• Title/Summary/Keyword: test beam

Search Result 2,914, Processing Time 0.036 seconds

Study on the Optimization Design and Impact Experiment of Side Door for Impact Beam in the Vehicle Side Door (차량 측면도어 임팩트 빔의 최적설계 및 측면도어 충돌실험에 관한 연구)

  • Kim, Jae Yeol;Choi, Soon Ho
    • Tribology and Lubricants
    • /
    • v.31 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • The impact beam, a beam-shaped reinforcement installed horizontally between the inside and outside panels of car doors, is gaining importance as a solution to meet the regulations on side collision of vehicles. In order to minimize pelvis injury which is the biggest injury happening to the driver and passengers when a vehicle is subject to side collision, energy absorption at the door impact beam should be maximized. For the inner panel, the thrust into the inside of the vehicle must be minimized. The impact beam should be as light as possible so that the extent of pelvis injury to the driver and passenger during side collision of the vehicle is minimal. To achieve this, the weight of the impact beam, has to be optimized. In this study, we perform a design analysis with a goal to reduce the weight of the current impact design by 30% while ensuring stability, reliability, and comparison data of the impact beam for mass production. We conduct three-point bending stress experiments on conventional impact beams and analyze the results. In addition, we use a side-door collision test apparatus to test the performance of beams made of three (different materials: steel, aluminum, and composite beams).

Classification Schemes of Precast Beam-Column Connections According to Contribution of Deformation Components (변형기여분에 따른 프리캐스트 보-기둥 접합부의 분류방안)

  • Choi, Hyun-Ki;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.545-553
    • /
    • 2014
  • This study suggested an integrated classification method for generalized characteristics of PC beam-column connection according to connection details. Quantifying the failure mode of PC-beam column connection and characteristics of corresponding details, this study suggested to use deformation contribution of each element of beam-column assemblage. According to the expected failure mode of beam-column connection assemblage, PC beam-column connection can be classified into 'equivalent monolithic system' and 'jointed system'. In this study, four test specimens were tested for verification of detailed classification method of PC beam-column connections. Test was carried out with typical beam-column connection test method. Load was applied at the top of test specimen and end of beams were restrained by hinge. In order to verify the deformation contribution of each test specimen, 34-LVDTs were mounted on test specimen. According to test results, deformation contribution of each test specimen have different characteristics. Deformation characteristics of joint and other components which are quantified by test results, equivalent monolithic system can be classified into two categories. Strong connection have extremely small deformation contribution of joint and much larger deformation contribution was shown in flexural behavior of beam. The other type of beam-column connection is ductile connection which allows the larger deformation in joint area compared with strong connection.

A Method for Evaluation of Mechanical Accuracy of a Teletherapy Machine Using Beam Directions (방사선 진행방향을 이용한 원격치료장치의 기계적 정확성 평가방법)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.53-64
    • /
    • 1996
  • Purpose: The purposes of this paper are to develop a theoretical basis that the beam directions should be considered when the mechanical accuracy of teletherapy machine is evaluated by the star pattern test, to develop methods using asymmetric field in length to simulate beam direction for the case that beam direction does not appear on film. Method: In evaluating mechanical rotational accuracy of the gantry of teletherapy unit by the star pattern test, the direction of radiation beams was considered. A star pattern using some narrow beams was made. Density profiles at 10cm far from estimated gantry axis on the star pattern were measured using an optical densitometer. On each profile, one coordimate of a beam axis was determined. A pair of coordinates on a beam axis form an equation of the axis. Assume that a unit vector equation omitted is with same direction as radiation beam and a vector equation omitted is a vector directing to the beam axis from the estimated gantry axis. Then, a vector product equation omitted ${\times}$ equation omitted is an area vector of which the absolute value is equal to the distance from the estimated gantry axis to the beam axis. The coordinate of gantry axis was obtained by using least-square method for the area vectors relative to the average of whole area vectors. For the axis, the maximum of absolute value of area vectors would be an accuracy of the gantry rotation axis. For the evaluation of mechanical accuracies of collimator and couch axes for which beam direction could not be depicted on a star pattern test film, narrow beams asymmetric in field length was used to simulate beam direction. Result: For a star test pattern to evaluate the mechanical accuracy of rotational axes of a telectherapy machine, the result considering beam direction was different from that ignoring beam direction. For the evaluation of mechanical accuracies of collimator and couch axes by means of a star pattern test, narrow asymmetric beams could simulate beam direction. Conclusion: When a star pattern test is used to evaluate the mechanical accuracy of a teletherapy unit, beam direction must be considered or simulated, and quantitatively evaluated.

  • PDF

Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Reinforced bars (철근으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동)

  • Yoo, Yeong Chan;Shin, Kyung Jae;Oh, Young Suk;Lee, Seung Joon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.377-390
    • /
    • 1997
  • The objective of this study is to investigate the structural behavior of concrete-filled steel tubular column to H-beam connections with reinforced bar. As a preliminary test, simple tensile test on the column to H-beam connections stiffened were conducted. The parameters of tensile test are the diameters of each rebars. The simple tensile test were conducted to 5 kinds of specimens. Estimating the load. displacement and strain for specimens, the result of tensile test were compared with the results of main test. On the basis of simple tensile test, tests are conducted to montonic and cyclic loading column to H-beam connections with the same diameters of rebars. Specimens of 5 are made for monotonic and cyclic loading test. In analysis, estimating the yielding strength and maximum strength of specimens on the basis of yield line theory, strength formula of beam-to column connections with concrete-filled steel tubular column was suggested.

  • PDF

Experimental Evaluation on Seismic Performance of Filled Composite Beam - to - Forming Angle Composite Column Connections (충전형 합성보와 포밍앵글 기둥 접합부의 내진성능에 대한 실험적 평가)

  • Kim, Hyoung Seop;Lee, Kyungkoo;Koo, Jimo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.71-77
    • /
    • 2016
  • In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.

The Experimental Study on Structural Performance of the Beam-Slab System (보-슬래브 시스템 구조성능에 관한 실험적 연구)

  • Lee, Myung Jae;Kim, Cheol Hwan;Lee, Seung Joon;Kim, Won Ki;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.91-101
    • /
    • 2004
  • This study sought to suggest a structural design guide and to investigate the structural performances of the new beam-slab system in order to decrease the height of floors in high-rise steel structure apartments. Experiments were performed to assess the capacity of the new beam-slab system in a steel structure with 9.8-m span, particulary structural material test, pure bending test of composite beam, three-point bending test of composite beam, and bending and shearing tests. Results showed that the suggested composite beam had stable structural behavior when stud connectors were located in the upper flange, and upper bars were calculated normally according to the design of the slab.

A Study on the Simulation Model Verification for Performance Estimation of Torsion Beam Axle (토션빔액슬 성능 평가를 위한 해석 모델 검증에 관한 연구)

  • Choi, Sung-Jin;Park, Jung-Won;Jeon, Kwang-Ki;Lee, Dong-Jae;Choi, Gyoo-Jae;Park, Tae-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.107-113
    • /
    • 2006
  • The torsion beam axle type is widely used in the rear suspension for small passenger cars due to low cost, good performance, etc. To develop the torsion beam axle, it is necessary to estimate the characteristics of rear suspension from the design process. The characteristics estimation of the torsion beam axle is performed using FEM, dynamic simulation and is verified the real test. In this study, the natural frequency and roll stiffness of the torsion beam axle were measured by FEM, and the reliability of the FE model was evaluated according to the comparison of test data. This study presents a unique method for the finite element modeling and analysis of the torsion beam axle. The results of the FEA were verified using test data.

Bearing Strength of Hybrid Coupled Shear Wall Connections

  • Park Wan-Shin;Yun Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1065-1074
    • /
    • 2005
  • Due to lack of information, current design methods to calculate bearing strength of connections are tacit about cases in which hybrid coupled walls have connection details of stud bolts and horizontal ties. In this study, analytical study was carried out to develop model for calculating the connections strength of embedded steel section. The bearing stress at failure in the concrete below the embedded steel coupling beam section is related to the concrete compressive strength and the ratio of the width of the embedded steel coupling beam section to the thickness of the shear walls. Experiments were carried out to determine the factors influencing the bearing strength of the connection between steel coupling beam and reinforced concrete shear wall. The test variables included the reinforcement details that confer a ductile behavior in connection between steel coupling beam and shear wall, i. e., the auxiliary stud bolts attached to the steel beam flanges and the transverse ties at the top and the bottom steel beam flanges. In addition, additional test were conducted to verify the strength equations of the connection between steel coupling beam and reinforced concrete shear wall. The results of the proposed equations in this study are in good agreement with both our test results and other test data from the literature.

Experimental Study on the Effective Joint Width of the SRC Column-Steel Beam Joint (철골철근콘크리트 기둥-철골 보 접합부의 유효폭에 관한 실험적 연구)

  • 연선아;김승훈;서수연;이리형;홍원기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.405-410
    • /
    • 2001
  • To investigate factors influencing the effective width of. SRC column-steel beam joint resisting the moment as strut, six specimens are designed and tested. Parameters in the test are column width, beam height and horizontal tie within beam depth. From the test, using either wide column width or ties, strength and stiffness of joint were developed. The lower beam height the specimens showed the lower moment.

  • PDF

An Experimental Study on the Effect of Tie-wire on R/C Beam Behaviors (결속선이 R/C보의 거동에 미치는 영향에 대한 실험적 연구)

  • 변항룡;공귀옥;김준성;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.737-742
    • /
    • 1997
  • In this paper the effect of tie wire in lap spliced bars is investigated by experiment. The variables considered in the beam behaviors are beam dimension, lapped splice length and numbers of tie wire. 3 test pieces having the same variables consist one series and a total of 6 series ar tested. The test results show the beam behavior is not affected by numbers of tie wire but by the manner of tie. It was revealed hat the load bearing capacity of the beam is increased when the tie wire is extended to top bar.

  • PDF