• Title/Summary/Keyword: testing system

Search Result 5,279, Processing Time 0.043 seconds

Studies on the Anticancer Effect of Broussonetia kazinoki Extracts (닥나무(Broussonetia kazinoki) 추출물의 항암효과에 관한 연구)

  • 민경진;정승희;구성자
    • Korean journal of food and cookery science
    • /
    • v.15 no.3
    • /
    • pp.231-237
    • /
    • 1999
  • The anticancer effect of the bark of Broussonetia kazinoki root extracts (hexane. chloroform, ethylacetate, butanol, aqueous) were studied. The cytotoxicity by MTT assay and inhibitory effect on the growth of sarcoma 180 cells were tested in vitro. The reduction rate of the tumor formation and spleen/body weight rate on BALB/c mouse were tested in vivo. From the tests, each fraction showed the cytotoxic effect against the sarcoma 180 cells. In addition, as the concentration of the fractions increased, cytotoxic effect tendency increased as well. The cytotoxic rate of the hexane, chloroform, ethylacetate, butanol and aqueous fractions showed by 58.7%, 40.1%, 75.7%, 52.6% and 62.7% respectively after testing by MTT assay system. And sarcoma 180 cells were incubated for 6 days at 37$^{\circ}C$ with various concentrations of each fraction. As the incubation days go on, the number of cells increased, while the inhibition rate on the growth of sarcoma 180 cells were decreased. Especially the ethylacetate fraction at the concentration of 1.0 mg/ml strongly inhibited the growth of sarcoma 180 cells by 74% compared with the control for a day 37$^{\circ}C$ The hexane, chloroform, ethylacetate, butanol and aqueous fractions inhibited on the growth of sarcoma 180 cells by 31%, 19%, 60%, 30% and 42% respectively, when sarcoma 180 cells has been incubated for 6 days at 37$^{\circ}C$. The each fraction exhibited the antitumor effect in vivo. The ethylacetate fraction reduced the tumor formation by 41% compared with the control, when sarcoma 180 cells were injected subcutaneously into the left groin of BALB/c mice. Also spleen/body weight rate of ethylacetate fraction was increased by 2.10% compared with the control (1.08%). And it is considered that there would be no toxic effect caused by each fraction of body weight and organ as there was on more changes in mouse' weight compared with the control.

  • PDF

Inhibitory Effect of Ophioglossum vulgatum on Free Radical and MMP Expression in UV-irradiated Human Dermal Fibroblasts (병이소초 추출물의 항산화 및 MMP 발현 저해 효과)

  • Kim, Jin-Hwa;Oh, Jung-Young;Lee, Geun-Soo;Zhang, Yong-He;Pyo, Hyeong-Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.4
    • /
    • pp.287-292
    • /
    • 2009
  • Human skin is constantly exposed to environmental irritants such as smoke, chemicals and ultraviolet (UV). Free radicals and reactive oxygen species (ROS) caused by these environmental irritants play critical roles in cellular damage. In this study, to investigate the skin cell protective effect of Ophioglossum vulgatum extract, we investigated its effects on intercellular antioxidative activity and UVA-induced MMP expression in human dermal fibroblasts (HDFs). The dried O. vulgatum was extracted in a mixture of ethanol and water (1 : 1) for 24 h at room temperature. The extract was filtered and concentrated in vacuo and lyophilized. For testing intracellular ROS scavenging activity the cultured HDFs were analyzed by increase in DCF fluorescence upon exposure to UVB $20\;mJ/cm^2$. After treatment of O. vulgatum extracts, intracellular ROS levels were measured by luminescence spectrophotometer. Enzyme linked immuno sorbent assay (ELISA), and RT-PCR techniques were used for evaluating the effects of O. vulgatumon on MMP protein and mRNA expression in UVA irradiated HDFs. O. vulgatum extract was found to have ROS scavenging activity with the $IC_{50}$ values of $18.2\;{\mu}g/mL$ against superoxide radicals in the xanthine/xanthine oxidase system. After treatment of O. vulgatum extracts, the oxidation of CM-DCFDA was inhibited effectively and O. vulgatum extracts showed a potent free radical scavenging activity by 30.4 % at $100\;{\mu}g/mL$ in UVB-irradiated HDFs. UVA induced MMP protein expression was reduced 37.7 % by treatment with O. vulgatum extract, and MMP-1 mRNA expression was reduced in a dose-dependent manner. Taken together, these results suggest that O. vulgatum extract prevents the skin cell damage induced by UV irradiation, and implies that O. vulgatum extract may be useful as a new ingredient for anti-aging cosmetics.

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Nuclear Terrorism and Global Initiative to Combat Nuclear Terrorism(GICNT): Threats, Responses and Implications for Korea (핵테러리즘과 세계핵테러방지구상(GICNT): 위협, 대응 및 한국에 대한 함의)

  • Yoon, Tae-Young
    • Korean Security Journal
    • /
    • no.26
    • /
    • pp.29-58
    • /
    • 2011
  • Since 11 September 2001, warnings of risk in the nexus of terrorism and nuclear weapons and materials which poses one of the gravest threats to the international community have continued. The purpose of this study is to analyze the aim, principles, characteristics, activities, impediments to progress and developmental recommendation of the Global Initiative to Combat Nuclear Terrorism(GICNT). In addition, it suggests implications of the GICNT for the ROK policy. International community will need a comprehensive strategy with four key elements to accomplish the GICNT: (1) securing and reducing nuclear stockpiles around the world, (2) countering terrorist nuclear plots, (3) preventing and deterring state transfers of nuclear weapons or materials to terrorists, (4) interdicting nuclear smuggling. Moreover, other steps should be taken to build the needed sense of urgency, including: (1) analysis and assessment through joint threat briefing for real nuclear threat possibility, (2) nuclear terrorism exercises, (3) fast-paced nuclear security reviews, (4) realistic testing of nuclear security performance to defeat insider or outsider threats, (5) preparing shared database of threats and incidents. As for the ROK, main concerns are transfer of North Korea's nuclear weapons, materials and technology to international terror groups and attacks on nuclear facilities and uses of nuclear devices. As the 5th nuclear country, the ROK has strengthened systems of physical protection and nuclear counterterrorism based on the international conventions. In order to comprehensive and effective prevention of nuclear terrorism, the ROK has to strengthen nuclear detection instruments and mobile radiation monitoring system in airports, ports, road networks, and national critical infrastructures. Furthermore, it has to draw up effective crisis management manual and prepare nuclear counterterrorism exercises and operational postures. The fundamental key to the prevention, detection and response to nuclear terrorism which leads to catastrophic impacts is to establish not only domestic law, institution and systems, but also strengthen international cooperation.

  • PDF

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

A Study on Qian Yi(錢乙)'s Medical Though (전을(錢乙)의 의학사상(醫學思想)에 관(關)한 연구(硏究))

  • Oh, Jun Hwan;Kim, Ki Wook;Park, Hyun Kook
    • The Journal of Korean Medical History
    • /
    • v.14 no.2
    • /
    • pp.109-152
    • /
    • 2001
  • Throughout this paper, I adjusted the study of 'Qian Yi'(錢乙)'s Medical Thought, and the following is the summary. 1. 'Qian Yi' wrote 'Xiao Er Yao Zheng Zhi Jue'("小兒藥證直訣", edited by 誾季忠), and there were 'Shang Han Lun Zhi Wei'("傷寒論指微"), 'Ying Ru Lun', however those are loss of the record. 2. Qian Yi's 'Zhi Jue'("直訣") was influenced by 'Lu Xin Jing', yet if we compare the quality of 'Sheng Li, Byeng Li, Bang Jae'(生理, 病理, 方劑), 'Lu Xin Jing' cannot be the foundation of 'Zhi Jue'. He took over 'Nei Jing, Shang Han Lun, Jin Gui Yao Lue, Shen Long Ben Cao Jing, Tai Ping Sheng Hui Fang'("內經", "傷寒論", "金?要略", "神膿本草經", "太平聖惠方") and put them together to the direct clinical experiences of pediatrics. 3. There is no reference regarding the difficulties of pediatric diagnosis and diseases in 'Huang Di Nei Jing'("黃帝內經") Before 'Bei Song'(北宋), regardless of the lack of data related to pediatric diseases, 'Qian Yi' established the pediatric system in 'Xiao Er Yao Zheng Zhi Jue' for the first time. 4. In his diagnosis of the pediatric diseases, he 'Si Zhen He Can'(四診合參), also considered in the eye exam seriously. In addition, he closely combined 'Wu Zang Bian Zheng'(五臟辨證), and diagnosis the pediatric diseases. 5. 'Wu Zang Bian Zheng', what Qian established method was based on 'Zheng Ti Guan'(整體觀) in 'Huang Di Nei Jing'. It was based on clinical experiences and established the perspectives of 'Tian Ren Xiang Ying'(天人相應). First of all, he pinpointed 'Zhu Zheng'(主證) clearly. Secondly, he pinpointed the relationships to symptoms and then, he distinguished a generic character of 'Xu, Shi, Han, Re'(虛, 實, 寒, 熱). Finally, he made an induction from genealogical pediatric physiology. 6. 'Qian Yi' took a serious view of 'Ban Zhen'(斑疹), the inadequate field in those days. At that time, he criticized on the habituation of the misuse of medication. He treated separately which 'Ji Jing'(急驚) as 'Liang Xie'(凉瀉) and 'Man Jing'(慢驚) as 'Wen Bu'(溫補). He proposed 'Cong Gan Zhu Feng, Xin Zhu Jing'(從肝主風, 心主驚) theory and formulated 'Jing Feng'(驚風) theory as well. 7. As an opponent of a tendency to misusage of medicine, 'Qian Yi' made out a prescription with pliant medicine. He emphasized on the treatment to 'Gong Bu Shang Zheng, Bu Bu Zhi Xie, Xiao Bu Jian Shi'(攻不傷正, 補不滯邪, 消補兼施) because he had so lucid demonstration to 'Xu Shi Han Re'(虛實寒熱) of the five viscera in the field of 'Bang Yak'(方藥). 8. There were no pediatrics schools at that time, however, the pediatrics was being made up gradually by 'Jin Yuan Si Da Jia'(金元四大家) who was influenced by 'Qian Yi'. He raised an objection to medical treatment using pliant medicine. 'Qian Yi' applied 'Qu Xia'(驅下) treatment using 'Han Liang'(寒凉) medicine. 'Han Liang Pai'(寒凉派) is greatly influenced by Qian. 'Chen Wen Zhong'(陳文中) had a great impact on 'Han Liang Pai' who used a 'Zao Shu Wen Bu'(燥熟溫補) medicine for treatment. Since 'Song Jin'(宋金), he had a tremendous influence on pediatrics treating patients in both 'Han Wen'(寒溫) ways. 9. 'Qian Yi' had an influence on his medical thoughts on future generations, especially to 'Wan Quan'(萬全) of 'Ming Dai', 'Wu Tang'(吳塘) of 'Qing Dai'(淸代) and 'Yun Shu Jie'(?樹珏) of 'Min Guo'(民國). 'Wan Quan' is an advocate of 'You Yu, Bu Zu Zhi Shuo'(有餘, 不足之說)of 'Xiao Er Wu Zang'(小兒五臟) that he revealed Qian's 'Wu Zang Bian Zheng'(五臟辨證). 'Wu Tang' disclosed Qian's 'Xiao Er Ti Zhi Shuo'(小兒體質說) and 'Xiao Er Ke'(小兒科)'s 'Yong Yao Lun'(用藥論), therefore, he uncovered pediatric physiological characteristics through the advocate of Qian's 'Zang Fu Rou Ruo, Ji Gu Nen Qie, Yi Xu Yi Shi, Yi Han Yi Re' (臟腑柔弱, 肌骨嫩怯, 易虛易實, 易寒易熱). 'Yun Shu Jie' developed intrinsic relationships among time, symptom and 'Tian Ren Xiang Ying Guan'(天人相應觀), What 'Qian Yi' stated about them. And also, he developed Qian's 'Di Huang Wan'(地黃丸), 'Xie Qing Wan'(瀉靑丸), 'Yi Huang San'(益黃散) clinical usages as well. 10. Regarding Qian's 'Wu Zang Xu Shi'(五臟虛實), it has an influence on 'Zhang Yuan Su'(張元素)'s 'Zang Fu Bing Ji Bian Zheng'(臟腑病機辨證). 'Di Huang Wan', 'Xie Qing Wan', 'Xie Xin Tang'(瀉心湯), 'Yi Huang San', 'Xie Huang San'(瀉黃散) are the standard prescription of 'Wu Zang Bu Xie'(五臟補瀉). It is under the influence of Qian's treatment. Besides, 'Qian Yi' took a serious view of 'Xiao Er'(小兒)'s 'Pi Wei'(脾胃). 'Qian Yi' had an impact on 'Li Dong Yuan'(李東垣) one of the member of 'Bu Tu Pai'(補土派). 'Di Huang Wan', which placed great importance on 'Bu Yi Shen Yin'(補益腎陰), had a great impact on 'Da Bu Yin Wan'(大補陰丸) and 'Jin Yuan Si Da Jia' as well. 11. In a theory of Qian's 'Wu Zang Bian Zheng', though it had been stated clearly in 'Wu Zang Bian Zheng', but he neglected in 'Liu Fu Bian Zheng'(六腑辨證). In prescription field, The problem with the medicine is that it is either toxic or mineral, therefore, we are not able to use those medicine in a clinical testing at the present time.

  • PDF

Adoption and Efficacy of ISO 15189 in Medical Laboratories for Diagnostic and Research (메디컬시험기관에서 ISO 15189 도입의 필요성과 시행의 효용성)

  • Yang, Man-Gil;Lee, Won Ho;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.158-167
    • /
    • 2016
  • The requirements for medical laboratories ISO 15189 is examined in organization and a quality management system, stressing the importance of evidence, document control, and control of records and clinical material. Medical services are provided from the areas of resource management, and pre-examination, examination and post-examination processes. The main goal of ISO 15189 accreditation is to improve the quality of laboratory services provided for patients and clinical users not only through compliance with consensually developed and harmonized requirements but also by adopting the philosophy of continual improvement using the Plan-Do-Check-Act cycle. Laboratory quality should be evaluated and improved in all steps of the testing process as the state-of-the art indicates that the pre- and post-analytical phases are more vulnerable to errors than the intra-analytical phase. The Korea Laboratory Accreditation Scheme (KOLAS), a national accreditation body, provides medical laboratory accreditations for appropriate approaches to evaluating the competence of a medical laboratory in providing effective services to its customers and clinical users. Adoption of ISO 15189 in 2010s as a government policy has been delayed, and only 5 laboratories have been accredited to date in Korea. The medical laboratories should seek the adoption of ISO 15189 with a positive attitude for quality improvement and strengthening of international competitiveness.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF