• Title/Summary/Keyword: the AIR model

Search Result 5,905, Processing Time 0.037 seconds

Thermal Behavior and Leaf Temperature in a High Pressure Sodium Lamp Supplemented Greenhouse (고압나트륨등 보광 온실의 열적 거동 및 엽온 분석)

  • Seungri Yoon;Jin Hyun Kim;Minju Shin;Dongpil Kim;Ji Wong Bang;Ho Jeong Jeong;Tae In Ahn
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.48-56
    • /
    • 2023
  • High-pressure sodium (HPS) lamps have been widely used as a useful supplemental light source to emit sufficient photosynthetically active radiation and provide a radiant heat, which contribute the heat requirement in greenhouses. The objective of this study to analyze the thermal characteristics of HPS lamp and thermal behavior in supplemented greenhouse, and evaluate the performance of a horizontal leaf temperature of sweet pepper plants using computational fluid dynamics (CFD) simulation. We simulated horizontal leaf temperature on upper canopy according to three growth stage scenarios, which represented 1.0, 1.6, and 2.2 plant height, respectively. We also measured vertical leaf and air temperature accompanied by heat generation of HPS lamps. There was large leaf to air temperature differential due to non-uniformity in temperature. In our numerical calculation, thermal energy of HPS lamps contributed of 50.1% the total heat requirement on Dec. 2022. The CFD model was validated by comparing measured and simulated data at the same operating condition. Mean absolute error and root mean square error were below 0.5, which means the CFD simulation values were highly accurate. Our result about vertical leaf and air temperature can be used in decision making for efficient thermal energy management and crop growth.

Development of Cabin Temperature Alteration Simulation Model for Position Optimization of Air Conditioner (Part I) (공조장치 위치 최적화를 위한 트랙터 캐빈 온도변화 시뮬레이션 모델 개발 (I))

  • Oh, Joo Seon;Chung, Woo Jin;Park, Seong Un;Park, Young Jun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.81-81
    • /
    • 2017
  • 본 연구는 전산유체역학(CFD)을 이용하여 트랙터 캐빈 내부의 온도 변화 시뮬레이션 모델을 개발하고 이를 통해 공조장치의 위치를 최적화 하는 것을 목적으로 하였다. 자동차나 열차를 대상으로 시뮬레이션을 이용한 차량 내부의 유동 해석 연구 사례는 많으나, 트랙터를 대상으로 한 연구 사례는 적다. 이에 트랙터의 공조장치를 설계하고 그 성능을 검증할 때 시뮬레이션 모델을 활용한다면, 인력, 시간 등의 손실을 줄일 수 있을 것이다. 본 연구에서는 상용 CFD 프로그램을 활용하여 공조 장치의 위치에 따른 세 가지 트랙터 캐빈 모델을 제작한 뒤, 각각의 모델에 대해서 열 유동 해석을 수행하였다. 시뮬레이션 결과가 실제 트랙터의 시험 결과와 비슷한 경향을 보이고 있음을 확인할 수 있었으며 이를 통해 모델의 적합성을 확인하였다. 또한 세 가지의 캐빈 모델 중 탑승자에게 가장 쾌적한 환경을 제공할 수 있는 모델은 기존의 국내 트랙터와 같은 천정부에 공조 장치가 있는 것이 아니라, 핸들이 있는 전면부에 위치하는 것이 가장 적합하다는 것을 확인할 수 있었다

  • PDF

Development of a land surface soil temperature prediction model considering air temperature and vegetation (기온과 식생을 고려한 지표면 토양온도 예측 모형 개발)

  • Cho, Seon-Ju;Kim, Sang-Dan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.284-288
    • /
    • 2012
  • 토양온도는 기후변화, 지역기상모형, 수생태 영향과 밀접한 상관성을 가지고 있으며 이에 대한 연구들이 활발하게 진행 중에 있다. 특히 기후는 토양의 분포와 성장, 그리고 소멸에 영향을 미치고, 식생은 증산과정에 의해 대기로 수분을 내보내는 과정을 통해 기후에 영향을 미치고 있다. 이 때, 지표면의 토양온도는 토양수분 및 식생의 성장에 영향을 미치게 된다. 이에 본 연구에서는 격자기반 일 지표면 토양온도 모형이 제안되며, 이를 이용하여 한반도 남동쪽에 위치한 낙동강 유역 내 안동댐 상류지역에 대한 지표면 토양온도가 모의된다. 제안된 모형의 구동을 위해 필요한 입력 자료는 일평균기온 및 관측 NDVI 자료이다. 전국 60개 지점에서 관측된 일 평균기온은 고도가 고려된 Krignig기법을 이용하여 격자별로 구축되며, NDVI 및 지표면 토양온도를 위한 위성자료는 적절한 전처리 과정을 거쳐 자료를 구축한다. 전반적으로 모의된 일 지표면 토양온도는 관측 자료를 잘 재현하고 있는 것으로 분석된다. 추가적으로 감쇠율을 적용하여 토양온도를 토양깊이에 따라 예측하는 방법이 제안되며, 토양깊이에 따라 토양온도가 감소하는 경향을 살펴볼 수 있을 것이다. 이상과 같이 본 연구에서 제안된 모형은 추후 하천수온예측 및 격자기반의 수문모형의 구성을 위한 기초자료를 제공할 것으로 기대된다. 더 나아가 본 연구는 기후-토양-식생의 관계를 바탕으로 미래기후에 대한 물 환경 영향을 평가하는데 있어서 기여할 수 있을 것으로 판단된다.

  • PDF

Application of AI-based model and Complex Network method for Comprehensive Air-Quality Index prediction (종합대기질 지수 예측을 위한 AI 기반 모형 및 Complex Network 기법 적용)

  • Kim, Dong Hyun;Song, Jae Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.324-324
    • /
    • 2022
  • 정확한 오염물질 예측은 기상학, 자연재해, 기후변화 연구 등 현장에서 필수적인 과제 중 하나이다. 주변 관측소에서 얻은 데이터를 사용하는 경우 모델 학습을 위한 불필요한 데이터로 인해 예측 결과에 왜곡 문제가 있을 수 있습니다. 따라서, 우리는 종합적인 대기질 지수 행동에 영향을 미치는 요인을 제공하는 최적의 데이터 소스를 찾기 위해 네트워크 방식을 사용했습니다. 본 연구에서는 2015년부터 2020년까지 우리나라의 6개 오염물질과 종합적인 대기질 지수 예측에 대한 네트워크 기법을 적용한 LSTM 및 DNN 모델을 적용하였다. 본 연구는 미세먼지(PM10), 초미세먼지(PM2.5), 오존(O3), 이산화황(SO2), 이산화질소(NO2), 일산화탄소(CO) 등 6가지 오염물질을 기반으로 종합적인 대기질 지수를 예측하는 2단계로 구성되어 있다. LSTM을 이용하여, 개별적으로 예측된 6가지 오염물질을 이용하여 DNN 모형을 이용하여 종합적인 대기질 지수를 예측한다. 6가지 오염물질에 대한 각 모델의 예측능력과 종합적인 대기질 지수 예측은 관측된 대기질 데이터와 비교하여 평가하였다. 본 연구는 심층신경망 모델과 네트워크 방식을 결합한 것이 높은 예측력을 제공함을 보여주었으며, 종합적인 대기질 지수 예측을 위한 최적의 모델로 선정되었다. 재난관리의 필요성이 증가함에 따라 네트워크 방식의 딥러닝 모델은 자연재해 피해를 줄이고 재난관리를 개선할 수 있는 충분한 잠재력을 가질 것으로 기대된다.

  • PDF

Passenger's Right to Compensation in relation to Delayed Flights - From the perspective of EU case law - (운항지연에 따른 승객의 보상청구권 - EU 및 프랑스 판례를 중심으로 -)

  • Lee, Chang-Jae
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.249-277
    • /
    • 2015
  • Regulation (EC) No 261/2004 ("Regulation") is a common rule on compensation and assistance to passengers in the event of denied boarding and of cancellation or long delay of flights. In some recent cases of European nations, passengers sued the air carrier in order to obtain monetary compensation under Article 7(1) of the Regulation. Some courts dismissed the actions on the grounds that, unlike denied boarding or cancellation of the flight, the Regulation provides no compensation in relation to delayed flights. However, Court of Justice of the European Union(CJEU) ruled that Regulation 261/2004 must be interpreted to mean that passengers whose flights are delayed have a right to compensation in cases when the loss of time is equivalent to, or is in excess of three hours - where the passengers eventually reached their final destination three hours or more later than the originally scheduled arrival time. It is true that a strict interpretation of the regulation would suggest that passengers whose flight has merely been delayed are not entitled to compensation. They should only be offered assistance in accordance with the Articles 6 and 9. Nevertheless, the Court recognized the same right to the same compensation for passengers of flights delayed by more than three hours as that explicitly provided for passengers of cancelled flights. On the one hand, the Court bases this ruling on the recitals of the Regulation, in which the legislature links the question of compensation to that of a long delay, while indicating that the Regulations seek to ensure a high level of protection for passengers regardless of whether they are denied boarding or their flight is cancelled or delayed. On the other hand, the Court interprets the relevant provisions of the Regulation in light of the general principle of equal treatment. Furthermore, the Court delivered a ruling that the loss of time inherent in a flight delay, which constitutes an inconvenience within the intention of Regulation No 261/2004 and which cannot be categorized as 'damage occasioned by delay' within the meaning of Article 19 of the Montreal Convention, cannot come within the scope of Article 29 of that convention. Consequently, under this view, the obligation under Regulation No 261/2004 intended to compensate passengers whose flights are subject to a long delay is in line with Article 29 of the Montreal Convention. Although the above interpretation of the Court can be a analogical interpretation, the progressive attitude of the Regulation and the view of Court forward to protect passengers' interest is a leading role in the area of international air passenger transportation. Hopefully, after the model of the positive support in Europe, Korea can establish a concrete rule for protecting passengers' right and interest.

A Study on the Concentration of Nanoparticles and Heavy Metals in Indoor/Outdoor Air in a University Administrative Public Office (대학교 행정실 실내 외 공기 중 나노입자와 중금속 농도에 관한 연구)

  • Choi, Su-Hyeon;Im, Ji-Young;Park, Hee-Jin;Chung, Eun-Kyung;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.493-502
    • /
    • 2012
  • Objectives: The purpose of this study is to investigate the mass concentration of nanoparticles and understand the characteristics of elements of heavy metal concentrations within nanoparticles in the air using Micro-Orifice Uniform Deposit Impactor Model-110 (MOUDI-110), based on indoor and outdoor air. Methods: This Study sampled nanoparticles using MOUDI-110 indoors (office) and outdoors at S University in Asan, Korea in order to reveal the concentration of nanoparticles in the air. Sampling continued for nine months (10 times indoors and 14 times outdoors) from March to November 2010. Mass concentrations of nanoparticle and concentrations of heavy metals (Al, Mn, Zn, Ni, Cu, Cr, Pb) were analyzed. Results: Indoors, geometric mean concentration of nanoparticles ranged in size from 0.056 ${\mu}m$ to 0.10 ${\mu}m$ and those of 0.056 ${\mu}m$ or less recorded 0.929 ${\mu}g/m^3$ and 1.002 ${\mu}g/m^3$, respectively. On the other hand, the levels were lower outdoors with 0.819 ${\mu}g/m^3$ and 0.597 ${\mu}g/m^3$. Mann-Whitney U tests showed that the difference between the indoors and the outdoors was statistically meaningful in terms of particles of 0.056 ${\mu}m$ or less (p<0.05) in size. These results are possibly influenced by the use of printers and duplicators as the factor that increased the concentration of nanoparticles. In seasonal concentration distribution, the level was higher during the summer compared to in the autumn. Those of 0.056 ${\mu}m$ or less in size presented a statistically meaningful difference during the summer (p<0.05). These results may be influenced by photochemical event as the factor that makes the levels high. Regarding zinc, among the other heavy metals, the fine particles ranged in size from 0.056 ${\mu}m$ to 0.10 ${\mu}m$ and those of 0.056 ${\mu}m$ or less recorded 1.699 $ng/m^3$ and 1.189 $ng/m^3$ in the outdoors. In the indoors, the levels were lower, with 0.745 $ng/m^3$ and 0.617 $ng/m^3$. Cr and Ni at the size of 0.056 ${\mu}m$ or less, both of which have been known to pose severe health effects, recorded higher concentrations indoors with 0.736 $ng/m^3$ and 0.177 $ng/m^3$, compared to 0.444 $ng/m^3$ and 0.091 $ng/m^3$ outdoors. By season, Zn, Ni, Cu and Pb posted a high level of indoor concentration during the fall. As for Cr, the level of concentration indoors was higher than outdoors both during the summer and the autumn. Conclusion: This study indicates the result of an examination of nano-sized particles and heavy metal concentrations. It will provide useful data for the determination of basic nanoparticle standards in the future.

A STUDY ON TEMPERATURE VARIATION OF THE UPPER THERMOSPHERE IN THE HIGH LATITUDE THROUGH THE ANALYSIS OF 6300 $\AA$ AIRGLOW DATA (6300 $\AA$ 대기광 자료 분석을 통한 고위도 열권 상부에서의 온도 변화)

  • 정종균;김용하;원영인;이방용
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.94-108
    • /
    • 1997
  • The temperature of the upper thermosphere is generally varied with the solar activity, and largely with geomagnetic activity in the high latitude. The data analyzed in this study are acquired at two ground stations, Thule Air Base($76,5{deg} N, 68.4{deg} W, A = 86{deg}$) and $S{psi}ndre Str{psi}mfjord (67.0{deg} N, 50.9{deg} W, A = 74{deg}$), Greenland. Both stations are located in the high latitude not only geographically but also geomagnetically. The terrestrial night glow at 6300 ${angs}$ from atomic oxygen has been observed from the two ground-based Fabry-Perot interferometers, during periods of 1986~1991 in Thule Air Base and 1986~1994 in $S{psi}ndre Str{psi}mfjord$. Some features noted in this study are as follows: (1) The correlation between the solar activity and the measured thermospheric temperature is highest in the case of $3{leq}Kp{leq}4$ in Thule, and increases with the geomagnetic activity in $S{psi}ndre Str{psi}mfjord$. (2) The measured temperatures at Thule is generally higher than those at $S{psi}ndre Str{psi}mfjord$, but the latter shows steeper slope with the solar activity. (3) The harmonic analysis shows that the diurnal variation(24hrs) is the main feature of the daily temperature variation with a temperature peak at about 13-14 LT (LT=UT-4). However, the semi-diurnal variation is evident during the period of weak solar activity. (4) Generally the predicted temperatures from both MSIS86 and VSH models are lower than the measured temperature, and this discrepancy grows as the solar activity increases. Therefore, we urge modelers to develope a new thermospheric model utilizing broader sets of measurements, especially for high solar activity.

  • PDF

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.