• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.04 seconds

Experimental investigation of frictional resistance reduction with air layer on the hull bottom of a ship

  • Jang, Jinho;Choi, Soon Ho;Ahn, Sung-Mok;Kim, Booki;Seo, Jong Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.363-379
    • /
    • 2014
  • In an effort to cope with recent high oil price and global warming, developments of air lubricated ships have been pursued to reduce greenhouse gas emissions and to save fuel costs by reducing the frictional resistance. In this study, reduction in the frictional resistance by air lubrication with air layers generated on the lower surface of a flat plate was investigated experimentally in the large water tunnel of SSMB. The generated air layers were observed, and changes in the local frictional drag were measured at various flow rates of injected air. The results indicated that air lubrication with air layers might be useful in reducing the frictional resistance at specific conditions of air injection. Accordingly, resistance and self-propulsion tests for a 66K DWT bulk carrier were carried out in the towing tank of SSMB to estimate the expected net power savings.

Capillary Bundle Model for the Estimation of Air-water Interfacial Area and the Gas-filled Pore Size Distribution in Unsaturated Soil (모세관 모델을 이용한 불포화토양의 물-가스 접촉면적 및 가스공극 크기분포의 계산 및 검증)

  • Kim, Heonki
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Air-water interfacial area is of great importance for the analysis of contaminant mass transfer processes occurring in the soil systems. Capillary bundle model has been proposed to estimate the specific air-water interfacial areas in unsaturated soils. In this study, the measured air-water interfacial areas of a soil (loam) using the gaseous interfacial tracer technique were compared to those from capillary bundle model. The measured values converged to the specific solid surface area (7.6×104 ㎠/㎤) of the soil. However, the simulated air-water interfacial areas based on the capillary bundle model deviated significantly from those measured. The simulated values were substantially over-estimated at low end of the water content range, whereas the model under-estimated the air-water interfacial area for the most of the water content range. This under-estimation is considered to be caused by the nature of the capillary bundle model that replaces the soil pores with a bundle of glass capillaries and thus no surface roughness at the inner surface of the capillaries is taken into account for the estimation of the air-water interfacial area with the capillary bundle model. Subsequently, appropriate correction is necessary for the capillary bundle model to estimate the air-water interfacial area in soils. Since the soil-moisture release curve data is the basis of the capillary bundle model, the model can be of use due to its simplicity, while the gaseous tracer technique requires complicated experimental equipment followed by moment analysis of the breakthrough curves. The size distribution profile of the pores filled with gas estimated by the water retention curve was found to be similar to that of particle size at different size range. The shifted distribution of gas-filled pores toward smaller size side compared to the particle size distribution was also found.

A Study on Air Pollution Measurement Model in Inchon City (인천직할시 대기오염 측정 MODEL의 개발)

  • 김윤선;이동인
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.102-108
    • /
    • 1996
  • Urban air pollution has been gradually increasing by the increase of population and vehicles recently. There are shown larger effects of air pollution in Incheon city which has more than 2 million people and has heavy holding amounts ratio of transportation vehicles as compared with other cities. However, it is very difficult to predict the air quality condition of their moving pollutants. Therefore, in this study air pollution measuring model was designed to estimate the air pollution level by line sources(transprtation vehicles ) of air pollutants and to detect the $NO_x$ emission amounts in ordinary times, and it became clear that it is functionally operative.

  • PDF

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn;Tripak, Kasem;Saelao, Jeerawan
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.

Impact Analysis of Air Quality of Mobile Sources using Microscopic Emission and Dispersion Model (미시적 탄소배출량 및 대기확산 모형을 이용한 이동오염원에 의한 대기 질 영향 분석)

  • Yang, Choong Heon;Yang, Inchul;Yoon, Chun Joo;Sung, Jung Gon
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2013
  • PURPOSES : The objective of this study is to investigate the capability of the combined model of traffic simulation, emission and air dispersion models on the impact analysis of air quality of mobile sources such as vehicles. METHODS : The improvement of the quality of life brings about the increasing interest of the public environment. Many endeavors including the travel demand management, the application of the state-of-the-art ITS technologies, the promotion of eco-friendly vehicles have been tried in transportation area to reduce the modal emissions. Especially, it is expected that the increasing number of eco-friendly vehicles in the road network would be able to reduce the pipe-tail emissions tremendously. From this perspective, we have performed a study on the impact analysis of the popularization of the eco-friendly vehicle in the place of the fossil fuel energy powered vehicles on the surrounding air quality using the combined framework of microscopic traffic simulation, emission and air dispersion model. RESULTS : The combined model successfully captured the effect of moving to the eco-friendly vehicles on the air quality, and the results showed that the increasing usage of eco-friendly vehicles can improve the surrounding air quality tremendously and that the air dispersion model plays a crucial role in the investigation of the air quality change around the main corridor. CONCLUSIONS : This study demonstrated the capability of the combined model showing the spatio-tempral change of emission concentration.

On the Drag Reduction of a Passenger Ship with Air Cavity

  • Jang, Jin-ho;Kim, Hyo-chul;Lee, Seung-Hee
    • Journal of Ship and Ocean Technology
    • /
    • v.3 no.4
    • /
    • pp.15-22
    • /
    • 1999
  • It is known that lubrication effect of an air cavity can reduced a drag of a ship. The present study intends to utilize the phenomena for the drag reduction of a passenger ship now operating in a lake. A scaled model of the model when air cavities are formed under the bottom of the model. Model experiments have been performed to determine adequate air supply rates, proper shapes and locations of air supply nozzles. It is shown that energy saving of mere than 10% can be achieved at the design speed of the ship even after excluding additional power consumed for air supplying. Multiple air supply nozzles, if allocated properly, are more effective than single one in resistance reduction of the ship.

  • PDF

Construction of Map for Transient Condition of a Sl Engine and Refinement of Intake Air Model & Fuel Model (가솔린 엔진의 비정상 상태에 대한 Map 구성과 공기 및 연료 모델 개선)

  • 심연섭;강태성;강승표;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.1-8
    • /
    • 2002
  • For gasoline engines, a three-way catalytic converter that has the maximum efficiency at stoichiometric air/fuel ratio is used to clean up the exhaust gas. So a precise air/fuel ratio control is necessary to maximize the catalytic conversion efficiency, For a transient condition, a fred-forward air/fuel ratio control method that estimates the air mass inducted into a cylinder is being used. In this study, a fuel injection map that makes an accurate air/fuel ratio control possible was constructed for the very same transient condition. For the same condition above, intake air model and fuel model were refined so that fuel injection values based on air mass through a throttle valve and intake manifold pressure are equal to the map values.

A Chemical Kinetic Model Including 54 Reactions for Modeling Air Nonequilibrium Inductively Coupled Plasmas

  • Yu, Minghao;Wang, Wei;Yao, Jiafeng;Zheng, Borui
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1519-1528
    • /
    • 2018
  • The objective of the present study is the development of a comprehensive air chemical kinetic model that includes 11 species and 54 chemical reactions for the numerical investigation of air nonequilibrium inductively coupled plasmas. The two-dimensional, compressible Navier-Stokes equations coupled with the electromagnetic-field equations were employed to describe the fundamental characteristics of an inductive plasma. Dunn-Kangs 32 chemical-reaction model of air was reconstructed and used as a comparative model. The effects of the different chemical kinetic models on the flow field were analyzed and discussed at identical/different working pressures. The results theoretically indicate that no matter the working pressure is low or high, the use of the 54 chemical kinetic model presented in this study is a better choice for the numerical simulation of a nonequilibrium air ICP.

Sensitivity Analysis of Air Pollutants Dispersion Model in the Road Neighboring Area Due to the Line Source -The Object on ISCST3, CALINE4 Model- (선 오염원에 의한 도로변 지역으로의 대기확산모델의 민감도 분석 - ISCST3, CALINE4 모델을 중심으로 -)

  • Ahn, Won-Shik;Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.715-723
    • /
    • 2007
  • The air pollutant emission is mainly caused by line sources in urban area. For example, the annually totaled air pollutant emission is known to consist of about 80% of line sources in Daegu. Hence, the appropriate assessment on the air pollutants of line sources is very important for the atmospheric environmental management in urban area. In this study, we made a comparative study to evaluate suitable dispersion model for estimating the air pollution from line sources. Two air pollution dispersion models, ISCST3 and CALINE4 were the subject of this study. The results were as follows; In the assessment of air pollution model, ISCST3 was found to have 4 times higher concentration than CALINE4. In addition, actual data obtained by measurement and estimated values by CALINE4 were generally identical. The air pollution assessment based on ISC3 model produced significantly lower values than actual data. The air pollution levels estimated by ISCST3 were very low in comparison with the observational values.

Cooling Simulation for Fixed-Bed of Rough Rice (벼 퇴적층 냉각 시뮬레이션)

  • 김동철;김의웅;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • The objective of this study were to develop a cooling simulation model for fixed-bed of rough rice and to analyze the factors affecting cooling time of rough rice. A computer simulation model based on equilibrium conditions between grain and air was developed to predict temperature and moisture content changes during cooling of rough rice. the result of t-test showed that there were no significant differences between predicted and measured temperature changes on significance model agreed well with measured values. This cooling simulation model was applied to analyze the effect of some factors, such as air flow rate, cooling air temperature and humidity, initial grain temperature and moisture content, and bed depth, on cooling time of rough rice. Cooling rate increased with increase of air flow rate and bed depth whereas it decreased with increase of cooling air temperature and humidity and initial grain temperature. Among these factors, the most important factor was air flow rate. Specific air flow rate of 0.35㎥/min㎥ was required for cooling rough rice in 24 hours.

  • PDF