• Title/Summary/Keyword: test facility

Search Result 1,836, Processing Time 0.025 seconds

Family Care-givers' Perceptions of Welfare Facility for Elderly People with Dementia (치매노인 주부양자의 노인복지시설에 대한 인식)

  • Cho, Myoung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study was to investigate the family care-givers' perceptions of welfare facility for the elderly people with dementia, to analyze the related variables, and to provide the suggestions from the perspectives of the well-being of family care-givers. The survey was done using questionnaires in 1999, and the subjects were 198 primary care-givers for senile dementia patients. Frequency distribution, mean, t-test, and one way ANOVA were used to analyze the data. The major findings of this study were as follows: The family care-givers' perceptions of the welfare facility for elderly people with dementia was relatively low. The variables associated were sex, education level, occupation and relationship with the demented elderly. The conclusion suggested from this study was that the social welfare facilities and services were necessary for both the demented elderly people themselves and their family care-givers.

  • PDF

Development of Short-circuit Testing Facility for Distribution Transformers (배전용 변압기 단락강도 시험설비 개발)

  • Park, Ji-Hun;Min, Yun-Hong;Kang, Young-Hak;You, Ho-Keun;Ahn, Kyu-Sun;Ham, Gil-Ho;Oh, Chang-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.64-67
    • /
    • 2002
  • To increase the short-circuit testing capacity of distribution transformers, testing facility has been installed for KEPCO in Vi-wang. The power supply of testing facility is directly supplied from the network substation located closely. Testing can be performed up to 300 kVA for single-phase transformers, 500 kVA for three-phase transformers. Operating with this facility, the distribution company is able to maintain the reliable supply of electricity. Also the critical quality of transformers from manufacturers can be verified by short-circuit testing. This paper describes the design concept and specification of newly developed equipment and the procedure of short-circuit test.

  • PDF

Algorithms on layout design for overhead facility (천장형 설비의 배치 설계를 위한 해법의 개발)

  • Yang, Byoung-Hak
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.133-142
    • /
    • 2011
  • Overhead facility design problem(OFDP) is one of the shortest rectilinear flow network problem(SRFNP)[4]. Genetic algorithm(GA), artificial immune system(AIS), population management genetic algorithm (PM) and greedy randomized adaptive search procedures (GRASP) were introduced to solve OFDP. A path matrix formed individual was designed to represent rectilinear path between each facility. An exchange crossover operator and an exchange mutation operator were introduced for OFDP. Computer programs for each algorithm were constructed to evaluate the performance of algorithms. Computation experiments were performed on the quality of solution and calculations time by using randomly generated test problems. The average object value of PM was the best of among four algorithms. The quality of solutions of AIS for the big sized problem were better than those of GA and GRASP. The solution quality of GRASP was the worst among four algorithms. Experimental results showed that the calculations time of GRASP was faster than any other algorithm. GA and PM had shown similar performance on calculation time and the calculation time of AIS was the worst.

The study on relation between ocular function and accommodative facility (시기능과 조절 용이성과의 관계 연구)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • To assess convergence and accommodation at a short distance, 92 selected subjects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT 10) at a short distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA). BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D flipper. Bernell Co., USA), vergence facility(prism flipper, Bernell Co., USA). There were such test results as MEM retinoscopy(R/L)($+1.05{\pm}0.87/1.02{\pm}0.80$ D). BELL retinoscopy ($17.89{\pm}12.12/17.94{\pm}11.72cm$), binocular accommodative facility (R/G)($7.69{\pm}6.48cpm$). binocular accommodative facility(polaroid)($11.76{\pm}5.22cpm$), monocular accommodative facility(R/L) ($13.9{\pm}6.27/13.8{\pm}5.96cpm$), vergence facility($13.5{\pm}6.40cpm$).

  • PDF

Construction and Application of Urban Foundation Facility Electronic Library in Ubiquitous Computing Environment (유비쿼터스 시대의 도시기반시설물전자라이브러리 구축 및 활용 방안)

  • Jin, Hai-Ming;Kim, Byung-Guk;Sung, Jung-Gon;Park, In-Man
    • Journal of Korea Spatial Information System Society
    • /
    • v.8 no.3
    • /
    • pp.27-37
    • /
    • 2006
  • It defined the standard list of the urban foundation facility which from the local self-government it is managing with commonness and standard items and standard option and a construction plan it drew up "Urban Foundation Facility Electronic Library" it researched. "Urban Foundation Facility Electronic Library" defines with the aggregate of the component DB which lets to collect the organization, quality and form of the urban Foundation facility back attribute item system from the Geographic Information System(GIS). Consequently after the "Urban Foundation Facility Electronic Library" is constructed, it presented the application plan from on-the-spot inspection. Also it applied in the ubiquitous environment which is actualized quickly the plan which it does in the RFID and sensor network and electronic library grafting it presented. The connection use of the RFID and was possible from the Facility civil official test which applies the RFID.

  • PDF

Assessment of Accommodative Facility in General Binocular Dysfunctions (양안시이상에 따른 조절용이의 평가)

  • Park, Sang-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.51-57
    • /
    • 2009
  • Purpose: The purpose of this study was to determine if monocular and binocular accommodative facility tests would be useful in diagnosing general binocular dysfunctions. Methods: 95 symptomatic children, who were selected from comprehensive vision tests, were classified into four groups (29 subjects with accommodative dysfunctions, 28 subjects with vergence dysfunctions, 25 subjects with combined accommodative and vergence dysfunctions, 13 subjects with normal binocular functions). Monocular and binocular accommodative facility was measured with ${\pm}$2.00 D flipper lenses. Results: Statistical analysis revealed that binocular accommodative facility measurement was significantly lower than monocular accommodative measurement in the vergence dysfunction group (p<0.01). However, there were no differences between monocular and binocular accommodative facility measurements in the group of accommodative or combined accommodative and vergence dysfunction (p>0.05). In addition, subjects with general binocular dysfunctions performed significantly poorer than subjects with normal binocular function on monocular and binocular accommodative facility (p<0.000). Conclusions: As a result of this study, monocular and binocular accommodative facility test, which could differentiate dysfunction from normal as well as between dysfunctions, indicated useful means for diagnosis of general binocular dysfunctions.

  • PDF

Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings

  • Gol-Zaroudi, Hamzeh;Aly, Aly-Mousaad
    • Wind and Structures
    • /
    • v.25 no.3
    • /
    • pp.233-259
    • /
    • 2017
  • Investigations on simulated near-surface atmospheric boundary layer (ABL) in an open-jet facility are carried out by conducting experimental tests on small-scale models of low-rise buildings. The objectives of the current study are: (1) to determine the optimal location of test buildings from the exit of the open-jet facility, and (2) to investigate the scale effect on the aerodynamic pressure characteristics. Based on the results, the newly built open-jet facility is well capable of producing mean wind speed and turbulence profiles representing open-terrain conditions. The results show that the proximity of the test model to the open-jet governs the length of the separation bubble as well as the peak roof pressures. However, test models placed at a horizontal distance of 2.5H (H is height of the wind field) from the exit of the open-jet, with a width that is half the width of the wind field and a length of 1H, have consistent mean and peak pressure coefficients when compared with available results from wind tunnel testing. In addition, testing models with as large as 16% blockage ratio is feasible within the open-jet facility. This reveals the importance of open-jet facilities as a robust tool to alleviate the scale restrictions involved in physical investigations of flow pattern around civil engineering structures. The results and findings of this study are useful for putting forward recommendations and guidelines for testing protocols at open-jet facilities, eventually helping the progress of enhanced standard provisions on the design of low-rise buildings for wind.

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

Suppression of stray electrons in the negative ion accelerator of CRAFT NNBI test facility

  • Yuwen Yang ;Jianglong Wei ;Junwei Xie ;Yuming Gu;Yahong Xie ;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.939-946
    • /
    • 2023
  • Comprehensive Research Facility for Fusion Technology (CRAFT) is an integration of different demonstrating or testing facilities, which aim to develop the critical technology or composition system towards the fusion reactor. Due to the importance and challenge of the negative ion based neutral beam injection (NNBI), a NNBI test facility is included in the framework of CRAFT. The initial object of CRAFT NNBI test facility is to obtain a H0 beam power of 2 MW at the energy of 200-400 keV for the pulse duration of 100 s. Inside the negative ion accelerator of NNBI system, the interactions of the negative ions with the background gas and electrodes can generate abundant stray electrons. The stray electrons can be further accelerated and dumped on the electrodes or eject from the accelerator. The stray electrons, including the ejecting electrons, cause the unwanted particle and heat flux onto the electrodes and the inner components of beamline (especially the temperature sensitive cryopump). The suppression of the stray electrons from the CRAFT accelerator is carried out via a series of design and simulation works. The paper focuses the influence of different magnetic field configurations on the stray electrons and the character of the ejecting electrons.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.