• Title/Summary/Keyword: tested result

Search Result 4,507, Processing Time 0.032 seconds

A Study on Power System Voltage Stability Analysis by the Direct Lyapunov Function (Luapunov 직접법에 의한 전력계통 전압안정도 해석)

  • 문영현;박능수;이태식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.693-702
    • /
    • 1994
  • This paper deals with direct voltage stability analysis using a power system energy function. The structure preserved energy function is proposed as an energy function for voltage stability analysis. With the use of the proposed energy function voltage collapse conditions are derived, which yields the exactly same results with the Jacobian matrix approach. The voltage collapse phenomenon is analyzed by several methods, which shows that all of the methods produce the same voltage condition. This study also investigates the voltage collapse dynamics by using the proposed energy function. As a result, it has been found that the voltage collapse can be classified into two categories: static and dynamic instablilties which have quite different behaviors. In addition a new method is presented to calculate the power capacity limit of transmission lines with respect to voltage stability. The proposed method is tested for a 2-bus sample system, which shows the characteristics of voltage collapse phenomenon via the energy function.

The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide (선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구)

  • 정종한;김문환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

Current Distribution and Numerical Analysis of AC Losses on Multi-Layer HTS Cable (다층 고온 초전도 케이블의 전류 분포 및 교류손실 해석)

  • 김영석;이병성;장현만;곽민환;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.452-455
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$_{c}$ superconductors (HTS). A prototype HTS cable have been constructed multi-layer cable using Bi-2223 tape and tested. The AC transport losses under self field were investigated at 77K on the 19 filamentary tape and multi-layer HTS cables. And we carried out numerical analysis using bean model. The result shows that the total transport current of HTS cable in L$N_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to I$^2$ and higher than losses of inner layer. In case of Ip=Ic, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer. As magnetic distribution was concentrated on outer layer.r.

  • PDF

Analysis of Estimation Errors in Rotor Position for a Sensorless Control System Using a PMSM

  • Park, Yong-Soon;Sul, Seung-Ki;Ji, Jun-Keun;Park, Young-Jae
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.748-757
    • /
    • 2012
  • In a sensorless control system with a Permanent Magnet Synchronous Motor (PMSM), the angular position of the rotor flux can be estimated by a voltage equation. However, the estimated angle may be inaccurate due to various causes. In this paper, it was comprehensively analyzed how various causes affect the angle error. As a result of the analysis, an error equation intuitively describing these relationships was derived. The parameter errors of a PMSM and the non-ideal properties of the driving system were identified as error-causing factors. To demonstrate the validity of the error equation, PMSMs were tested at various operating points. The variations in angle errors could be well explained with the error equation.

A Reduced Component count Single-stage Electrolytic Capacitor-less Interleaved Totem-pole On-board Battery Charger (적은 소자수를 갖고 전해커패시터가 없는 단일단 인터리브드 토템폴 전기자동차 탑재형 충전기)

  • Kim, Byeong-Woo;Cho, Woo-Sik;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.510-516
    • /
    • 2017
  • This paper proposes a single-stage interleaved totem-pole on-board battery charger with a simple structure and a reduced component count. Apart from achieving ZVS turn-on of all switches and ZCS turn-off of all diodes, this charger does not require an input filter due to its CCM operation and bulky electrolytic capacitors, which in turn result in a high power density. A single-stage power conversion technique is applied to the interleaved structure in order to achieve a high power density and high efficiency. A 2.5 kW prototype of the proposed charger is also built and tested to validate the proposed operation.

Consecutive Vowel Segmentation of Korean Speech Signal using Phonetic-Acoustic Transition Pattern (음소 음향학적 변화 패턴을 이용한 한국어 음성신호의 연속 모음 분할)

  • Park, Chang-Mok;Wang, Gi-Nam
    • Annual Conference of KIPS
    • /
    • 2001.10a
    • /
    • pp.801-804
    • /
    • 2001
  • This article is concerned with automatic segmentation of two adjacent vowels for speech signals. All kinds of transition case of adjacent vowels can be characterized by spectrogram. Firstly the voiced-speech is extracted by the histogram analysis of vowel indicator which consists of wavelet low pass components. Secondly given phonetic transcription and transition pattern spectrogram, the voiced-speech portion which has consecutive vowels automatically segmented by the template matching. The cross-correlation function is adapted as a template matching method and the modified correlation coefficient is calculated for all frames. The largest value on the modified correlation coefficient series indicates the boundary of two consecutive vowel sounds. The experiment is performed for 154 vowel transition sets. The 154 spectrogram templates are gathered from 154 words(PRW Speech DB) and the 161 test words(PBW Speech DB) which are uttered by 5 speakers were tested. The experimental result shows the validity of the method.

  • PDF

A Study on Battery Simulator Including Aging and Dynamic Impedance Model (노화 및 동특성 임피던스 모델을 포함한 배터리 시뮬레이터에 관한 연구)

  • Lee, Jong-Hak;Kim, Soo-Bin;Oh, Sang-Keun;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.171-180
    • /
    • 2020
  • This paper presents the implementation and control methods of a battery simulator. The proposed battery simulator can emulate the dynamic characteristics of any actual battery using the second RC ladder model of the equivalent circuit. Moreover, it can emulate the variation of impedance, which is the result of the change of battery characteristics due to the aging effect. The parameters of the battery simulator can be derived from the sequence of tests of the actual battery or only from the data supplied by the battery manufacturer. Proposed methods for the battery simulator are tested by extensive experiments. Test results show that the proposed battery simulator can emulate not only the dynamic characteristics but also the aging effects of the actual battery in real time.

An Experimental Study on Flexural and Shear Strength of Reinforced Concrete Beam Using Reinforcing Materials (보강재를 사용한 철근콘크리트 보의 휨·전단내력에 관한 실험적연구)

  • Hong, Sang-Kyun;Eun, Hee-Chang;Park, Ki-Choul;Chung, Heon-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.65-73
    • /
    • 1997
  • In this paper, It is the effect of using fiber sheet (Carbon Fiber Sheet & Aramid Fiber Sheet) and Steel Plate for reinforced concrete beam. 25 specimens are tested, 16 specimens are for bending capacity and the other are for shear capacity. In the case of bending testing, the kind and quantity of the reinforcement materials, the bondage and the existence of crack were selected as experimental variables. In the case of shear testing, It is testified the effect of reinforcement with the variables of the method of reinforcement (side type and U type). As a result, Using the reinforcing materials can increase the capacity of bending and shear stress.

  • PDF

A Study on the Characteristics of Corona Critical Voltage on Increasing Load Impedance (전극길이 및 펄스반복율에 대한 부하임피던스 특성변화에 관한 연구)

  • Joung, Jong-Han;Song, Woo-Jung;Jeon, Jin-An;Lee, U-Soo;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.184-186
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

A Phase-Domain Equivalent Representation for Electromagnetic Transients Studies (전력계통 과도현상 해석을 위한 상영역에서의 등가축약 기법)

  • Jung, B.T.;Kim, S.H.;Heo, S.I.;Ahn, B.S.;Hong, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.731-733
    • /
    • 1996
  • In this paper, a new time-domain reduction method for unbalanced 3 phase power systems will be represented. The impulse response of the system is used to identify a discrete-time equivalent filter model. The model is formulated directly in the phase domain. Each phase has a self-mode equivalent model and two mutual-mode equivalent models. The equivalent model is determined by the transfer function identification technique based on the Prony analysis. The model is implemented in EMTDC and tested with an unbalanced 3 phase network. The result of test showed that the equivalent model is accurate.

  • PDF