• Title/Summary/Keyword: testing and calibration

Search Result 241, Processing Time 0.034 seconds

Verification of the large scale, free-free resonant testing equipment using Jumunjin sand (주문진 표준사를 이용한 대형 공진주 시험 장비의 검증)

  • Park, In-Beom;Park, Chul-Soo;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1415-1424
    • /
    • 2009
  • Measuring dynamic properties of gravel-sized materials demands large specimens. Due to the difficulties in experiment as well as equipment, the dynamic properties of gravel-sized material has rarely been investigated. To realize free-free end condition more properly and stabilize specimen during testing with new specimen support system, a free-free resonant column testing device, which is capable of testing gravel-sized materials and constraining a specimen in free-free boundaries, is developed. We report the calibration of the equipment and preliminary testing results on Jumunjin sand. The testing data are compared with the previous data obtained from the existing fixed-free resonant column test.

  • PDF

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

Bayesian One-Sided Hypothesis Testing for Shape Parameter in Inverse Gaussian Distribution

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.3
    • /
    • pp.995-1006
    • /
    • 2008
  • This article deals with the one-sided hypothesis testing problem in inverse Gaussian distribution. We propose Bayesian hypothesis testing procedures for the one-sided hypotheses of the shape parameter under the noninformative prior. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian hypothesis testing procedures based on the fractional Bayes factor, the median intrinsic Bayes factor and the encompassing intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

  • PDF

A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography (적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Pack, Chan-Joo;Kim, Dong-Soo;Jung, Duk-Woon;Chang, Ho-Sub
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.421-426
    • /
    • 2009
  • The emissivity is different because the emitted angle changes according to the position of the infrared thermography camera and object. Because of this, the temperature distribution expressed when measuring the temperature by using the infrared thermography system is not the accuracy temperature. Although the real surface temperature is constant, the temperature measured by using infrared thermography camera have error in accordance with the value of emissivity. In this paper, the temperatures of the round cylindrical object and the flat square object that heated to the equal temperature were measured by infrared thermography camera. The emissivity calibration formula and correction table are made with the affect of the view angle and emission angle form the surface temperature value. The error of measured temperature values are corrected by using the emissivity calibration formula and correction table, and apply to defect detection of the nuclear power plant pipe. From the calibration method, reliability surface temperature values were obtained.

Application and testing of a triple bubbler sensor in molten salts

  • Williams, A.N.;Shigrekar, A.;Galbreth, G.G.;Sanders, J.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1452-1461
    • /
    • 2020
  • A triple bubbler sensor was tested in LiCl-KCl molten salt from 450 to 525 ℃ in a transparent furnace to validate thermal-expansion corrections and provide additional molten salt data sets for calibration and validation of the sensor. In addition to these tests, a model was identified and further developed to accurately determine the density, surface tension, and depth from the measured bubble pressures. A unique feature of the model is that calibration constants can be estimated using independent depth measurements, which allow calibration and validation of the sensor in an electrorefiner where the salt density and surface tension are largely unknown. This model and approach were tested using the current and previous triple bubbler data sets, and results indicate that accuracies are as high as 0.03%, 4.6%, and 0.15% for density, surface tension, and depth, respectively.

A Case Study of Quality Assurance and Control for the Soil Environmental Assessment in Abandoned Mine (광산지역 토양정밀조사 정도관리(QA/QC) 사례 연구)

  • Ji, Won Hyun;Kim, Jong Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • A testing inspection is one of the important in the industry, owing to determine the reliability and directivity of testing inspection results. Therefore, the quality assurance and quality control (QA/QC) work which performed by personnel not directly in the inventory compilation development, in testing inspection must be thoroughly considered. Some agencies for environmental test inspection, they sometimes misunderstood that the QA/QC was ended with proficiency testing performance and on-site assessment by a director. Thus, results were often calculated without QA/QC work by self manual when conducting test. The objective of this study was to improve reliability of testing and inspection agency through the QA/QC case study which basically performed to raising reliability of testing and inspection agency. In this study, it increased reliability of result by verifying calibration curve (IC, ICV, CCV), blank, accuracy (LCS, MS) and precision as QA/QC performance, while performing investigation of soil contamination in mining areas. This study suggests that reliability establishing method of test result and management method of analysis process, through the QA/QC instance of testing agency.

SPACE-BORNE MICROWAVE RADIOMETER CALIBRATION/VALIDATION IN CHINA

  • Zhenzhan, Wang;Yun, Li;Shixiang, Tan
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.598-603
    • /
    • 2002
  • We summarize the activities concerning to the space-borne microwave radiometer (RAD) calibration and validation (Cal/Val) in China. It is important to know in advance the brightness temperature of a given sea surface before external calibrating RAD due to its special characteristic of system. In the paper, we analyse some modeling results on sea surface emissivity and atmospheric transmissivity at different frequencies, and compare the calculated brightness temperatures with those measurements from some air-borne microwave radiometers. We also introduced the whole contents on RAD Val and developed two methods of retrieving sea surface winds. We compared the retrievals of wind speeds to those from NDBC buoys. At last, we introduce some plans of Cal/Val for testing our RAD.

  • PDF

A Study of the Fuel Economy Improvement of a Heavy Duty in Commercial Vehicle(I) (상용차 탑재 대형엔진의 차량연비 개선 연구(I))

  • Lyu, Myung-Seok;Doo, Byung-Mann;Ku, Young-Gon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.44-48
    • /
    • 2008
  • This paper describes on studies of the heavy duty engine calibration for better fuel economy based on real driving conditions. Using testbed validated software simulation of the engine and turbocharger system, an alternative turbocharger specification, with potential to improve fuel economy was identified. Secondly, the engine calibration was modified to optimize vehicle fuel economy over a typical customer drive cycle whilst still meeting the steady-state (testbed) emissions legislation. These results were confirmed by field testing of a vehicle equipped with the updated specifications. This study found good agreements between the prediction and the field test on the vehicle fuel economy improvements of the express bus with updated calibration and turbocharger.

Measurement Uncertainty of Vibration Testing Result with Including Uncertainty of Testing Facilities (시험장비의 특성을 고려한 진동시험결과에 대한 측정불확도 추정)

  • Moon, Seok-Jun;Chung, Jung-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.781-786
    • /
    • 2016
  • All measurements are subject to uncertainty and a measurement result is complete only when it is accompanied by a statement of the associated uncertainty. By international agreement, this uncertainty has a probabilistic basis and reflects incomplete knowledge of the quantity value. The "Guide to the Expression of Uncertainty in Measurement", commonly known as the GUM, is the definitive document on this subject. The requirements for estimation of measurement uncertainty apply to all results provided by calibration laboratories and results produced by testing laboratories under the optional circumstances. In this paper, a procedure for estimation of measurement uncertainty from vibration testing is proposed on KS F 2868:2003 as an example. Both Type A and Type B evaluation of uncertainty are considered to calculate the combined standard uncertainty and expanded uncertainty.