• Title/Summary/Keyword: tert-butyldimethylsilyl derivatives

검색결과 21건 처리시간 0.029초

Methylisothiocyanate를 이용한 아미노산 배열결정시 N(O)-butyldimethylsilyl 유도체로서의 methylthiohydantoin 아미노산의 기체 크로마토그래피에 의한 분석 (Gas-chromatographic determination of methylthiohydantoin amino acid as N(O)-butyldimethylsilyl derivatives in amino acid sequencing with methylisothiocyanate)

  • 우강융
    • Applied Biological Chemistry
    • /
    • 제35권2호
    • /
    • pp.132-138
    • /
    • 1992
  • Methylisothiocyanate에 의한 단백질의 아미노산 배열 결정시 순차적으로 분리되어 나오는 methylthiohydantion 아미노산을 기체 크로마토그라피로 효과적으로 정성 및 정량하기위하여 새로운 silylating reagent인 N-methyl-N-(tert.-butyldimethylsily)trifluoroacetamide를 사용하여 N-tert.-butyldimethylsily MTH 유도체로 silylation 한 후 HP-1 capillary column으로 분석하였다. Cystine을 제외한 21개의 단백질 구성 아미노산을 동정할 수 있었고 지금까지 packed column에서 TMS 유도체로 동정할 수 없었던 arginine도 분리 동정되었다. 2개 이상의 peak를 나타낸 것으로는 hydroxyproline, proline, isoleucine, glycine 및 tyrosine이었고 이중 hydroxyproline은 많은 수의 peak들로 분리되었다. Lysine, histidine 및 arginine은 주입량 $5.0\;nmole{\sim}15.0\;nmole$의 범위에서 나머지는 $2.5\;nmole{\sim}7.5\;nmole$의 범위에서 상관관계를 측정한 결과 고도의 직선 상관관계를 나타내었다(p<0.001). TMS 유도체에 의한 분석은 많은 불순 peak들 때문에 정량분석에 이용할 수 없었다.

  • PDF

Altered free amino acid levels in brain cortex tissues of mice with Alzheimer's disease as their N(O,S)-ethoxycarbonyl/tert-butyldimethylsilyl derivatives

  • Paik, Man-Jeong;Cho, In-Seon;Mook-Jung, In-Hee;Lee, Gwang;Kim, Kyoung-Rae
    • BMB Reports
    • /
    • 제41권1호
    • /
    • pp.23-28
    • /
    • 2008
  • The altered amino acid (AA) levels as neurotransmitter closely correlate to neurodegenerative conditions including Alzheimer's disease (AD). Target profiling analysis of nineteen AAs in brain cortex samples from three Tg2576 mice as AD model and three littermate mice as control model was achieved as their N(O,S)-ethoxycarbonyl/tert-butyldimethylsilyl derivatives by gas chromatography. Subsequently, star pattern recognition analysis was performed on the brain AA levels of AD mice after normalization to the corresponding control median values. As compared to control mice, $\gamma$-aminobutyric acid among ten AAs found in brain samples was significantly reduced (P < 0.01) while leucine was significantly elevated (P < 0.02) in AD mice. The normalized AA levels of the three AD mice were transformed into distorted star patterns which was different from the decagonal shape of control median. The present method allowed visual discrimination of the three AD mice from the controls based on the ten normalized AA levels.

지방산대사이상질환 스크리닝을 위한 TBDMS 유도체화 후 GC-MS를 이용한 혈장 중 유리지방산의 분석 (A Sensitive Determination of Plasma Free Fatty Acids Following Tert-butyldimethylsilyl Derivatization using Gas Chromatography-Mass Spectrometry for Screening of Fatty Acid Oxidation Disorders)

  • 윤혜란;타파마헤샬
    • 대한유전성대사질환학회지
    • /
    • 제17권2호
    • /
    • pp.39-47
    • /
    • 2017
  • Purpose: A sensitive gas chromatography mass spectrometry (GC-MS) method was developed for screening of fatty acid oxidation disorders. Methods: The assay utilized a simple protein precipitation with sulfosalicylic acid followed by tert-butyl dimethylsilyl (TBDMS) derivatization of hydroxyl functional group by N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Results: Calibration curves of spiked pooled plasma showed a linear relationship in the range of 0.01 ng -2 mg with correlation coefficient value greater than 0.98. Limits of detection (LOD) and limits of quantification (LOQ) were found in the range of 0.9-8.8 ng and 9-88 ng, respectively. Conclusion: The new developed method might be useful for a rapid, sensitive screening of inherited fatty acid oxidation disorders. In addition, the method expected to be one of the alternative method for screening newborns of metabolic disorders in the laboratories where expensive MS/MS is unavailable.

  • PDF

Simultaneous Determination of C22-C26 Very Long - Chain Fatty Acids Following tert-Butyldimethylsilyl Derivatization by Stable Isotope GC- MS for the Screening of Adrenoleucodystrophy

  • Yoon, Hye-Ran
    • Biomolecules & Therapeutics
    • /
    • 제15권4호
    • /
    • pp.266-272
    • /
    • 2007
  • A rapid analytical method was developed to quantify very long-chain fatty acids (VLCFAs, C22:0, C24:0, C26:0) in human plasma with good sensitivity and specificity using tert-butyldimethylsilyl (TBDMS) derivatization and stable isotope GC-MS selective ion monitoring (GC-MS/SIM). Two-hundred and fifty ${\mu}L$ of plasma was fortified with deuterated stable isotope internal standards (d3-C22:0, d3-C24:0, d3-C26:0) and standard mixtures of chloroform and methanol, and then extracted with hexane and acetonitrile. To upper layer of liquid-liquid-extraction, N-(t-Butyldimethylsilyl)-N-methyltrifluoroacetamide was added and then heated to $60^{\circ}C$ for 30 min to produce the TBDMS derivatives. Derivatives of VLCFAs were analyzed by GC-MS/SIM. Calibration curves showed a linear relationship for the target compounds in the concentration range of $10^{-4}{\sim}2{\times}10^3\;{\mu}g/mL$ with the correlation coefficient ranging from 0.996 to 0.999. The limit of quantification for the plasma was $10^{-4}{\sim}2{\times}10^{-4}\;{\mu}g/mL$ (S/N=3). When applied to the plasma specimens of patients with peroxisomal disorder, X-linked adrenoleucodystropy (ALD, Mckusick 202370), the method clearly differentiated normal subjects from ALD patients. The C24:0/C22:0 and C26:0/C22:0 ratios were significantly elevated in the plasma of patients with X-linked ALD compared to normal subjects. The new developed method might be useful for a rapid and sensitive diagnosis of X-linked ALD and other peroxisomal disorders.

Selective 3,4-Dihydroxyphenylalanine Analysis in Human Urine as Ethoxycarbonyltert-butyldimethylsilyl Derivatives by Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Cho, In-Seon;Shim, Woo-Young;Kim, Kyoung-Rae;Cho, Ki-Hong;Choi, Sang-Dun;Lee, Gwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.977-980
    • /
    • 2011
  • A new analytical method for measurement of 3,4-dihydroxyphenylalanine (DOPA) in human urine was developed. DOPA from an aqueous solution was converted into an ethoxycarbonyl (EOC) derivative. A tertbutyldimethylsilyl (TBDMS) reaction under anhydrous conditions was then attempted for analysis by gas chromatography-mass spectrometry in selected ion monitoring mode. A new mass spectral data on DOPA as a tri-EOC/mono-TBDMS derivative was built. This method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.1-9.2), and accuracy (% relative error = -7.2-8.8), with a detection limit of 0.05 ng/mL. This selective and accurate method of DOPA analysis will be useful for biochemical monitoring of various neurological disorders including Parkinson's disease in biological fluids.

Rapid Gas Chromatographic Profiling and Screening of Acidic Non-Steroidal Antiinflammatory Drugs in Biological Samples

  • Kim, Kyoung-Rae;Shin, You-Jin;Shim, Won-Hee;Myung, Seoung-Won
    • Archives of Pharmacal Research
    • /
    • 제17권3호
    • /
    • pp.175-181
    • /
    • 1994
  • The solid-phase extraction (SPF) with subsequent tert-butyldimethylsilyl (TBDMS) derivatization was investigated for the rapid profiling and screening of various carboxylated non-steroidal antiinflammatory drugs (NSAIDs) simultaneously in biological fluid samples. Compared to the conventional SPF in adsorption mode using Chromosorb 102, Chromosorb 107, Carbopak B and Thermosorb, the SPF in partition mode using Chromosorb P as the adsorbent, and ethyl acetate/methylene chloride as the eluting solvents provided hightest overall recovenies of the NSAIDs from aqueous solutions with good precision. The solid-phase extracted NASIDs were silylated with N-methyl-N-(tert-butyldimethylsily)trifuoroacetamide to TBDMS derivatives and directly analyzed by capillary gas chromatography and gs chromatography-mass spectrometry. The usefulness of the present method was examined for the profilling and screening of saliva, serum and urine samples for various NSAIDs simultaneously.

  • PDF

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Part-Per-Trillion level determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water

  • Kim, Hyub
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 추계국제학술대회
    • /
    • pp.149-149
    • /
    • 2003
  • A new technique is proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert.-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the GC/MS-SIM mode. The recoveries were 86.6∼105.2 % (isoBOC derivatization) and 97.6∼484.5 % (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol A for SIM were 0.001∼0.050 $\mu\textrm{g}$/l (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/l (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). The derivative methods and their application to tap water samples will be disscussed.

  • PDF

기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교 (Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM)

  • 김협;홍종기;김용화;김경례
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.196-213
    • /
    • 2002
  • 물 시료 중 알킬페놀류, 클로로페놀류 및 비스페놀 A의 동시분석을 기체크로마토그래피/질량분석기-선택이온검색법을 사용하여, US EPA 분석방법, isoBOC 유도체화 분석방법과 TBDMS 유도체화 분석방법을 비교하였다. 시료의 전처리는 유기용매로 추출하고 농축하여 분석한 방법과 XAD-4를 이용한 액체-고체 추출 후 isoBOC 유도체화와 TBDMS 유도체화를 실시하였다. 11종의 페놀류에 대한 회수율 실험은 3차 증류수에 각각 10 ${\mu}g/{\ell}$ (US EPA 방법) 또는 2 ${\mu}g/{\ell}$ (isoBOC 유도체화 분석방법과 TBDMS 유도체화 분석방법)의 농도를 대상으로 측정한 결과 각각 85.1~109.9%와 90.3~126.6%의 결과를 얻었다. 각 분석방법의 비스페놀 A에 대한 분석방법 검출한계는 US EPA 분석방법, isoBOC 유도체화 분석방법과 TBDMS 유도체화 분석방법이 각각 0.732 ${\mu}g/{\ell}$, 0.002 ${\mu}g/{\ell}$와 0.021 ${\mu}g/{\ell}$로 나타났으며, $5{\sim}400ng/{\ell}$의 농도 범위에서 isoBOC 유도체화 분석방법과 TBDMS 유도체화 분석방법 각각 0.9755~0.9981과 0.9908~0.9996의 직선성을 보였다. 폴리에틸렌 공장의 방류수를 대상으로 잔류량을 측정한 결과 일부페놀이 검출한계 이하에서 흔적으로 나타났다.

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • 제26권9호
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.