• Title/Summary/Keyword: test chamber

Search Result 1,542, Processing Time 0.031 seconds

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Development of In Vitro Seedling Screening Method for Selection of Resistant Rice Against Bakanae Disease (벼 키다리병 저항성 검정을 위한 기내 유묘 검정법 개발)

  • Lee, Yong-Hwan;Lee, Myeong-Ji;Choi, Hyo-Won;Kim, Sung-Taek;Park, Jin-Woo;Myung, Inn-Shik;Park, Kyung-Seok;Lee, Se-Weon
    • Research in Plant Disease
    • /
    • v.17 no.3
    • /
    • pp.288-294
    • /
    • 2011
  • Rice bakanae disease, caused by the fungus Fusarium fujikuroi, is one of the most important rice diseases and distributed widely in Asia. Resistance screening system in rice field had been established. However, the evaluation results of the system vary according to the environmental conditions when the test is conducted. To develop precise and rapid evaluation method of disease resistance of rice to bakanae disease, in vitro screening system was attempted in this study. The six cultivars namely, 'Nampyeongbyeo', 'Junambyeo', 'Chucheongbyeo', 'Samcheonbyeo', 'Odaebyeo' and 'Hwasinbyeo' were tested. They were planted onto MS agar medium (10 ml) in test tube ($450\;mm{\times}{\phi}30\;mm$) and incubated at $25^{\circ}C$ and $28^{\circ}C$ in growth chamber under 12 hr light condition. Symptoms of over growth appeared a few days after seeding and then seedling were withered 2-3 weeks after over growth. The disease symptoms such as leaf dryness on top of rice were appeared in the 'Nampyeongbyeo' from 28 days at the concentration of $10^5$ spores/ml culturing at $28^{\circ}C$ and then withered completely 35 days after seeding. Whereas the other varieties withered entirely 19-23 days after seeding. Using the in vitro seedling screening method, 72 rice varieties were investigated to select resistant cultivar. Finally, two resistant cultivars ('Nampyeongbyeo' and 'Inwolbyeo') and seven moderately resistant cultivars ('Hwadongbyeo', 'Seokjeongbyeo', 'Samgwangbyeo', 'Sampyeongbyeo', 'Nonghobyeo', 'Heukjinjubyeo' and, 'Joanbyeo') were selected. If in vitro seedling screening method was used for evaluation of bakanae disease resistance, it would be completed within 35 days after sowing of rice seed.

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Classification for Types of Damages Caused by Cold Stress at Different Young Spike Development Stages of Barley and Wheat (맥류의 유수발육기 저온장해유형과 피해시기 분류)

  • 구본철;박문웅;김기준;안종국;이춘우;윤의병
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.3
    • /
    • pp.252-261
    • /
    • 2003
  • Although the young spike of barley (Hordeum vulgare L.) or wheat (Triticum aestivum L.) is known as the most susceptible part to spring cold injury, the risk of cold injury is apt to be ignored in most breeding program due to the importance of early maturity. Based on these aspects, the types and inducing time, temperature conditions for induction and effects of cold injury on growth and yield in this study were investigated under greenhouse and field conditions through three years (1997-1999). In natural condition, low temperature around -2.4∼$-10.2^{\circ}C$ caused the death of plant. Several cold injury types such as partial degeneration of spike, partial discoloration of leaf, spike and awn, discoloration of culm and white spike were observed at low temperature around $-3.1^{\circ}C$. Low temperature around -2.4∼$-8.6^{\circ}C$ and 1.3-$7.6^{\circ}C$ caused degeneration and sterility of spike, respectively. Most materials were prepared to the spikelet foundation stage, spikelet differentiation stage, development stage of flower organ, booting stage and heading stage, which were known having risk for cold injury in field condition. Although most of the controlled stages were sensitive to the induced low temperature, booting stage was the most sensitive stage for cold injury. All of growth stages which were treated-heading stage, booting stage, development stage of flower organ, spikelet differentiation stage, spikelet foundation stage-were responded to low temperature treatment but the symptoms revealed were very specific according to the growth stages. Ears of plant in heading stage were discolored to white. Ears of plant in booting stage were degenerated in all or part of one. Plants in spikelet differentiation stage were sterile in all or part of one. When tried to detect the specific differences between normal and cold injured plants in appearance, spike length, distance between spike and flag leaf and the first internode length could be the critical points for occurrence of spike death caused by cold injury. In barley, the elongation of spike was stopped on 3.2cm after occurrence of spike degeneration, 4.7cm after occurrence of partial degeneration of spike, 5.0cm after occurrence of white spike. In wheat, it was stopped on 1.6cm after occurrence of stem death, 3.3cm after occurrence of spike degeneration, 8.3cm after occurrence of partial degeneration of spike, 8.1cm after occurrence of white spike, 7.5cm after partial discoloration of leaf and 9.3cm after partial discoloration of spike. The obtained results from low temperature treatment induced in growth chamber were similar to the field experiment, Beacuse the death of spikes was more when low temperature was treated two times than one times, the temperature should be upgrade to -3$^{\circ}C$ in order to get the same condition with field test.

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF

A Experimental Study on Nitrous Oxide Formation in Direct Injection Diesel Engine (직접분사식 디젤엔진에서 아산화질소의 생성에 관한 실험적 연구)

  • Yoo, Dong-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.188-193
    • /
    • 2015
  • It has been generally recognized that $N_2O$(Nitrous Oxide) emission from marine diesel engines has a close correlation with $SO_2$(Sulfur Dioxide) emission, and diversity of fuel elements using ships affects characteristics of the $N_2O$ emission. According to recent reports, in case of existence of an enough large NO(Nitric Oxide) generated as fuel combustion, effect of the $SO_2$ emission in exhaust gas on the $N_2O$ formation is more vast than effect of the NO. Therefore, $N_2O$ formation due to the $SO_2$ element operates on a important factor in EGR(Exhaust Gas Recirculation) systems for NOx reduction. An aim of this experimental study is to investigate that intake gas of the diesel engine with increasing of $SO_2$ flow rate affects $N_2O$ emission in exhaust gas. A test engine using this experiment was a 4-stroke direct injection diesel engine with maximum output of 12 kW at 2600rpm, and operating condition was set up at a 75% load. A standard $SO_2$ gas with 0.499%($m^3/m^3$) was used for changing of $SO_2$ concentration in intake gas. In conclusion, the diesel fuel included out sulfur elements did mot emit the $SO_2$ emission, and the $SO_2$ emission in exhaust gas according as increment of the $SO_2$ standard gas had almost the same ratio compared with $SO_2$ rate in mixture inlet gas. Furthermore, the $N_2O$ element in exhaust gas was formed as $SO_2$ mixture in intake gas because increment of $SO_2$ flow rate in intake gas increased $N_2O$ emission. Hence, diesel fuels included sulfur compounds were combined into $SO_2$ in combustion, and $N_2O$ in exhaust gas should be generated to react with NO and $SO_2$ which exist in a combustion chamber.

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.