• Title/Summary/Keyword: testing and calibration

Search Result 241, Processing Time 0.025 seconds

A Pulse-Echo Testing Model for Partially Damaged Ultrasonic Transducers (부분 손상을 입은 초음파 탐촉자의 펄스-에코 시험 모델)

  • Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.2
    • /
    • pp.95-108
    • /
    • 1996
  • In ultrasonic testing, flaw signal from which quantitative information on flaws is determined is influenced by 3 factors : (1) the incident wavefield.produced by the transducer, (2) the scattered waves produced by flaws, and (3) the reception of the scattered waves back at the transducer. So even small changes in transducer performance due to aging or unexpected damages can produce the changes in the characteristics of flaw signal and finally the changes in the quantitative information on flaws. Thus a reliable calibration method of transducer performance is desired. Recently, theoretical models for ultrasonic testing have been employed as reference standards for the calibration of transducers which are considered as circular planar piston sources in the most of cases. But this simplification cannot be applied to partially damaged transducer which has lost their symmetry in performance, even not in appearance. Unfortunately there has been no reliable practical model which can be used for the calibration of partially damaged transducers. Here a pulse-echo testing model for partially damaged ultrasonic transducers was developed with experimental verification. The experimental responses agree very well with the theoretical prediction. So we expect that this model can be served as a theoretical reference standards for transducer calibration.

  • PDF

Development and deployment of large scale wireless sensor network on a long-span bridge

  • Pakzad, Shamim N.
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.525-543
    • /
    • 2010
  • Testing and validation processes are critical tasks in developing a new hardware platform based on a new technology. This paper describes a series of experiments to evaluate the performance of a newly developed MEMS-based wireless sensor node as part of a wireless sensor network (WSN). The sensor node consists of a sensor board with four accelerometers, a thermometer and filtering and digitization units, and a MICAz mote for control, local computation and communication. The experiments include calibration and linearity tests for all sensor channels on the sensor boards, dynamic range tests to evaluate their performance when subjected to varying excitation, noise characteristic tests to quantify the noise floor of the sensor board, and temperature tests to study the behavior of the sensors under changing temperature profiles. The paper also describes a large-scale deployment of the WSN on a long-span suspension bridge, which lasted over three months and continuously collected ambient vibration and temperature data on the bridge. Statistical modal properties of a bridge tower are presented and compared with similar estimates from a previous deployment of sensors on the bridge and finite element models.

Precise Baseline Measurement and Computation of Correction Factor For EDM Instrument Calibration (EDM 장비의 검교정을 위한 정밀 기선장 관측 및 보정계수 산정)

  • 조재명;윤홍식;이원춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.83-89
    • /
    • 2004
  • The electronic distance measurement instrument, first introduced in the 1950s has, since those early days, undergone continual refinement. Rapid advances in related technologies have provided lighter, smaller and more precise equipment. Understanding for the principle, the standardized observation technique and the precision of EDM instrument is mostly important to improve the quality and the reliability of by-product in the field of engineering and industrial surveying. Simple and accurate calibration is regularly and periodically necessary to maintenance the precision of EDM instrument. This paper describes the calculated example of zero error and scale error as a correction of EDM by applying the least square method to baseline observations. Here we deals also with the testing criteria for precision instrument testing according to different types of EDM instruments.

  • PDF

THE JAPANSE STATUS OF LABORATORY ACCREDITATION BASED ON FASTENER QUALITY ACT.

  • Aoyagi Tutomu;Imai O Yoshio
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.339-344
    • /
    • 1998
  • Since 1997, JAB (The Japan Accreditation Board for Conformity Assessment) had started the activity of accreditation for the laboratory based on U.S. PL101-592: the Fastener Quality Act that was signed by President Bush on 1990. The number of accredit laboratories are 69 in Japan, 21 in Taiwan, 2 in Korea and 189 in U. S. A, as of 09/10/1998. The JAB accreditation encompasses the requirements of the ISO/IEC Guide 25, and the relevant requirements of ISO 9002. The purpose of ISO/IEC Guide 25, also had been harmonized as JIS Z 9325 'General requirements for the competence of calibration and testing laboratories 'mainly facilitates and promotes acceptance of calibration and test results between countries to avoid barriers to trade through as 'one stop testing'. The features and differences between Guide 25 and ISO 9000 will be clarify in this report.

  • PDF

Measurements of Sub- and Super Harmonic Waves at the Interfaces of Fatigue-Cracked CT Specimen

  • Jeong, Hyun-Jo;Barnard, Dan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Nonlinear harmonic waves generated at cracked interfaces are investigated both experimentally and theoretically. A compact tension specimen is fabricated and the amplitude of transmitted wave is analyzed as a function of position along the fatigued crack surface. In order to measure as many nonlinear harmonic components as possible a broadband Lithium Niobate ($LiNbO_3$) transducers are employed together with a calibration technique for making absolute amplitude measurements with fluid-coupled receiving transducers. Cracked interfaces are shown to generate high acoustic nonlinearities which are manifested as harmonies in the power spectrum of the received signal. The first subharmonic (f/2) and the second harmonic (2f) waves are found to be dominant nonlinear components for an incident toneburst signal of frequency f. To explain the observed nonlinear behavior a partially closed crack is modeled by planar half interfaces that can account for crack parameters such as crack opening displacement and crack surface conditions. The simulation results show reasonable agreements with the experimental results.

The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer (유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구)

  • Joo, Sung-Kyun;Kim, Joon;cheong, Nam-Yong;Lim, Kyu-Chual;Choi, Young-Hwan;Kim, Sang-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 $\sim$ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.

Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument (방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Lee, Yun-Hee;Kim, Ho-Dong;Jung, Ki-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.246-254
    • /
    • 2006
  • A computation program has been developed for automatic data processing in the calibration process of gamma survey meter. The automatic processing program has been developed based on Visual Basic. The program has been coded according to steps of calibration procedure. The OLE(object linking an embedding) Excel automation method fur automatic data processing is used in this program, which is a kind of programming technique for the Excel control. The performance test on the basis of reference data has been carried out by using the developed program. In the results of performance test, the values of calibration factors and uncertainties by the developed program were equal to those obtained from the reference data. In addition, It was revealed that the efficiency and precision of working are significantly increased by using the developed program.

Wind Analysis and Site Assessment for Test Site of 3MW Wind Power System (3MW 풍력발전시스템 개발품의 육상풍력실증단지 조성 타당성 평가를 위한 풍황 및 지형평가 연구)

  • Woo, Sangwoo;Lee, Ki-Hak;Lee, Sang-Il;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.35.2-35.2
    • /
    • 2011
  • A wind turbine power performance test is very important to wind turbine manufacturers because a wind farm developer or planner must want to define power performance characteristics and reliability of new wind turbines. Based on the IEC 61400-12-1, A wind turbine test site has to be nicely installed at flat terrain for testing. We are developing the wind power system which is IEC wind class IIa model with rated power of 3MW. KEPCO's Gochang power testing center was considered as candidates to build the test site without site calibration. This paper aims to verify the validity of the test site by using implement site assessment result that was based on IEC 61400-12-1.

  • PDF

A Study on Operational Software Development and Calibration of Multi-Axis Vibration Testing Device (다축 제어용 가진기의 구동소프트웨어 개발 및 보정에 관한 연구)

  • 정상화;김재열;류신호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in todey's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, Multi-axis durability testing device is used to carry out the fatigue test. In this paper, The operation software for simultaneously driving Multi-axis vibration testing device is developed and the input and output data are displayed in windows of PC controller with real time. Moteover the characteristics of the displacement and the load of Multi-axis actuators are calibrated separately.

  • PDF