• 제목/요약/키워드: test standard

Search Result 8,501, Processing Time 0.044 seconds

Research on Relations Between Intermittent Suspension Treatments of irrigation at Different Growing Stages and yields of Paddy Rice (논벼의 생육시기별 간단단수처리와 수확량과의 관계에 관한 연구)

  • 이기춘
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3795-3814
    • /
    • 1975
  • The purpoes of this thesis is to study the effect of the variation of the beginning date of the suspension of irrigation and the length of intermittent suspension period of irrigation in the paddy field on the growth and yield of rice, so as the provide a critical limit of saving irrigation water and an irrigation method to prevent drough damage in rice cultivation. In this experiment, the rice variety adopted was NONGRIM No.29. There were seven main test plot, each test plot having a different beginning date of the suspension of irrigation. A main test plot was susdivided into five small test plots, each having a different length of the suspension period of irrigation. The results obtained in this experiment are summarized as follows: 1. The number of tillers is controlled by the treatment of the suspension of irrigation, its beginning date being early of late. The reductive effects of beginning dates of suspension upon the number of tillers. investigated on July 30, are about 84% for the treatment suspended on July 8, 87% on July 12, and 92% on July 19, respectively, in comparison with the standard plot. However. the suspenion treatments after the foregoing dates does not affect the control of their numbers. On the other hand, the lengths of intermittent suspension periods influence highly on the number of tillers to be restrained considerably, the decrease ratio ranging from 91% to 80% Both treatments on dates and periods are so intermingled that the restraining effects of suspension periods become greater as the dates of its beginning are earlier. 2. The elongation of plant hieghts also restrained considerably by the longer periods and earlier dates of suspension treatments of irrigation. Especially, the effects of the lengths of suspension periods become more serious. 3. Heading dates are delayed by two to five days through the suspension treatments of irrigation. However, the heading stage ends almost on the same day without relation to the differences between the irrigation suspension treatments. In the test plot where the suspension date of irrigation comes after the young panicle forming stage, the heading stage ends one or two days later than in the standard test plot. 4. Both culm lengths and panicle lengths show significant differences in their values, i.e., their lengths are shorter, as the begining dates of irrigation suspension are earlier and the suspension periods are longer. 5. The earlier the beginning date and the longer the period of irrigation suspension, the less is the number of panicles per hill in comparison with the standard plot. 6. The earlier the beginning date and the longer the period of irrigation suspension, the higher is the significant difference in the number of kernels per panicle in comparison with that in the standard test plot, i.e., the less is the number of kernels per panicle. 7. The earlier the beginning date and the longer the period of irrigation suspension, the lighter are the weights of rough rice and straws per hill in comparison with those in the standard plot.

  • PDF

A Study on the proficiency test of pH measurements (pH 측정의 숙련도 시험에 대한 연구)

  • Lee, Hwashim;Kim, Myungsoo;Choi, Jongoh
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.230-237
    • /
    • 2001
  • In general, the pH measurement follows calibration of glass electrode system using pH standard solution. When pH is measured at constant temperature, uncertainty factors are mainly related to the accuracy of pH standard solution and the accuracy and precision of glass electrode. Participants in this proficiency test were the volunteers trying to know the distribution of the measured pH values for the same sample and the sources of error through 1998 and 1999. The samples for proficiency test are phosphate salt standard solutions specially prepared in KRISS, of which pH values were 6.860, 7.415(at $25^{\circ}C$), and the stability test was performed for the same periods of proficiency test. The results of the proficiency test were plotted according to Youden plot, which shows whether the error is random or systematic. The results of Youden plot showed that the source of error was from the systematic effect of laboratories in each year. This shows that the source of error is the standard solutions used in laboratories.

  • PDF

Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function (확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가)

  • Choi J.H.;Park J.S.;Seok C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1691-1694
    • /
    • 2005
  • The fatigue characteristic of a material or a structure is derived from fatigue tests of standard specimens. However test results of standard specimens are very different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristic of a real waterwork pipe by conducting fatigue tests with standard specimens and non-standard(plate-shaped) specimens of base metal and weld metal. Also, to evaluate fatigue characteristic based on life distribution, statistical fatigue characteristic was analyzed by the normal distribution and related data of P-S-N curve.

  • PDF

Development of a Large Force Standard Machine with Built-in Force Transducers (내장형 힘 변환기를 이용한 대용량 힘 표준기 개발)

  • Gang, Dae-Im;Lee, Jeong-Tae;Song, Hu-Geun;Kim, Eom-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.667-675
    • /
    • 2000
  • Force measuring devices should be calibrated to guarantee their test results. In order to establish the force standards in Korea, deadweight machines of 5 kN, 20 kN, 100 kN and 500 kN capacity and a hydraulic force standard machine of 2 MN capacity were installed at the Korea Research Institute of Standards and Science(KRISS). As heavy industries in Korea have been developed, we should measure large forces over 2 MN capacity precisely in industries. We developed a 10 MN force standard machine with built-in force transducers which is more compact and cheaper than hydraulic force standard machines which have been widely used as large force standards in most national metrology laboratories. Test results reveal that the relative expanded uncertainty of the force machine is less than 4.1 $\times$ 10-4 in the range of 1 MN-4.5 MN.

Efficiency Review for the Evaluation Method and standard for High speed Railway Rail Fastening System (고속철도 레일 체결장치 성능 평가방법 및 기준검토)

  • Kim In-Jae;Kang Kee-Dong;Han Sang-Chul;Yang Shin-Choo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.818-823
    • /
    • 2004
  • In case of the Korea Railroad, when we would decide the track structure, it has been introduced the whole track structure system based on only the foreign application cases and data offered by manufacturers without the process of the objective performance verification. The value of property for track materials, derived from the calculation of track structure, was hard to perform the objective performance evaluation among track structure systems because each manufacturer adopted the different test method and standard. To solve the above-mentioned problem, it should suggest the technical and objective evaluation method about the performance of track materials and meet with the standard of High Speed railroad and international railroad through the establishment and revision of performance standard. In the objective and technical respects, it will be a major role to decide the track structure. In this paper, I would like to summarize the case which was improved the problem of test method and standard exposed from the performance verification of Rail Fastening System among the track structure systems of High speed railroad.

  • PDF

The Status of Blood and Body Fluid Exposure and Affecting Factors among Nursing Students including Knowledge, Performance regarding Standard Precautions (간호대학생의 임상실습중 혈액 및 체액 노출현황과 영향 요인 - 감염관리 지식 및 수행도 중심으로-)

  • Kim, Hee-Jung;Kim, Nam-Cho
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.17-30
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the status of exposure to blood and body fluid and factors affecting on blood and body fluid exposure of nursing students including knowledge, performance regarding standard precautions. Methods: 280 nursing students in D-city and S-city participated in this study. Data collection was conducted from January to March 2012. Students' knowledge and performance on standard precautions of infection control in hospitals were measured using the measurement developed by Hong(2010). Data analysis was performed using descriptive statistics, t-test, one way-ANOVA, ${\chi}^2-test$, Pearson correlation coeficient, logistic regression by the SPSS WIN 18.0 program. Results: 58.6 percent of subjects experienced a exposure to blood and body fluid. The level of nursing students' knowledge level regarding standard precautions was $22.44{\pm}2.11$ and performance level was $4.31{\pm}0.50$. The factors affecting on blood and body fluid exposure of nursing students were knowledge level and education type about infection control. Conclusions: Based on the findings of this study, to decrease the exposure to blood and body fluid of nursing students, a proper education need to be stressed to improve nursing students' infection control knowledge and awareness.

  • PDF

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

An Empirical Evaluation of Test Data Generation Techniques

  • Han, Seung-Hee;Kwon, Yong-Rae
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.274-300
    • /
    • 2008
  • Software testing cost can be reduced if the process of testing is automated. However, the test data generation task is still performed mostly by hand although numerous theoretical works have been proposed to automate the process of generating test data and even commercial test data generators appeared on the market. Despite prolific research reports, few attempts have been made to evaluate and characterize those techniques. Therefore, a lot of works have been proposed to automate the process of generating test data. However, there is no overall evaluation and comparison of these techniques. Evaluation and comparison of existing techniques are useful for choosing appropriate approaches for particular applications, and also provide insights into the strengths and weaknesses of current methods. This paper conducts experiments on four representative test data generation techniques and discusses the experimental results. The results of the experiments show that the genetic algorithm (GA)-based test data generation performs the best. However, there are still some weaknesses in the GA-based method. Therefore, we modify the standard GA-based method to cope with these weaknesses. The experiments are carried out to compare the standard GA-based method and two modified versions of the GA-based method.

A Study on the Standard Establishment of Test-Bed Master Plan for Successful Realizations of U-City (U-City의 성공적 구현을 위한 테스트베드 기본계획의 기준 수립에 관한 연구)

  • Lee, Jae-Yong;Pi, Min-Hee;Jung, Ju-Young;Shin, Dong-Bin
    • Spatial Information Research
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Even after many constructions of test-beds to verify R&D results, there is no standard to set up a consistent and systematic test-bed master plan. Therefore, this research derives standards of a u-city test-bed master plan. To verify these standards, the research constructs the potential U-City master plan targeting Cheongna district in Incheon. Standards of a test-bed master plan which is suggested by this research will bring strengths to construct a test-bed such as clear construction procedures from presenting directions of planning, saving cost, effective management of equipments, and so on.

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.