• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.033 seconds

Parametric Study for Reducing NO and Soot Emissions in a DI Diesel Engine by Using Engine Cycle Simulation (직분식 디젤엔진에서 엔진 매개변수들이 NO 및 soot 배출에 미치는 영향에 대한 수치해석 연구)

  • 함윤영;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.35-44
    • /
    • 2002
  • Engine cycle simulation using a two-zone model was performed to investigate the effect of the engine parameters on NO and soot emissions in a DI diesel engine. The present model was validated against measurements in terms of cylinder pressure, BMEP, NO emission data with a 2902cc turbocharger/intercooler DI diesel engine. Calculations were made for a wide range of the engine parameters, such as injection timing, ignition delay, Intake air pressure, inlet air temperature, compression ratio, EGR. This parametric study indicated that NO and soot emissions were effectively decreased by increasing intake air pressure, decreasing inlet air temperature and increasing compression ratio. By retarding injection timing, increasing ignition delay and applying EGR. NO emission was effectively reduced, but the soot emission was increased.

Fault Detection and Diagnosis of a Constant Volume Air Handling Unit by a Fuzzy Algorithm (퍼지 알고리즘을 이용한 정풍량 공조기의 고장 감지 및 진단)

  • Han Doyoung;Kim Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.444-451
    • /
    • 2005
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this study, partial faults for fans, coils, dampers, and sensors of a constant volume air handling unit were considered. A fuzzy algorithm was developed to detect and diagnose these faults. Diagnostic results by the fuzzy algorithm were compared with those by the model reference algorithm. The fuzzy algorithm showed better results in diagnostic accuracies.

A Comparision of the Breakdown Characteristics for $SF_6$ and I-Air based on Temperature variations (온도변화에 따른 $SF_6$와 I-Air의 절연파괴특성 비교)

  • Park, He-Rie;Kim, Do-Seok;Lee, Sang-Ho;Woo, Sung-Hun;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.235-237
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of l-Air(Imitation Air, $N_2:O_2=79:21$) and $SF_6$ gas based on temperature variations in experimental GIS model by applying negative DC voltage. The breakdown charcteristics were compared with gas pressures and each gas already entered in GIS model. The characteristics of l-Air and $SF_6$ were different in specific temperature range that $SF_6$ gas was being liquefied. The breakdown voltages of $SF_6$ were more higher than l-Air except for 4[atm] at $-10{\sim}0[^{\circ}C]$.

  • PDF

Investigation of NO Formation Characteristics in Multi Staged Air Combustor (공기 다단 연소기 화염의 NO 발생특성에 관한 연구)

  • Kim, Han-Seok;An, Guk-Yeong;Baek, Seung-Uk;Yu, Myeong-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1594-1605
    • /
    • 2001
  • In this study, a numerical simulation was developed which was capable of predicting the characteristics of NO formation in pilot scale combustor adopting the air-staged burner flame. The numerical calculation was constructed by means of establishing the mathematical models fur turbulence, turbulent combustion, radiation and turbulent nitric oxide chemistry. Turbulence was solved with standard k-$\xi$ model and the turbulent combustion model was incorporated using a two step reaction scheme together with an eddy dissipation model. The radiative transfer equation was calculated by means of the discrete ordinates method with the weighted sum of gray gases model for CO$_2$and H$_2$O. In the NO chemistry model, the chemical reaction rates for thermal and prompt NO were statistically averaged using the $\beta$ probability density function. The results were validated by comparison with measurements. For the experiment, a 0.2 MW pilot multi-air staged burner has been designed and fabricated. Only when the radiation was taken into account, the predicted gas temperature was in good agreement with the experimental one, which meant that the inclusion of radiation was indispensable for modeling multi-air staged gas flame. This was also true of the prediction of the NO formation, since it heavily depended on temperature. Subsequently, it was found that the multi-air staged combustion technique might be used as a practical tool in reducing the NO formation by controlling the peak flame temperature.

Development and Evaluation of Statistical Prediction Model of Monthly-Mean Winter Surface Air Temperature in Korea (한반도 겨울철 기온의 월별 통계 예측 모형 구축 및 검증)

  • Han, Bo-Reum;Lim, Yuna;Kim, Hye-Jin;Son, Seok-Woo
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.153-162
    • /
    • 2018
  • The statistical prediction model for wintertime surface air temperature, that is based on snow cover extent and Arctic sea ice concentration, is updated by considering $El-Ni{\tilde{n}}o$ Southern Oscillation (ENSO) and Quasi-Biennial Oscillation (QBO). These additional factors, representing leading modes of interannual variability in the troposphere and stratosphere, enhance the seasonal prediction over the Northern Hemispheric surface air temperature, even though their impacts are dependent on the predicted month and region. In particular, the prediction of Korean surface air temperature in midwinter is substantially improved. In December, ENSO improved about 10% of prediction skill compared without it. In January, ENSO and QBO jointly helped to enhance prediction skill up to 36%. These results suggest that wintertime surface air temperature in Korea can be better predicted by considering not only high-latitude surface conditions (i.e., Eurasian snow cover extent and Arctic sea ice concentration) but also equatorial sea surface temperature and stratospheric circulation.

Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • v.1 no.1
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.

  • PDF

Numerical Analysis of Wintertime Air Pollution in East Asia Region Using Long-Range Transport Model

  • Jang, Eun-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • In order to understand the wintertime intermittent characteristics of the trans-boundary air pollutant transport observed in East Asia, a numerical simulation of the long-range transport of pollutants was applied using an atmospheric transport model(STEM-II). The numerical simulation was carried out for the entire month of January 1997 and specific atmospheric aerosol (including sulfate, nitrate, and other ion compounds0 observation data were compared from four observation sites(Cheju Island, Kanghwa Island, Dazaifu, and Fukue Island). The observation data revealed that concentration peaks were intermittently observed at 3 to 4-day intervals plus the four observation sites exhibited a very similar spatial variation. The horizontal and spatial scale of the heavily polluted air masses was analyzed based on numerical results. The mechanism of the intermittent transport of air pollutants was clearly explained by a comparison of the observed data with the numerical output. It was found that the wind pattern variations associated with the synoptic scale pressure system changes play an extremely important role in the transport of pollutants in this region.

  • PDF

Air Resistance Due to the Deflector Configuration of Commonly Used Largetrucks (상용 대형 트럭의 디플렉터 형상에 따른 공기저항력)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.138-144
    • /
    • 2014
  • This study investigates the air resistance due to deflector configurations of commonly used largetrucksat a driving speedof 80 km/h. Of the 6 models that are considered, the drag causedby the pressure on the front part of the trailer is largest for model 1. For model 1, the lift caused by the difference between the velocities of the upper and lower streams isgreatest amongall the models. Model 6 has the least resistance against the flow stream consideringthedrags and lifts of theflow models. Anoptimal design can be obtainedby investigating thesimulation analysis ofvarious deflector configurationsfor the upper part of largetrucks; this optimum deflector configuration will help reduce the air resistanceon large trucks.

Data-Based Model Approach to Predict Internal Air Temperature in a Mechanically-Ventilated Broiler House (데이터 기반 모델에 의한 강제환기식 육계사 내 기온 변화 예측)

  • Choi, Lak-yeong;Chae, Yeonghyun;Lee, Se-yeon;Park, Jinseon;Hong, Se-woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.5
    • /
    • pp.27-39
    • /
    • 2022
  • The smart farm is recognized as a solution for future farmers having positive effects on the sustainability of the poultry industry. Intelligent microclimate control can be a key technology for broiler production which is extremely vulnerable to abnormal indoor air temperatures. Furthermore, better control of indoor microclimate can be achieved by accurate prediction of indoor air temperature. This study developed predictive models for internal air temperature in a mechanically-ventilated broiler house based on the data measured during three rearing periods, which were different in seasonal climate and ventilation operation. Three machine learning models and a mechanistic model based on thermal energy balance were used for the prediction. The results indicated that the all models gave good predictions for 1-minute future air temperature showing the coefficient of determination greater than 0.99 and the root-mean-square-error smaller than 0.306℃. However, for 1-hour future air temperature, only the mechanistic model showed good accuracy with the coefficient of determination of 0.934 and the root-mean-square-error of 0.841℃. Since the mechanistic model was based on the mathematical descriptions of the heat transfer processes that occurred in the broiler house, it showed better prediction performances compared to the black-box machine learning models. Therefore, it was proven to be useful for intelligent microclimate control which would be developed in future studies.

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.