• Title/Summary/Keyword: test System

Search Result 26,837, Processing Time 0.07 seconds

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Comparison of Radiologic Parameters between Weight Bearing Affected Both Ankle and Single Ankle in Ankle Exam (체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교)

  • Cha, Sangyoung;Shin, Jaehan;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.603-610
    • /
    • 2016
  • This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was $87.24^{\circ}$, TT was $6.44^{\circ}$, TMM was $26.76^{\circ}$, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was $88.93^{\circ}$, TT was $2.41^{\circ}$, TMM was $19.77^{\circ}$, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was $87.25^{\circ}$, TT was $5.71^{\circ}$, TMM was $23.92^{\circ}$, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was $3.19^{\circ}$, TMM $21.45^{\circ}$, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.

Video Assisted Thoracoscopic Sympathetic Ramus Clipping in Essential Hyperhidrosis -Cadaver Fitting Test and Clinical Application (다한증 환자에서 클립을 이용한 교감신경 교통가지 차단술 -사체 연구 및 임상적용-)

  • Lee, Sung-Ho;Cho, Seong-Joon;Jung, Jae-Seung;Kim, Tae-Sik;Son, Ho-Sung;Sun, Kyung;Kim, Kwang-Taik;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.595-601
    • /
    • 2003
  • Background: It has been known that the most effective treatment method of hyperhidrosis is video-assisted thoracoscopic sympathetic nerve block. Postoperative compensatory hyperhidrosis and anhidrosis are major factors that decrease the postoperative satisfaction. Although sympathetic rami have been selectively blocked to decrease the complications, technical difficulties and excessive bleeding have prevented the universal application. Material and Method: Three pre-fixative cadavers were dissected before clinical application. Bilateral sympathetic chains were exposed in supine position after the whole anterior chest wall was removed. Second and third sympathetic rami were blocked using clips. After the sympathetic chains including ganglia were removed, we evaluated the extents of rami block. Twenty-five patients were subjected to the clinical application. Surgeries were performed in semi-fowlers position under general anesthesia and bilateral ventilation. 2 mm thoracoscopy and 5 mm trocar were intro-duced through third and fourth intercostal space, respectively. Second and third sympathetic rami were blocked using thoracoscopic clips. The postoperative complications, satisfaction, and compensatory hyperhidrosis rate were evaluated retrospectively. Result: Sympathetic rami were completely blocked in cadaver dissection study Hyper-hidrosis symptom was improved in all patients without operative complication. Operative time was shorter than that of traditional ramicotomy. All patients, except four, were satisfied with postoperative palmar hyperhidrosis. Com-pensatory hyperhidrosis was more severely happened in fifteen patients (60%). The remaining six patients had no complaint. Two patients had a minimal degree of gustatory hyperhidrosis. Conclusion: This operative method had shorter operative time and less complication rate, compared with traditional ramicotomy Operative success rate was similar to the traditional syrnpathicotorny; lower extent and occurrence rate of compensatory hyperhidrosis. The thoracic sympathetic rami clipping was suggested as an alternative method for treatment of palmar hyperhidrosis.

Old Service Pipe Cleaning of Polly-pigs Cleaning technique (Polly-pigs를 이용한 노후급수관의 세관에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Park, Jeong-Hoon;Kim, Gil-Nam
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.303-312
    • /
    • 2002
  • Polly-pigs technique was developed to remove internal rusts and scales from service pipes in the building by using Polly-pigs that were used as various applications in conventional plant pipelines. Results of cleaning experiments on 15mm GSP(Galvanic Steel Pipe) showed that hydraulic cross sectional area was more increased from 3.5% to 15.4% for straight part or elbow parts of several test pieces. Results of optical analysis also showed that rust and scale removed mostly by KDP series(only consisted of Polyurethane) were outside red colored scale ($Fe_2O_3{\cdot}H_2O$), and there was a limitation to the removal of black colored scale($Fe_2O{\cdot}nH_2O$) that was below red colored scale. But it was evaluated that KDPS series coated fine sand with KDP series could remove not only red colored scale but also black colored scale and more increase hydraulic cross sectional areas of 15mm GSP old service pipes from 13.0% to 17.9%. After KDPS series cleaning, hydraulic cross sectional areas of them were recovered from 95.9% to 99.5%. Turning force of Polly-pigs was largely improved by the effect of Helical guide vane(Cleaning v/v) and Rotating wing(Pigs), and the number of pig rotating also more increased sixteen times compared with conventional cleaning system without Helical guide vane and Rotating wing. After KDPC series cleaning of 100mm GSP old service pipes that hydraulic cross sectional areas were 90%, hydraulic cross sectional areas were almost recovered perfectly like new service pipes. Additionally pressure necessary to run Polly-pigs m 100mm GSP was lower and cleaning efficiency also was higher than 15mm GSP cleaning. Therefore it was thought that as the diameter of pipe was more increased, pressure necessary to clean service pipes was more decreased and cleaning efficiency was more increased in Polly-pigs cleaning.

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

Survey of the Status of Conutry-of-origin Lables and Hygine on the Meat Markets of 4 Regions in Korea (4개 권역 축산물 판매업소의 원산지 표시실태 및 위생상태 표본조사)

  • Nam, Bo-Ra;Nam, Jung-Oak;Park, Jung-Min;Lee, Ra-Mi;Gu, Hyo-Jung;Kim, Myung-Hee;Chang, Un-Jae;Suh, Hyung-Joo;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2007
  • Expenditure on meat and meat products has been increased in Korea due to the increase of income and the change of diet. From raising farm animals to eating the meat, various hazardous elements can make their ways into the meat and meat products. Recently the issues on food safety and hygiene are drawing a lot of attention, and the current system for managing the safety of foods is still needed to be improved. This survey was aimed to monitor the current situation of country-of-origin labels and hygiene for the meat markets at 4 regions Korea. The survey was performed by collecting samples from whole- sale and retail stores in the nation, which were selling beef. The markets were divided into groups as to territory and the size of the market (Large size, Medium size, and Small size). In terms of size distribution, small butcher shops occupied the highest percentage. On the itemized suitability test of unpacked and packed beef, all the market of 4 regions showed good agreements. However, such labels indicating the methods of cooking and storage were not properly posted on the products. Especially for Ho-nam region, corrections are needed. The results of monitoring sanitation conditions for the butcher shops at 4 regions in Korea showed relatively low suitability. Especially, there were serious lack of knowledge about wearing the sanitation clothing, caps, and shoes. The problem with food safety is so complicated that producer, consumer, food manufacturer, the press, the government, and scholar should solve altogether. It is necessary to educate farmers, food handlers, consumers, etc. and provide them with an accurate information and knowledge.

Formaldehyde Exposure in the Plywood Manufacturing Factory (목재 가공업소에서의 Formaldehyde폭로)

  • Ha, Myung-Wha;Kim, Doo-Hie;Lim, Hyun-Sul;Park, Sang-Hu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.1 s.33
    • /
    • pp.37-44
    • /
    • 1991
  • In the plywood manufacturing factory established in 1979, female 3 workers who had exposed to adhesives containing formaldehyde for more than 48 months of duration suffered from eye, nasal, oral, throat and skin irritation and dyspnea as chief complaints. The actual level of the exposure to formaldehyde were not estimated when the exposed workers started to have above symptoms. The environmental monitoring of workplace was measured on April 25, 1990, and the concentration of formaldehyde revealed 0.2 ppm, however the exhaustive ventilatory system was already installed at that time. Twenty six subjects from entire factory were examined by questionnaire, physical examination and spirometry, etc. on August 22, 1990. Significant difference was observed in symptoms and signs of nasal, oral and throat irritation between the exposed group with longer duration and that with short duration. When the exposed group with longer duration was compared to the group of nonexposed, symptoms and signs of nasal, oral, throat and skin irritaion, chest tightness and dullness were significantly increased in the former group. The results of the spirometric test showed that the forced vital capacity and the forced expiratory volume at 1 second were decreased among the exposed group with longer duration but not significant.

  • PDF

Validity of Referral of High Risk Pregnancy in MCH Center (모자 보건 센터에서의 고위험 산모 의뢰 기준의 타당성)

  • Kim, Gui-Yeon;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.1 s.25
    • /
    • pp.146-152
    • /
    • 1989
  • To test the validity of referral of high risk pregnancy in the MCH Center, 6,017 pregnant women who visited MCH Center of South District Health Center for delivery between 1 April 1985 and 31 March 1987 were interviewed on arrival to obtain the data for demographic characteristics and obsteric history and traced to check the delivery outcome. Out of 5,820 women whose delivery outcomes were confrmed, 704 women(12.1%) were referred to other hospital or clinic for high risk factors. The proportion of poor delivery outcome(stillbirth, low birth weight and neonatal death) among referred cases was 4.4% while that of the women delivered at the MCH Center was 2.2% (p<0.01). Decision of the midwives for the referral of high risk pregnancy based on their clinical assessment was consistent with the delivery outcome (good or poor) in 86.5%. Major reasons for referral were premature rupture of membrane(46.5%) and cephalopelvic disproportion(20.0%) and the C-section rates for these cases were 10.1%, 17.6%, respectively. Discriminant analysis of the demographic characteristics and obstertric history for the discrimination of delivery outcome showed that gestational age had the highest discriminant function coefficient(0.88) and it was followed by parity(0.37) and maternal education(0.30). Referral of high risk pregnancy by the midwives based on their clinical assessment was considered to be reasonably valid. However, a risk scoring system for an MCH Center which can improve the validity may be developed if one applies the discriminant analysis for more comprehensive independent variable(including clinical assessment of midwife, demographic characteristics and obstetric history) and dependent variable (including medically indicated C-section, complication of pregnancy and delivery, stillbirth, low birth weight, neonatal death and maternal death).

  • PDF

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

A Study of the Utilization of Feldspathic Sand as a Fortified Functional Filtering Material for Water Purification (고 기능성 수질 정화 여과재로서의 장석질 모래 활용연구)

  • 고상모;송민섭;홍석정
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.283-293
    • /
    • 2003
  • Domestic water treatment plants operate the rapid and slow filtering system using the filtering sands. Most of them are composed of beach sands, which have less sorption capacity of heavy metals as well as organic contaminants. Therefore, the development of fortified functional filtering materials with high removal capacity of organic and inorganic contaminants is needed to prevent the unexpected load of contaminated source water. This study aims to test the hydrochemical change and the removing capacity of heavy metals such as Cd, Cu, and Pb on the Jumunjin sand, feldspathic sand(weathering product of Jecheon granite), feldspathic mixing sand I(feldspathic sand mixed with 10 wt% zeolite), and feldspathic mixing sand II (feldspathic sand mixed with 20 wt% zeolite). Feldspathic mixing sand I and II showed the eruption of higher amounts of cations and anions compared with the Jumunjin sand and feldspathic sand. They also showed higher eruption of Si, Ca, $SO_4$ ions than that of Al, $NO_3$, Fe, K, Mg, and P. Feldspathic mixing sand II caused higher eruption of some cations of Na, Ca, Al than feldspathic mixing sud I, which is the result controlled by the dissolution of zeolite. Jumunjin sand and feldspathic sand showed very weak sorption of Cd, Cu and Pb. In contrast to this, feldspathic mixing sand I and II showed the high sorption and removal capacity of the increasing order of Cd, Cu and Pb. Feldspathic mixing sand II including 20% zeolite showed a fortified removal capacity of some heavy metals. Therefore, feldspathic mixing sand mixed with some contents of zeolite could be used as the fortified filtering materials for the water filtering and purification in the domestic water treatment plants.