• Title/Summary/Keyword: test standard

Search Result 8,477, Processing Time 0.036 seconds

Comparison and Analysis between the simulation and test result for Quality Assessment of Surge Protective Insulating Transformer. (서지방호용 절연변압기 성능시험관련 모의해석 및 시험결과와의 비교분석)

  • Choi Young-Ha;Kim Myung-Young;Lee Kang-Won;Ohn Jung-Ghun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.519-522
    • /
    • 2003
  • 'KRS 6330-3256라' standard regulates performance test of insulating transformer for protecting the electronic interlock linkage equipment which is being done by test procedures and methods according to the standard. The balance/unbalance test evaluating the performance of transformer are applied by impulse voltage($l2/200{\mu}s$) but affected by many other factors. Therefore, the review about these is necessary to have the reliability and reappearance of test results. In this paper, we have simulated about several phenomenon appearing in real balance/unbalance test and compared simulated results with real ones. With the basis of these results, the influence to test result of inner and outer factors are investigated and analyzed and established the plan boosting the reliability and reappearance of test results.

  • PDF

Application of the Ecotoxicological Standard Method using Population Growth Inhibition of Marine Phytoplankton (식물플랑크톤의 개체군성장저해율을 이용한 해양생태독성 시험방법에 관한 연구)

  • Lee, Sung-Min;Park, Gyung-Soo;An, Kyoung-Ho;Park, Soung-Yun;Lee, Sang-Hee
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • A series of experiments were conducted to establish a marine ecotoxicological standard method using marine primary producers, Skeletonema costatum, Heterosigma akashiwo, Prorocentrum micans, Isochrysis galbana, Tetraselmis suecica as candidate test species. Marine diatom, S. costatum was selected as standard test species in terms of the ecological roles and international uses as test species. Test methods and test acceptability criteria are as follows; $72{\sim}96$ hr population growth inhibition $EC_{50}$ as endpoint. Static non-renewal method, and population growth rates over 0.04/hr in control as test acceptability criterium. S. costatum is widely distributed in the world ocean and used for standard species of marine toxicity test method by ISO (International Standardization Organization). Possible salinity ranges for this test method are $20{\sim}35\;psu$, and reproducibility and interlaboratory test results were consistent through the calibration tests. Sensitivity of the test method was comparable or better than other toxicity tests such as rotifer neonate mortality, bioluminescent bacterial inhibition, seaweed sporulation and sea urchin fertilization tests.

Development of Marine Toxicity Standard Method for Marine Luminescent Bacteria: Introduction of N-Tox test (해양성 발광박테리아를 이용한 해양환경 독성평가 시험법 개발: N-Tox test)

  • Lee, Kyu-Tae;Park, Gyung-Soo;Kim, Pyoung-Joong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.156-163
    • /
    • 2008
  • Luminescent bacterial toxicity test was first introduced in the early 1980s, registered as international standard method in 1998 and now widely used as a common toxicity test method. This toxicity test uses luminescent bacterium, Vibrio fischeri, originated from marine environment as a test organism. The degree of toxicity can be evaluated from the comparison of luminescent emission intensity between control and treatment groups to toxicants and materials from various environmental matrix for 30 min. This test can be carried out by using commercial products and its results are sensitive and precise. This research is on the feasibility of adopting luminescent bacterial test as a domestic standard test protocol. Using commercial products, a series of experiments were conducted to identify the precision and accuracy of injection volume and light emission, and to evaluate concentration-response relationship between chemical concentrations and light emissions. Also, the feasibility of the application to environmental media and quality assurance/quality control were checked. The results of serial toxicity tests revealed that the preliminary luminescent bacterial toxicity test was robust and suitable as a standard method.

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Endurance test procedure and validation of Multipurpose tactical vehicle (다목적 전술차량의 주행내구도 시험 절차 및 검증)

  • Jeong, Eui-Bong;Kang, Dong-Suk;Choi, Ji-Ho;Kim, Han-Shang;Choi, Man-Sick
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.256-261
    • /
    • 2014
  • Endurance test procedures of multipurpose tactical vehicle is constructed by comparing the Korea defence standard and TOP-2-2-506. The plan was to make the best reflect the operational environment and the actual production purposes. Endurance test of multipurpose tactical vehicle more stringent than the existing other military vehicles validation procedures. But the test plan, it is possible to reduce the cost and schedule of long verification that occurs because of the Endurance test. Through a comparison of the dynamic characteristic analysis, change of test center was to ensure the reliability and validity.

  • PDF

Reduction Effect of liquefaction by Vibro-Replacement Stone Columns (진동치환 스톤칼럼공법에 의한 액상화 저감 효과)

  • Lee, Song;Chae, Jum-Sik;Park, Sang-Kuk
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.443-450
    • /
    • 2001
  • This paper shows the reduction effect of tile earthquake-induced liquefaction potential of soils that improved by Vibro-Replacement Stone Columns. The Vibro-Replacement Stone Columns method transforms soft cohesive soils into a composite mass of compacted granular or crushed stone columns by using vibrating equipment and water jets. This study investigated and analyzed the behavior of the stone columns and composite ground using the results of in situ test and measurement at the job-site. This paper shows the evaluation of the earthquake-induced liquefaction potential of soils using in situ test. There are different types of in situ test used in the evaluation the liquefaction potential. In the particular study the Standard penetration test, and Cone penetration test were used. The N value of Standard Penetration test has been used all over for a very long time. The evaluation of the liquefaction of soil was performed using the worldwide renewed Cone penetration test

  • PDF

Study on Surface Treatment and Test over the Barrel of Small Arms (개인화기 총열 표면처리 및 시험에 관한 연구)

  • Chae, Je-Wook;Kim, In-Woo;Lee, Young-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.722-727
    • /
    • 2004
  • This paper includes the comparative study between Cr plating and nitriding process with an aim at improving corrosion, wear and maintainability for KNR(Korean Next Generation Rifle) 5.56mm barrel. The endurance test was conducted to compare the performance of standard barrel, Cr plating barrel and nitriding barrel. Main activities are described as follows; optimal Cr plating and nitriding process set-up for KNR 5.56mm barrel; durability test of each barrel(20,000 rounds); salt water immersion test; dispersion, initial velocity, inner diameter data acquisition. According to the results of this firing test, Cr plating barrel is superior to standard barrel and nitriding barrel in view of corrosion, wear and maintainability

  • PDF

A Study on Daily Temperature Cycle of Environmental Test in the Korean Peninsula (한반도 지역의 환경시험 온도 일주기 연구)

  • Lee, Jeong-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.62-70
    • /
    • 2007
  • Most design temperature of environmental test in korea is based on the standard of Department of Defense. There are few studies to establish temperature standard. Besides the representative environmental test guide 'MIL-STD-810F' encourage to tailor to generate the most relevant test data possible and to test to make a match of test environment with operational environment. Under these circumstances, it is irrational to comply with baseless daily cycle. Thus the study about design method of test temperature is essential. So, the daily cycles to be appropriate to the Korean peninsula was presented in this study. And this research shows how to derive two main element, frequency-of-occurrence and daily maximum (minimum) temperature in daily cycles, in case we can not find the daily cycle.

Effects of Nursing Students' Knowledge, Awareness and Moral sensitivity of standard precautions on Performance of standard precautions (간호대학생의 표준주의 지침에 대한 지식, 인지도 및 도덕적 민감성이 표준주의 지침 수행에 미치는 영향)

  • Jang, Hee-jung;Mo, Moon-hee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.441-448
    • /
    • 2021
  • The purpose of this study were to investigate knowledge, awareness, and moral sensitivity, performance of standard precaution, and to identify influencing factors on performance of standard precaution of nursing students. The subjects of this study were completed by 201 nursing students from 2 colleges in D City. Data were collected from December 2 to 20, 2019. Data were analyzed using the t-test, the ANOVA, the Pearson correlation coefficient, and multiple regression analysis by SPSS ver. 21.0. There were significant positive correlations among knowledge of standard precaution, awareness of standard precaution, and moral sensitivity on performance of standard precaution. The factors influencing performance of standard precaution of the study subjects were awareness of standard precaution(β=.78, p<.001), and the explanatory power of these variables was 60.5%. The development of awareness of standard precaution education program that focuses awareness of standard precaution change is needed.