• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.037 seconds

A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV (PIV에 의한 냉장고 기류특성 평가방법)

  • Kim, Seok-Ro;Doh, Deog-Hee;Lee, Jae-Keun;Kim, Kyung-Chun
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

Estimating Price Elasticities of Domestic Air Transport Demand by Stated Preference Technique (Staled Preference 방법론에 의한 국내선 항공수요의 가격탄력성 추정)

  • 이성원;이영혁;박지형
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2000
  • This study analyzes the price elasticities of airline Passenger demand through the 'Stated Preference' technique which uses survey data. Because the domestic airfare has been regulated by the government. it is not easy to derive Price elasticity through the usual regression analysis with aggregate data and thus a special methodology is required for elasticity estimation. Therefore, in this study we estimated the Price elasticities of domestic air passenger demand and the modal share change rates to the alternative modes with logit model and sample enumeration method, by analyzing the survey data on air Passengers' demand behavior about the mode choice between air-rail. air-bus, and air-car. As the results, the estimated price elasticities are in the range of -0.6~-0.9, and rail is mainly chosen as an alternative mode. bus is chosen Partly, and car is barely used.

  • PDF

Simulation and Model Validation of a Pneumatic Conveying Drying for Wood Dust Particles

  • Bhattarai, Sujala;Kim, Dae-Hyun;Oh, Jae-Heun
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.82-89
    • /
    • 2012
  • Purpose: The simulation model of a pneumatic conveying drying (PCD) for sawdust was developed and verified with the experiments. Method: The thermal behavior and mass transfer of a PCD were modeled and investigated by comparing the experimental results given by a reference (Kamei et al. 1952) to validate the model. Momentum, energy and mass balance, one dimensional first order ordinary differential equations, were coded and solved into Matlab V. 7.1.0 (2009). Results: The simulation results showed that the moisture content reduced from 194% to 40% (dry basis), air temperature decreased from $512^{\circ}C$ to $128^{\circ}C$ with the particle residence time of 0.7 seconds. The statistical indicators, root mean square error and R-squared, were calculated to be 0.079, and 0.998, respectively, between the measured and predicted values of moisture content. The relative error between the measured and predicted values of the final pressured drop, air temperature, and air velocity were only 8.96%, 0.39% and 1.05% respectively. Conclusions: The predicted moisture content, final temperature, and pressure drop values were in good agreement with the experimental results. The developed model can be used for design and estimation of PCD system for drying of wood dust particles.

Estimation of Wall Wetting Fuel at Intake Port and Model Based Prediction A/F in a S.I. Engine (가솔린 엔진에서 액막 연료량 추정 및 이를 이용한 공연비 예측에 관한 연구)

  • 황승환;이종화;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.116-122
    • /
    • 1999
  • According to the stringent exhaust emission regulation, precise control of air fuel ratio is one of the most important issues on gasoline engine. Although many researches have been carried out to identify the fuel transport phenomena in a port fueled gasoline engine, complexity of fuel film behavior in the intake port makes it difficult. The fuel film behavior was investigated recently by using visualization method and these gave us qualitative understanding. The purpose of this study is to estimate of wall wetting fuel in the intake port and the inducted fuel mass was predicted by using wall wetting fuel model . The model coefficient($\alpha$,$\beta$) and fuel film mass on the port wall were determined from measured in-cylinder HC concentration using FRFID after injection off. The fuel film mass was increased, but $\alpha$(ratio of directly inducted fuel mass into cylinder from injected fuel mass) was decreased with increasing load at the same engine speed. $\beta$is nearly constant value(0.8~0.9). when injected fuel mass is varied at 1500rpm , the calculated air fuel ratio using well wetting fuel model was nearly the same as measured by UEGO.

  • PDF

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln (로타리 킬른의 장입 특성이 온도분포에 미치는 영향)

  • Park, Jong-Seok;Chun, Chul-Kyun
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.3
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

Experimental Study on Fuel-Air Mixing Using Flat Plate/Cavity in Supersonic Flow (초음속 유동장 내 평판/cavity를 이용한 연료-공기 혼합의 실험적 연구)

  • Kim, Jeong-Woo;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.319-322
    • /
    • 2006
  • Rapid mixing of air-fuel (<1 ms) is needed to accomplish supersonic combustion. In this experiment, helium was injected laterally in to the Mach 1.92 air flow. 2 kinds of model, flat plate/cavity, were used in this experiment and images were taken by schlieren visualization. Pressure was affected by shock structure in the supersonic duct, and penetration height was increased by increasing J. Penetration height was higher in the cavity model than flat plate model.

  • PDF

Dynamic Analysis of Air Circuit Breaker with Spring-Actuated Linkage (스프링구동 링크를 가진 기중 회로차단기의 동적 분석)

  • 안길영;권병희;오일성;윤영관;최종웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.812-815
    • /
    • 1997
  • A dynamic model of air circuit breaker with a spring-actuated linkage is derived, and its validation for analysis and design, particularly appropriateness for an analysis of high-speed motion behavior are checked through experiments. The dynamic model is developed through the modeling process based on ADAMS and Pro/Engineer. The simulation results of derived dynamic models for the rapid closing and opening operations are compared with actual responses using a high-speed camera and investigated to validate their usefulness.

  • PDF

The study for the aerodynamic effects of air-shafts in the railway tunnel (철도터널 통풍공의 공기역학적 성능에 대한 연구)

  • Kim, Dong-Hyeon;Kang, Bu-Byoung;Shin, Min-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.341-348
    • /
    • 2001
  • The purpose of present study is to investigate for reducing pressure fluctuations in the case of installing the air-shafts on the side wall of the tunnel with small cross-sectional area on conventional line. Experiments were performed with a 1/61-scale moving model rig for the tunnel of 0.764 km length in the condition of tunnel cross-section area of $28 m^2$. According to the results, the maximum pressure fluctuation is reduced by 45 % for 19 air-shafts. This results have the speed-up effects of about 33.4 km/h for the train running in tunnel.

  • PDF

Mathematical Modeling of the Effect of External Radiative Heating on Heat and Mass Transfer Between A Semi-transparent Diesel Fuel Droplet and Quiescent Air

  • Woo In-Sung;Choi Sung-Eul;Stamatov Venelin
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2004
  • The system considered in this model consists of a single, semi- transparent, diesel fuel droplet, which is immobile in the heating area and surrounded by a quiescent air. A uniform external radiation field surrounds the droplet. Results from mathematical simulation suggest that because of the higher surface temperature, the external radiative heating of the droplet can promote an earlier ignition of the fuel vapour/air mixture. The radiative heating of the droplet increases the mass transfer from the droplet to the surrounding gas-phase, thus, decreasing the heterogeneity of the fuel droplet/air system.