• Title/Summary/Keyword: test facility

Search Result 1,836, Processing Time 0.025 seconds

Development of Concrete Quality Inspection and Document Management System Using Mobile and Web Technologies (모바일 기술 및 웹을 활용한 콘크리트 품질시험 및 문서관리 시스템 개발)

  • Kim, Young-Suk;Lee, Jae-Kwon;Jung, Un-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.4
    • /
    • pp.193-205
    • /
    • 2008
  • Quality is an important keyword representing the corporate competitiveness and image in today' s construction industry. Especially in concrete construction, any problems or defects in fresh concrete can significantly degrade the entire quality and performance of the facility built. Thus, adequate quality inspection and testing must be exercised over the fresh concrete, if concrete with the required strength, durability and appearance is to be obtained. The testing of concrete delivered to the construction job site involves testing of fresh concrete and performing strength tests on hardened concrete. The principal tests conducted on fresh concrete include the slump test and tests for air and salt content. The temperature of fresh concrete should be checked out hot or cold weather concreting. The 7-day and 28-day strength of hardened concrete are also determined by compression tests on usually cylinder samples. However, it is very complex and time-consuming process requiring a lot of efforts to document those on-site concrete testing results and to accumulate their historical data. The primary objective of this study is to suggest a unique PDA and web-based system which enables an on-site quality manager to effectively conduct the concrete inspection and testing, automatically document and accumulate the collected historical data, and promptly obtain the approval from supervisors. Finally, it is anticipated that the effective use of the proposed PDA and web-based system would be able to improve reliability of the concrete quality inspection and testing data as well as significantly reduce the approval process.

Construction of Kobe′s World Cup Venue and the Development of an Urban Resort

  • Tanaka, Mitsru;Hayashi, Mayumi
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.1
    • /
    • pp.230-236
    • /
    • 2001
  • The usual definition of and urban resort was a place vastly different from places of daily life such as a theme park or other tourist destination. At the same time, revival of the combination of usual and unusual spaces, in a way like the mixed "Hare"(Special occasion of public event) and "Ke"(Daily life) spaces of communities of old Japan, is part of the idea of urban resorts. And they are places, which start by making a comfortable urban environment for citizens, providing a daily life full of culture and promoting a city′s identity to visitors. if we think about the kinds of structural elements of urban resorts, the usual elements include community, local culture and industry, while the unusual elements include symbols, festivities and interaction. Kobe Wing Stadium is a venue for the 2002 FIFA World Cup hosted by Korea and Japan. The city will build the stadium, but after construction management will be given over to private enterprise, hoping to utilize that sector′s business know how. A competition was held to determine the private executor who would be entrusted with the planning, design, construction and management of the project, considering the conditions of the area, the stadium′s relationship to it and local revitalization. The competition was won by a private enterprise (Kobe Steel Obayashi Group). The them of "Creation of a Sports Community Park" grapples with the large issue of the facility′s relationship with the community. American geographer Yi-fu Tuan coined the word "topophilia" to indicate love of a place. No other word could better describe the desired urban resort nature of the stadium. From this historical perspective it seems that stadiums have great potential as urban resorts. The factor that will determine their success is the attitude of citizens toward them, in short whether they develop topophilia for them or not. We examined the urban resort nature of Kobe Wing Stadium. Regarding daily life, we saw the attempts to revive the local community, the possibility of deepening the local culture and the weakened state of local industry. As a place that is for more than daily life, we saw the certainty of the stadium′s symbolism, its potential as a place for festivities and the test it will face as a space for interaction. Even though several issues are left for future resolution, evaluating Kobe Wing Stadium through these elements of an urban resort, it is clearly founded in the daily life of the community while providing a venue for "Hare"occasions. Fulfilling the roles of an urban resort, it provides many opportunities for local residents to enjoy their and gives visitors a reason to come repeatedly.

  • PDF

A Study on the Self-confidence in Performance and Education Demand of First Aid in Kindergarten and Daycare Center Teachers (유치원 및 어린이집 교사의 응급처치 수행자신감 및 교육요구도)

  • Hwang, Ji-Young;Oh, Eun-Soon;Cho, Keun-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.234-243
    • /
    • 2016
  • The aim of this study was to identify the self-confidence in performance and education demand of first aid in kindergarten and daycare center teachers. The data from a questionnaire were collected from teachers in kindergarten and daycare centers from March 5 to 31, 2015. The responses from 149 teachers were analyzed using SPSS 21.0. The results showed that self-confidence in the performance of first aid was mostly low (mean score 2.70), but was significantly high in cases of having a willingness to perform first aid (p=.002). The education demand for first aid was mostly high (mean score 4.04), and significantly high in the case of having experience of emergency situations (4.21, p=.006), and being educated in first aid while working in a childcare facility (4.14, p=.001). Therefore, it is important to educate teachers in first aid regularly after developing an optimized program considering the frequency of emergency situations, and level of self-confidence in the performance and education demand of first aid.

Intelligent Broadcasting System and Services for Personalized Semantic Contents Consumption (개인화된 의미 기반 콘텐츠 소비를 위한 지능형 방송 시스템과 서비스)

  • Jin, Sung Ho;Cho, Jun Ho;Ro, Yong Man;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.422-435
    • /
    • 2005
  • Compared with analog broadcasting, digital broadcasting supports technical background to provide personalize the TV watching environment by offering broadcasting services that can adapt to viewers' preferences. However, current digital broadcasting shows limited services such as reservation recording, simple program guiding with an electronic program guide (EPG) on a personal video recorder system, and primitive data broadcasting by broadcasters. Therefore, the purpose of this paper is to suggest a new broadcasting environment which gives a person facility and a difference fur watching TV by serving enhanced personalized services. For that reason, we propose an intelligent broadcasting system which can minimize viewer's actions, and enhanced broadcasting services which are based on understanding of the semantics of broadcasting contents. To implement the system, agent technology as well as the MPEG-7 and TV-Anytime Forum (TVAF) are employed. For content-level services, real-time content filtering and personalized video skimming are designed and implemented. To verify the usefulness of the proposed system, we demonstrate it with a test-bed on which content-level personalized services are implemented.

Maintenance of Infiltration-type Facilities for Non-point Source Pollutant (침투형 비점오염원 처리시설의 유지관리에 관한 연구)

  • Lee, Hosik;Lee, Sanghwan
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.145-152
    • /
    • 2013
  • This study was conducted to improve the Nonpoint-source pollutant treatment plant efficiency and maintenance. Field and laboratory permeability test were conducted three times each before and after displacement. The removal efficiency such as TSS, BOD, CODmn, T-N, and T-P were investigated from the year of 2006 to 2011. The coefficient of permeability right after displacement was calculated to be $1.07{\times}10^{-3}(cm/s)$, coefficient of permeability after a year was calculated to be $0.88{\times}10^{-3}(cm/s)$, and after five years, it was calculated to be $0.3{\times}10^{-3}(cm/s)$ and accordingly, the amount of infiltration decreased. In case of the removal efficiency, it generally tended to decrease, but it showed the higher rates than the expected rates BOD 40%, SS 76%, T-N 39% and T-P 53%. It is concluded that displacement cycle should be at least five years and that dredging cycle should be at least three months and at most one year.

A study on the Operation Algorithm for Bi-directional Sectonalizer in Distribution System Interconnected with Distributed Generations (분산전원이 연계된 배전계통의 양방향 구간개폐기의 동작 알고리즘에 관한 연구)

  • Yoon, Gi-Gab;Jeong, Jum-Soo;An, Tae-Pung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1802-1809
    • /
    • 2009
  • Abstract The typical distribution systems have the power flow from distribution substations (sources) to customers (load) only as one direction. However, in the case where distributed generations (DG) such as PV system and wind power systems are connected to distribution systems, the DG output variations to distribution systems, so called reverse power flow, may cause the bi-directional power flow. So, the reverse power flow has severe impacts on typical power system, for example power quality problems, protection coordination problems, and so on. Especially, protection devices (sectionalizer) in primary feeder of distribution system interconnected with distributed generations may cause problems of malfunction, and then many customers could have problems like an interruption. So, this paper presents the bi-directional operation algorithm of protection devices to overcome the problems like mal-function. And, also this paper shows the effectiveness of proposed method by using both PSCAD/EMTDC software and test facility of protection devices to simulate the field distribution systems.

Development of Work Breakdown Structure and Analysis of Precedence Relations by Activity in School Facilities Construction Work (학교시설 건설공사의 작업분류체계 구축 및 단위작업별 선후행 관계 분석)

  • Bang, Jong-Dae;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.189-200
    • /
    • 2017
  • The work breakdown structure and the precedence relations by work activity are very important because they are the basic data for estimating the construction duration in the construction work. However, there is no standard to accurately estimate the construction duration since the size of the school facilities construction is smaller than the general construction work. Therefore, some schools are unable to open in March or September and the delay of the construction duration can cause damage to the students. To solve this problem, this study developed a work breakdown structure of school facilities construction work and analyzed the precedence relations by work activities. The work breakdown structure of the school facilities construction is composed of three steps. The operations corresponding to level 1 and level 2 are as follows. (1) 2 preparatory work categories; preparation period and temporary construction. (2) 17 architectural work categories; temporary construction, foundation & pile work, reinforced concrete work, steel roof work, brick work, plaster work, tile work, stone work, waterproof construction, wood work, interior construction, floor work, metal work, roof work, windows construction, glazing work and paint construction. (3) 7 mechanic and fire work categories; outside trunk line work, plumbing work, air-conditioning equipment work, machine room work, city gas plumbing work, sanitation facilities and inspection & test working. (4) 4 civil work categories; wastewater work, drainage work, pavement work and other work. (5) 1 landscaping work categories; planting work. The work breakdown structure was derived from interviews with experts based on the milestones and detailed statements of existing school facilities. The analysis of precedence relations by school facilities work activity utilized PDM(Precedence Diagramming Method)which does not need a dummy and the relations were applied using FS(Finish to Start), FF(Finish to Finish), SS(Start to Start), SF(Start to Finish). The analysis of this study shows that if one work activity is delayed, the entire construction duration may be delayed because the majority of the works are FS relations. Therefore, it is necessary to use the Lag at the appropriate time to estimate the standard construction duration of the school facility construction. Lag is a term used only in the PDM method and it is used to define the relationship between the predecessor and the successor in creating the network milestone. And it means the delay time applied to the two work activities. The results of this study can reasonably estimate the standard construction duration of school facilities and it will contribute to the quality of the school facilities construction.

Case Study on the Improvement of Pollutant Removal Efficiency in Sihwa Constructed Wetland (시화호 인공습지의 수질정화기능 향상을 위한 사례연구)

  • Choi, Don-Hyeok;Kang, Ho;Choi, Kwang-Soon
    • Journal of Wetlands Research
    • /
    • v.12 no.2
    • /
    • pp.25-33
    • /
    • 2010
  • Three plans(induction of water flow, supply of oxygen into water, control of fish causing resuspension of solids) proposed to improve the pollutant removal efficiency of Sihwa Constructed Wetland(CW) were estimated by considering the their efficiency and application to the wetland. After construction of facility for induction of water flow in lower part(W 122m${\times}$L 103m) of the wetland, the mean removal efficiencies of BOD, SS, TN and TP were in range of 12.8~37.4% and BOD was showing the highest efficiency. This result indicates that water flows is one of very important factors in the pollutant removal of wetland, especially near the outlet of a large scale wetland such as Sihwa CW. Dissolved oxygen(DO) concentrations after operation of two oxygen supply systems such as Air Bubble Diffuser and Surface Aeration System increased 15.5% and 27.2%, respectively. For maintaining effective DO concentration in Sihwa CW, the operation of oxygen supply system may be desirable during midnight to dawn in the location in which DO concentration is not enough, for instance less than 2 mg/L in CW. In experiments of the fish removal from Sihwa CW, the mean turbidity was lower in test site(6.2 NTU) than control site(10.6). The removal efficiency of thurbidity by th fish removal from the wetland was 41.5%. Therefore, a relevant fish management through a periodical monitoring of fish and turbidity is needed.

Development of tree box filter LID system for treating road runoff (LID 시설로서 도로에 적용 가능한 수목여과시설 개발)

  • Choi, Jiyeon;Son, Younggyu;Lee, Soyoung;Lee, Yuhwa;Kim, Lee Hyung
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.407-412
    • /
    • 2013
  • The aim of this study was to develop a tree box filter system, an example of Low Impact Development technology, for treating stormwater runoff from road. Monitoring of storm events was performed between June 2011 and November 2012 to evaluate the system performance during wet day. Based on the results, all runoff volume generated by rainfall less than 2 mm was stored in the system. The minimum volume reduction of 20% was observed in the system for rainfall greater than 20 mm. The greatest removal efficiency was exhibited by the system for total heavy metals ranging from 70 to 73% while satisfactory removal efficiency was exhibited by the system for particulate matters, organic matters and nutrients ranging from 60 to 68%. The system showed greater pollutant removal efficiency of 67 to 83% for rainfall less than 10 mm compared to rainfall greater than 10 mm which has 39 to 75% pollutant removal efficiency. The system exhibited less pollutant reduction for rainfall greater than 10 mm due to the decreased retention capacity of the system for increased rainfall. Overall, the system has proved to be an option for stormwater management that can be recommended for on-site application. Similar system may be designed based on several factors such as rainfall depth, facility size and pollutant removal efficiency.

Assessing Biosecurity Practices on Commercial Pig Farms across Korea and Risk Factors for Porcine Circovirus Type 2 Infection (국내 양돈장의 차단방역 수준 평가 및 돼지써코바이러스 2형 감염의 위험요인에 관한 연구)

  • Choi, Sung-Hyun;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.324-329
    • /
    • 2015
  • The primary aim of this study was to investigate biosecurity practices in pig farms and to determine the major risk factors associated with PCV2 infection for a sampled swine population in Korea. To this end, we analyzed data from a cross-sectional study of 296 farrow-to-finish farms, which was conducted between March and September 2014 to explore the prevalence of swine disease at farm level. Face-to-face interviews by on-site visit of trained veterinarians were conducted with the farm owners or managers using a standardized questionnaires with information about basic demographical data and management practices. Farms were classified as negative or positive through the use of infection profiles that combined data on serological testing including PCR antigen test result, antibody titer and sero-conversion pattern at each age category taking into account vaccination status. Data were analyzed using multivariate ordinal logistic regression. Results from this study indicated that biosecurity level of the farms was considered not good given low compliance of the biosecurity programs and facilities in the farm: off-site removal of dead stocks (7%), off-site location of storage facility for incoming feeds (12.6%), off-site pick-up location for finishers (19.3%), restrictions on feed supplier vehicles for farm entrance (19.6%), restriction of finisher trucks entering the farm (22.4%), and restriction on manure disposal trucks entering the farm (26.4%). In the final model (n = 255), allowance of finisher truck driver to the pig unit had increased risk of infection (OR = 2.4, 95% CI 1.22-4.67) whereas farms with a sign forbidding the entrance had decreased risk of infection (OR = 0.19, 95% CI 0.10-0.58). Further comprehensive research with larger sample size is required to better understand the multifactorial characteristic that some predisposing risk factors that were not available in this study. To the best knowledge of the authors, this was the first study to use empirical data to report risk factors associated with PCV2 infection in the Korean pig farms. Results from the current study could be used to decide optimal biosecurity measures to reduce the impact of PCV2 infection to farmers and policy makers.