• Title/Summary/Keyword: test results

Search Result 71,437, Processing Time 0.083 seconds

Static load test of the bogie and vibration performance test, dynamic characteristics analysis of the bulk cement car (벌크시멘트화차의 대차 하중시험과 진동성능시험 및 동특성 해석 연구)

  • 홍재성;함영삼;백영남
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.3
    • /
    • pp.186-193
    • /
    • 2003
  • The object of this study is to ensure the stability of bulk cement cars conducting vibration performance test, dynamic characteristic analysis and static load test of bogie frame. In case of static load test, bogie static load test facility was used. In case of dynamic characteristic analysis, Vampire Software was used. In case of vibration performance test, real bulk cement cars were used in kyeung-bu line. In the results of static load test of bogie frame for bulk cement car, all structures satisfied allowable stress criteria of materials. The vibration performance test and dynamic characteristic analysis results satisfied allowable standards.

Loading Test Results of Wind Turbine Pitch/Yaw Bearing (풍력발전기용 피치/요 베어링의 하중 시험 결과)

  • Nam, Ju-Seok;Kim, Heung-Sub;Lee, Young-Soo;Han, Jeong-Woo
    • Journal of Wind Energy
    • /
    • v.3 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • The loading test of wind turbine pitch and yaw bearings have been conducted using special test rig designed for the test of large slewing bearings. Test type was fatigue test that applied fatigue load to each bearing and followed the defined test process. Measurement data during test were rotational torque and raceway temperature, and inspected key components by disassembling the bearing after all test finished. As a results, the raceway temperature during test did not exceed the operational temperature range of lubricant and rotational torque was reduced as the bearing's rotational cycle increased. In the inspection of key components, some plastic deformation and flaking were detected at some raceway sections while other components such as ball, spacer and seal remain indefective conditions.

Pulp Vitality Evaluation and Comparison with Old Methods Using Pulse Oximetry (맥박산소측정기(pulse oximetry)를 이용한 치수 생활력 측정과 기존 방법과의 비교)

  • Kwon, Ik-Jae;Seo, Kwang-Suk;Kim, Jung-Wook;Chang, Ju-Hea;Kong, Hyoun-Joong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • Background: This study evaluated pulp vitality of anterior permanent teeth using pulse oximetry (PO), which is already used for monitoring of patient's $SpO_2$ and pulse rates (PR). Also we compared with ice tests and electric pulp test (EPT). Methods: 9 teeth, endodontic treated, were selected as non-vital teeth group. 17 vital teeth were selected as control group. Our aim is to compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of ice test, electric pulp test and pulse oximetry, respectively. Pulse oximetry has two test results, $SpO_2$ and pulse rates. Also we calculated correlation and statistical significances by Pearson's test between EPT and pulse oximetry. Results: Sensitivity, specificity, PPV, NPV were calculated on each tests. Ice test has results of 1.00, 0.89, 0.94 and 1.00, respectively. EPT has results of 0.94, 0.78, 0.89 and 0.88 respectively. $SpO_2$ has results of 0.94, 1.00, 1.00 and 0.90, respectively. PR has results of all 1.00. Conclusions: PO showed relatively accurate, stable and objective results on both $SpO_2$ and PR. Percentage of ability of accurate diagnosis for vital teeth is 94% for ice test, 89% for EPT, 100% for $SpO_2$ and PR. Percentage of ability of accurate diagnosis for non-vital teeth is 100% for ice test, 88% for EPT, 90% for $SpO_2$ and 100% for PR. In additions, PR could be more accurate and significant tests than $SpO_2$.

A Case Study on Reliability Growth Analysis for a missile System composed of All-Up-Round Missile and Launcher (유도탄 및 발사체계로 구성된 유도무기체계의 신뢰도 성장 분석 사례 연구)

  • Jo, Boram
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.329-335
    • /
    • 2019
  • Reliability growth analysis was conducted for a guided weapons system. In the development phase, reliability management activities were continuously carried out by identifying failure modes and causes and analyzing faults found during the testing. The missile system consists of an all-up-round missile and a launcher, and the analysis was carried out according to the test results of each system. The test results for the all-up-round missile were obtained with discrete data, which were success and failure as a one-shot-device. The test results for the launcher were obtained with continuous data by operating the equipment continuously in the test. For each test result, the reliability growth model was applied to the Standard Gompertz model and the Crow-Extended model. The models were used to identify the growth analysis results of the test so far. It was also possible to predict the reliability growth results by assuming the future test results. The study results could be useful in achieving the desired reliability goal and in determining the number of tests. Then, the planned test will be confirmed and the growth analysis of the missile system will continuously be conducted.

스용차용 알루미늄휠의 구조해석

  • 노병욱;배서인;김득규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.822-825
    • /
    • 1995
  • Linear elastic stress analysis of aluminum wheel was studied using ANSYS and Unigraphics. The load condition of wheel impact test was replaced whit static force using energy valance concept. And the results were compared with strain gaga test. The test results were good agreement with analysis results.

  • PDF

Full Scale Model Test on Channel Type PC Bridge (찬넬형 PC교의 실물실험 연구)

  • 구민세;황윤국;조현준;유영찬;김정호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.89-94
    • /
    • 1990
  • This study was performed to verify the behavior of channel type PC bridge through the full scale model test. It is well known that the behavior of connection is especially important in case of precast multi-beam bridges. In this study, the lateral load distribution capacity was found satisfactory and influenced little either by the type or strength of connections. Analysis results agreed well with test results. Parameter studies were performed based on the test and analysis results.

  • PDF

RF Compatibility Test Results of COMS satellite with Launch Vehicle (천리안위성의 발사체와의 전자파 적합성 시험결과 분석)

  • CHOI, Jae-Dong
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.215-217
    • /
    • 2010
  • This paper describes the test results of radiated compatibility with Ariane 5 launcher performed on the COMS Satellite test facility. Firstly, the Radiated Emission test results are analyzed in compliance with the Radiated Susceptibility requirement specification of Ariane 5 launcher. The satellite nominal operation is monitored during injection a radiated electric field corresponding to the launcher emissions levels in critical frequency ranges. And also, E-field are measured through a probe located at external units level in order to assess the EMC safety margin in Radiated mode.

  • PDF

Whole-Blood Gene-Expression Profiles of Cows Infected with Mycobacterium avium subsp. paratuberculosis Reveal Changes in Immune Response and Lipid Metabolism

  • Shin, Min-Kyoung;Park, Hong-Tae;Shin, Seung Won;Jung, Myunghwan;Im, Young Bin;Park, Hyun-Eui;Cho, Yong-Il;Yoo, Han Sang
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.2
    • /
    • pp.255-267
    • /
    • 2015
  • Mycobacterium avium subsp. paratuberculosis (MAP) is the causative agent of Johne's disease, a chronic debilitating disease affecting ruminants worldwide. In the present study, we aimed to determine the major gene networks and pathways underlying the immune response to MAP infection using whole-blood cells, as well as provide the potential transcriptional markers for identifying the status of MAP infection. We analyzed the transcriptional profiles of whole-blood cells of cattle identified and grouped according to the presence of MAP-specific antibodies and the MAP shed by them. The grouping was based on the results obtained by ELISA and PCR analyses as follows: i) Test1 group: MAP-negative results obtained by ELISA and positive results obtained by PCR; ii) Test2 group: MAP-positive results obtained by ELISA and negative results obtained by PCR; iii) Test3 group: MAP-positive results obtained by ELISA and positive results obtained by PCR; iv) uninfected control: MAP-negative results obtained both by ELISA and PCR analysis. The results showed down-regulated production and metabolism of reactive oxygen species in the Test1 group, activation of pathways related to the host-defense response against MAP (LXR/RXR activation and complement system) in the Test2 and Test3 groups, and anti-inflammatory response (activation of IL-10 signaling pathway) only in the Test3 group. Our data indicate a balanced response that serves the immune-limiting mechanism while the host-defense responses are progressing.

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.

A Fundamental Study of Rejuvenator for Warm in Place Recycling Asphalt Pavement Mixtures (현장 중온 재생 혼합물용 재생첨가제의 기초적인 연구)

  • Park, JaeYoung;Lee, Kanghun;Kwon, SooAhn;Lee, JaeJun
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.13-20
    • /
    • 2017
  • PURPOSES : This research was a laboratory study for evaluating the Reclaimed Asphalt Pavement (RAP) mixture added developed rejuvenator for warm mix recycling. Waste asphalt mixtures occupy about 18.2% of construction wastes in Korea. Moreover, most rejuvenators were imported from Europe or the U.S. Therefore, improving usage of RAP with a developed rejuvenator material provides environmental protection at a reduced cost. METHODS : The specimen used for this experiment was performed by only using RAP. A suitable rejuvenator for Target PG was then added. In addition, a conventional rejuvenator was selected to compare performance and specimens introduced with the same procedure as the developed rejuvenator was prepared. In order to evaluate rutting resistance and water susceptibility, we conducted a deformation strength test, a tensile strength ratio test, and a dynamic immersion test with the prepared mixtures. RESULTS :Laboratory test results indicated that both the developed additive and conventional additive improved performance of the recycled asphalt mixtures compared to mixtures without the rejuvenator. In addition, the deformation strength test and TSR test results satisfied standards for domestic recycling asphalt mixtures. The dynamic immersion test showed that the developed rejuvenator has superior scaling resistance than the conventional rejuvenator. CONCLUSIONS : In terms of rutting resistance and moisture susceptibility, the warm mix recycled asphalt mixtures with the developed rejuvenator appeared to effectively recovered performance.