• Title/Summary/Keyword: the Korean Ophthalmic Optics Society

Search Result 1,184, Processing Time 0.037 seconds

A study on the global optimization in the design of a camera lens-system (사진 렌즈계 설계에서 전역 최적화에 관한 연구)

  • Jung, Jung-Bok;Jang, Jun-Kyu;Choi, Woon-Sang;Jung, Su-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.121-127
    • /
    • 2001
  • While SVD and Gaussian elimination method were applied to the additive damped least squares(DLS), the convergence and the stability of the optimization process were examined in a triplet-type camera lens-system where the condition number is well conditioned. DLS with SVD method generated a suitable merit function but this merit function may be trapped in a local minimum by the nonlinearity of error function. Therefore, the least camera lens-system was further designed by the global optimization method is grid method, and this method is adopted to get merit function that convergent to global minimum without local minimum trapping.

  • PDF

The Analysis of a Educational Objectives and a Curriculum of The Department of Ophthalmic Optics Departments of Two-Year Colleges (2년제 대학 안경광학과 교육목표와 교육과정 분석)

  • Ryu, Kyung Ho;Kim, Jung Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.65-70
    • /
    • 2007
  • This research aims at knowing educational objectives and understanding the whole departmental processes of two-year education programs of junior colleges in the field of ophthalmic optics. Our analyses can be categorized by on liberal art courses, compulsory subjects and optional subjects. The educational purpose of all the seven colleges was training the professional worker, meets well the educational requirements of two year college. All seven colleges' curriculum is open to the national licence examination subjects, but more academic credits are demended in eye examination of refraction, test of ocular function, professional sense of cultural subjects field, leadership in organization and course of marketing related subjects, and stronger relation with clinical examination are also required.

  • PDF

Vibration Analysis Using Laser Speckle (레이저 스펙클을 이용한 진동분석)

  • Ruck, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo;Lee, Won-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.77-80
    • /
    • 2001
  • The purpose of this work is that by using speckle phenomena of low-level He-Ne laser, it analyzes the movement condition of surface elements on a substance vibrating. The lights from laser reflect against a copper plate and will be shown as speckles on a vibration board. If we vibrate these speckles by sound waves of a speaker installed on the back, the speckles change with various shapes. When a vibration board has a maximum vibration, the frequency becomes a dynamical resonance frequency and we can mark the changes of speckles at that time on a vibration board.

  • PDF

Polymerization of Contact Lens Materials Using Silicone (Silicone을 이용한 콘택트렌즈 재료의 중합)

  • Kim, Tae-Hun;Ye, Ki-Hun;Kwon, Young-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2006
  • The purpose of this study is synthesizing silicone polymer which is used the material of contact lens and solving the problems of water content and light transmittance for gas permeable contact lens. We used NVP, MMA, HEMA monomer for polymerization and EGDMA as cross linking regent. Also, we polymerized with a several formulation arrangement for the best condition as contact lens. After that. we measured water content and light transmittance by each sample which was polymerized. We polymerized the silicone polymer which is simultaneously pursued by the transparent and water content of the material and measured their physical nature of each sample on this study.

  • PDF

Clinical Study on Accommodation Using Subjective Test (자각적 검사를 이용한 조절력에 관한 임상적 연구)

  • Jung, Mi-Boon;Lee, Ki-Seok;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.137-141
    • /
    • 2006
  • We have studied on the accommodation of people for 10~60ages at Honam residents and compared with the already known accommodation from age. Using Push-up method, we obtained results that average accommodation of each cases were 10ages 9.88D, 20ages 8.65D, 30ages 6.92D, 40ages 5.05D, 50ages 4.29D, 60ages 4.63D. Accommodation was on the decreased in increasing the ages but showed the very high accommodation in 50, 60ages on this study. We judged we should consider a accommodation research of other districts and near addition test.

  • PDF

Study on Clinical Assessment and Reliability Analysis of Measurement with Diverse Autorefractors (검사기기에 따른 굴절력 측정의 임상적 평가 및 신뢰도에 관한 연구)

  • Kim, Tae-Hun;Kwon, Young-Seok;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.293-298
    • /
    • 2006
  • For this study, Clinical evaluation of the diverse Autorefractors was performed to examine validity and repeatability compared with subjective refraction. Measurements of refractive error were performed on 212 eyes of 106 subjects subjectivly noncycloplegic. Intersession repeatability of the Autorefractors were also assessed on all 106 subjects together with intersession repeatability on 7 to 14 days intervals. Spherical powers of subjective refraction and autorefractions by Autorefractors were analyzed by paired T-test.

  • PDF

The Design of 2.2X Galilean Telescopic Spectacles (2.2X 갈릴레이식 망원안경의 설계)

  • Cha, Jung-Won;Lee, Dong-Hee;Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.247-253
    • /
    • 2005
  • We tried to design a Galilean telescopic spectacles for low vision which is with reference to goods of German. The design bases are that the magnification is 2.2X for general using and the diameter of aperture stop is 3mm. The Galilean telescopic spectacles is designed by using Sigma 2100 made in Kidger Optics Ltd. As a result, we have got the system that the MTF-value is more than 0.25 at 0.25 cycles/arc-minute and the distortion is under 1%. This system is judged to be useful for low vision.

  • PDF

The Importance of Optometric Education in Korea (한국에서 검안교육의 중요성)

  • Kim, Douk-Hoon;Sung, A-Young;Cullen, Anthony P.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.241-249
    • /
    • 2004
  • Since 1989 the number of nationally licensed ophthalmic and refracting opticians in Korea have increased. Currently, they are being educated in four universities, twenty six colleges and three graduate programs. It is innevitable that the growth of optometric education in Korea will be progressively influnced by worldwide influnces such as the World Council of Optometry(WCO), the World Health Organization (WHO), and the World Trade Organization(WTO). However, currently no standards for optometric education exist in Korea. Thus, the Korean Professional Councils of Ophthalmic Optics(KPCOO) must develope and provide standards for optometric education programs.

  • PDF

Analysis of Corneal Topography for Korean College Students Based on Computer-Assisted Videokeratography (각막지형도 검사를 이용한 대학생의 각막형태에 대한 연구)

  • Lee, Seok-Ju;Ryu, Guen-Chang;Shin, Cheol-Guen;Seong, Jeong-Sub;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.241-247
    • /
    • 2006
  • Purpose : To define the distribution of normal corneal topographic patterns of Korean college students and compare them with previously published western data, Bogan et al's study. Methods : Computerized corneal topography was performed 220eyes normal subjects using CTK-922(Topography, swiss made). Mean age of the subjects was 23.2 yr.(range 19 to 57 yr.). The color-coded videokeratographs were classified by a masked observer according to the Bogan et al's classification such as round, oval, symmetric bow tie, asymmetric bow tie, and irregular. Results: The results revealed 57 eyes(25.9%) had round, 14 (6.4%) oval , 41(18.6%)symmetric bow tie, 78(35.5%) asymmetric bow tie, and 30(13.6%) irregular pattern. Conclusions : Our results of topographic patterns show the tendency of more irregular and less round topographic pattern in Korean college students, as compared to that of western adults.

  • PDF