed and compared to the est~mation performance of the model proposed by Kang. Also, through the evaluation for the estimation performance of each optimized model, it is shown that the combined neural network model can almost perfectly predict the amount of spatter.

  • PDF

Strength evaluation of concrete with fly ash and GGBFS as cement replacing materials

  • Chore, H.S.;Joshi, M.P.
    • Advances in concrete construction
    • /
    • v.3 no.3
    • /
    • pp.223-236
    • /
    • 2015
  • Concrete is the most widely used material of construction. Concrete gained the popularity as a construction material due to the easy availability of its component materials, the easy formability, strength and rigidity upon setting and curing.In construction industry, strength is the primary criterion in selecting a concrete for a particular application. Now a days, the substantial amount of waste materials, containing the properties of the Pozzolana, is being generated from the major industries; and disposal of such industrial wastes generated in abundance is also a serious problem from the environmental and pollution point of view. On this backdrop, efforts are made by the researchers for exploring the possible utilization of such waste materials in making the sustainable construction material. The present paper reports the experimental investigations to study the strength characterization of concrete made from the pozzolanic waste materials. For this purpose, the Pozzolanic materials such as fly ash and ground granulated blast furnace slag were used as a cement replacing materials in conjunction with ordinary Portland cement. Equal amount of these materials were used in eight trial mixes with varying amount of cement. The water cement ratio was also varied. The chemical admixture was also added to improve the workability of concrete. The compressive strengths for 7, 28, 40 and 90 days' were evaluated whereas the flexural and tensile strengths corresponding to 7, 28 and 40 days were evaluated. The study corroborates that the pozzolanic materials used in the present investigation along with the cement can render the sustainable concrete.

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.

Analysis of Time Use of Mother and Father in Single-Parent Family (한부모가족 부 .모의 생활시간 분석)

  • 조영희
    • Journal of Families and Better Life
    • /
    • v.22 no.1
    • /
    • pp.139-151
    • /
    • 2004
  • The purposes of this study were to examine the time use on weekdays and weekends by the time amount of each activities and compare time amounts of single parent with that of two parents family. So two methods were applied, one was secondary data analysis ,the other was deep-interview. The major findings of analysis of time use were as follows; 1) Mothers in single parent family used significantly less time amount of household labor and family care than them in two parent family 2) Fathers in single parent family used significantly more time amount of household labor but used significantly less time amounts of family care than them in two parent family And 3) Mothers in single parent family used significantly more time amounts of household labor and family care than fathers in single parent family. The results of deep-interview were as follows; roughly the amounts of household labor time, family care time, leisure time were of little quantity and absence of spouse, family size, family life cycle stage, economic condition, sex role identity, psychological factor maybe seemed important.

Fabrication of K-PHI Zeolite Coated Alumina Hollow Fiber Membrane and Study on Removal Characteristics of Metal Ions in Lignin Wastewater

  • Zhuang, XueLong;Shin, Min Chang;Jeong, Byeong Jun;Lee, Seung Hwan;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.174-179
    • /
    • 2021
  • Recently, hybrid coal research is underway to upgrade low-grade coal. The hybrid coal is made by mixing low-grade coal with bioliquids such as molasses, sugar cane, and lignin. In the case of lignin used here, a large amount of lignin is included in the wastewater of the papermaking process, and thus, research on hybrid coal production using the same is attracting attention. However, since a large amount of metal ions are contained in the lignin wastewater from the papermaking process, substances that corrode the generator are generated during combustion, and the amount of fly ash is increased. To solve this problem, it is essential to remove metal ions in the lignin wastewater. In this study, metal ions were removed by ion exchange with a alumina hollow fiber membrane coated with K-Phillipsite (K-PHI) zeolite. The alumina hollow fiber membrane used as the support was prepared by the nonsolvent induced phase separation (NIPS) method, and K-PHI seeds were prepared by hydrothermal synthesis. The prepared K-PHI seed was seeded on the surface of the support and coated by secondary growth hydrothermal synthesis. The characteristic of prepared coating membrane was analyzed by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Energy Dispersive Spectroscopy (EDX), and the concentration of metal ions before and after ion exchange was measured by Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES). The extraction amount of K+ is 86 mg/kg, and the extraction amount of Na+ is 54.9 mg/kg. Therefore, K-PHI zeolite membrane has the potential to remove potassium and sodium ions from the solution and can be used in acidic lignin wastewater.

Adsorption of Heavy Metal Ions on Bark(I) (수피에 의한 중금속 흡착(I))

  • Paik, Ki-Hyon;Kim, Dong-Ho;Yoon, Seung-Lak
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.3
    • /
    • pp.391-398
    • /
    • 1996
  • The pretreatment of bark powder with sodium hydroxide and formalin showed the most excellent adsorption ratio, but this method could not practically be used because of the occurrence of dark-colored pigments in filtrates during pretreatment. Instead, acid and formalin were the most affirmative and effective among the pretreatment methods tested, and could be used for this purpose. Among tested species, Quercus acutissima and Robinia pseudo-accacia showed the largest amount of metal adsorption, and $Pb^{2+}$ was the best(83 to 96%) among the four heavy metals tested. The order of adsorption ratios other metals was as follows; $Cu^{2+}$ > $Zn^{2+}$ > $Cd^{2+}$, and the ratio was approximately 45 to 55%. In addition, as the substrate amount increased, the amount of adsorbed heavy metals in subtrates gradually increased, but the adsorbed amount was not proportional to the substrate amount. The order of heavy metal adsorption was as follows; $Pb^{2+}$ > $Cu^{2+}$ > $Cd^{2+}$ > $Zn^{2+}$. Depending on flow rate and column size, pine bark power adsorbed more heavy metals in the 5ml/min flow rate and 3.5cm column size rather than the 10ml/min and 2.0cm. However, oak bark power showed contrary results compared with pine bark powder. The adsorption of $Pb^{2+}$ occurred rapidly in the incipient stagte. Even though bark powders were repeatedly used three times, there was no change in the adsorption ratio(45%), but after four times, the adsorption ratio was significantly reduced to 35%.

  • PDF

Qunntitation of Fentanyl Remaining in Used Patches (Fentanyl Patch의 사용후 잔량분석)

  • Bae, Yang Soo;Ahn, Jung Soon;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.6 no.2
    • /
    • pp.24-27
    • /
    • 1996
  • In order to determine whether there was a clinically sufficient amount of drug remaining in used fentanyl patches, quantitative analysis of two different types of patches, each containing 2.5 mg (n=36) and 5 mg (n=20) was performed. After being used for approximately 72 hours by patients with cancer, each patch was put in the plastic bag and stored at $4^{\circ}C$ until analysis. Fentanyl remaining in patches was extracted with 50 ml methanol, diluted with water, and counted twice in a $\gamma-Counter$ (expressed as CPM). Patches that originally contained 2.5 mg and 5 mg of fentanyl were shown to have $0.48{\sim}1.86\;mg\;(mean:\;1.03\;mg,\;41.16\%)\;and\;0.37{\sim}3.95\;mg\;(mean:\;2.37\;mg,\;47.33\%)$ after use, respectively. A wide interpatient variability was observed in the rate of fentanyl release from patches although the application period was standardized to 72 hours. Since a significant amount of drug remained in the discarded patches, it is highly recommended that patients dispose used ones under supervision to prevent abuse or misuse of the narcotic drug.

  • PDF