• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.037 seconds

Study on the Performance Evaluation of the Air-tightened Exhibition Case in the Museum (밀폐형 전시케이스의 기밀성능 평가방법 연구)

  • 김재용;노광철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.184-190
    • /
    • 2002
  • This study was undertaken to judge the quality of air-tightened exhibition cases. Exhibition cases for artifacts display provide a layer of protection between the interior conditions in the exhibition case and the exterior fluctuating conditions of temperature and relative humidity in the museum environment. An infiltration model of the exhibition case was developed through the experimental measurements to calculate the number of air change rate in the exhibition case undergoing in a day, which represents the airtightness of the exhibition case. The results indicate that tighter exhibition cases provide greater protection against the fluctuating conditions of temperature and humidity outside. When the temperature and humi- dity difference between the exhibition case in-and-out is larger, some absorption materials should be applied to control the environmental conditions in the exhibition case.

Study on Thermal Property in Urban Area - Quantitative Estimation of Heat Island in Urban area using the Simple Urban Canopy Model - (도심지의 온열성상에 관한 연구 - 공조배열량의 감소에 따른 도심지 온열환경의 변화 -)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1190-1196
    • /
    • 2004
  • Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we propose numerical model in order to analyze quantitative effects of building environmental factors on the heat island phenomenon in urban area. In this paper, we propose a predicting model to analyze the heat island phenomenon quantitatively. Using this model, numerical simulation is performed in order to analyze quantitative effects of many factor on the heat island phenomenon.

A Study on the Variation of Air Pollutants Emission Rates for Different Traffic Signal System in Metropolitan Area (대도시 교통신호시스템에 따른 대기오염물질 배출량 변화에 관한 연구)

  • 홍민선;우완기;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.93-100
    • /
    • 1993
  • This study was carried out to investigate the relationship between the traffic signal systmes and the air pollutants emitted by the motor vehicles at Kangnam Intersection. One of the most important measures of effectiveness (MOE) in traffic studies is the delay to vehicles in the system. Delay represents indirect costs to the motorist in terms of time loss and a direct cost in terms of fuel consumption during idling. The results of TRANSYT-7F modeling was correlated among delay, fuel consumption and total travel tiem. Air pollutants emission rate can be calculated by the results of modeling and the Korean type emission factor. As expected the highest emissions, for air pollutants, are observed during the morning rush hours (07 : 00-10 : 00). For better results of modeling, the TRANSYT-7F model needs to modify for the Korean type of traffic model. The results of this study indicate that the variation of air pollutants emission rates were closely related to the traffic signal system.

  • PDF

The Spatial Charateristics of Ventilation Efficiency (실내환기효율의 공간적 변화특성에 관한 연구)

  • 김신도;김태식;이희관;이정주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.236-241
    • /
    • 1993
  • Recently, with the ourdoor air pollution, the indoor air pollution devided into living environment and working environment are raised as the problem of indoor space. Also, the more time lived in indoor space, the larger the influence of indoor air pollution. Therefore in this study, the spatial variation of ventilation efficiency was estimated through the experiment using a physical model. The experiment using a physical model. The experiment was conducted in two category; the central zone of ventilated air flow and the corner zone. As the result of experiment, high ventilation efficiency (90$\sim$108%) was shown in the central zone of ventilated air flow. Whereas low ventilation efficiency (46$\sim$77%) was shown in the corner zone. In conclusion, when the designing of ventilation was planned, the zone showed low ventilation efficiency should be considered.

  • PDF

Thermodynamic Modeling of Parallel Flow Condenser for Automotive Air Conditioning System (자동차용 평행류 응축기의 열성능 모델링)

  • 김일겸;고재윤;박상록;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.771-779
    • /
    • 2001
  • In this study, a simulation program has been developed to predict the performance of a parallel flow condenser of an air conditioning system for an automobile. The well-known correlations for he heat transfer rates and the pressure drops are included in this model. It is fond that the numerical model can predict the heat transfer rate and the pressure drop accurately. As the condensing pressure increases of fixed air inlet temperature, the heat transfer rate increases and the pressure drop decreases. The effect of he degree of subcooling on the performance of the condenser is greater than that of the degree of super-heating because the ratio of the area occupied by he tow-phase refrigerant the total area is significantly affected by he degree of subcooling rather than the degree of superheating.

  • PDF

Analytic and Numerical Study for air Bubble Defect of UV-NIL Process (UV-NIL 공정의 기포 결함에 대한 해석적 및 수치적 연구)

  • Seok, Jeong-Min;Kim, Nam-Woong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.473-478
    • /
    • 2012
  • In this paper, the air bubble formation mechanism in the rectangular and triangular line-and-space pattern during dispensing UV Nanoimprint Lithography (UV-NIL) at an atmospheric condition is studied. To investigate the air bubble formation, an analytic model based on geometric approach and a numerical model based on CFD(computational fluid dynamics) were used in the analysis. It was found in the numerical analysis that every time the flow front passed through a corner of the pattern, it proceeded with a newly formed shape, occurring due to interface reconfiguration, since the flow fronts were formed such that they minimized the surface energy. Moreover, the conditions for the air bubble formation were investigated by applying the analytic analysis based on geometric approach and the numerical analysis. Good overall agreement was found between the analytic and numerical analysis.

The aerodynamic performance of air-shafts with different inner diameters in the railroad tunnel (철도터널 통풍공의 내경변화에 따른 공기역학적 성능)

  • Kim, Dong-Hyeon;Kang, Bu-Byoung;Shin, Min-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.578-584
    • /
    • 2001
  • Purpose of the present study is to investigate the aerodynamic performances of air-shafts with different inner diameters in a single track tunnel for reducing pressure fluctuations and micro pressure waves. Three configurations of air-shafts with different inner diameters were examined for comparison of aerodynamic performances. Experiments were performed with a 1/61-scale moving model rig for the tunnel of 0.764 km length and the train of 4 cars per 1 unit. The results showed the reduction effect of the maximum pressure fluctuations in tunnel and micro-pressure waves radiating towards the surroundings from the tunnel exit according to the increase of the diameter of 10 air-shafts spaced equally.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

Thermal and Fluid Analysis on Air Distribution in a Elevator Car (엘리베이터 카 내부 기류분포에 관한 열 유동해석)

  • Chung, Kyung Taek;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2020
  • The purpose of this study is to observe the visualization of the flow field for air flow distributed in the car from the ventilation fan installed in the ceiling of the passenger elevator car through the numerical analysis using computational fluid dynamics. STAR-CCM+, which is a code used for the numerical analysis, was used to predict the airflow distribution inside the elevator car. The numerical analysis of the distribution of the air current in the elevator was carried out. As a result, the analysis results for each point and the visualization of the air current distribution and the temperature distribution in the elevator car and were obtained. It was found that heat transfer was actively occurring inside the car due to the influence of the flow field discharged from the ventilation vent installed in the ceiling in the elevator car, and especially the convection heat transfer of Model-2 was more active than that of Model-1. As a result, the temperature distribution inside the car was found to be relatively low. In addition, the temperature distribution at a cross-section of 1700mm height in the elevator car shows that Model-2 is the location of the ventilation vent which makes people feel more comfortable.

Performance Tests on Parallel Plate Type Solar Air Heater (공기식 평행판형 태양집열기 성능실험)

  • Cha Jong Hee;Song Hi Yul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.4
    • /
    • pp.255-261
    • /
    • 1977
  • This study was concerned with the performance of solar air heater using parallel channels. Heat transmission model was developed and fabricated to increase the economic feasibility for solar heating system by using the cheap zinc plate. The prformance was discussed as a function of mass flow rate, and plate, inlet and outlet temperatures. Experimental results show that heat transmission model is sufficient for the analysis of thermal characteristics of air heater and collection efficiency is better than the domestic water heater, as the range 32-49 percent. Collection efficiency in the 2 layers of glass cover is better than that in 1 layer, so it is considered better to use the 2 layers of glass cover during the cold winter season in Korea.

  • PDF