• Title/Summary/Keyword: terminal design simulation

Search Result 153, Processing Time 0.045 seconds

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

Improvement of Channel Efficiency in Mobile Communications by User Relay Scheme

  • JIA, Zhongning;MUTSUURA, Kouichi;AKIZUKI, Osamu;CHIN, YoonTze;HANDA, Shiro;OSHITA, Shinjiro
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1447-1450
    • /
    • 2002
  • In this paper, we propose a new access method named UR (Use. Relay) scheme to improve the channel efficiency in mobile communications. In UR scheme, packets of a data terminal that do not demand real time communications are relayed by other terminals during their inactive periods, which ue communicating with the base station through a fixed channel at that time. Simulation results show that with UR scheme, the blocking probability md the throughput are improved considerably with an allowable increase in the average delay.

  • PDF

1.8V Gilbert Cell CMOS Downconversion Mixer Using Bulk for 2.4GHz ISM band

  • Chae, Yong-Doo;Hwang, Young-Seung;Oh, Bum-Suk;Woong Jung
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.391-395
    • /
    • 2003
  • In this work, we have designed Gilbert cell downconversion mixer using 0.25um Anam CMOS process, we also have analyzed Conversion gain and IIP3 using Taylor series in our own unique way. Especially, bulk terminal is used as LO( Local Oscillator) input for reduction of power consumption and supply voltage. Supply voltage used in this design is lower than 1.8V and core current is less than 500uA. The simulation experiments showed that the conversion gain, IIP3, and power consumption were -1 dB, 4.46dBm, and 0.8mW, respectively.

  • PDF

The Forwarding Channel of a BTS in IS-95 CDMA Cellular Network

  • Kwag, Min-kok;Jung, Duk-in;Shin, In-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.990-994
    • /
    • 2000
  • The design of LAI(Local Area Identifier), the first paging area for searching the mobile terminal has a close relation with the performance of paging channel in CDMA cellular network. This paper discusses the performance of the forward channel of IS-95 CDMA standard, known as the paging through the related messages such as call control message, channel assignment message. Modeling and simulation work were conducted to quantify the performance of paging channel in terms of traffic handling capacity and blocking levels. This result serves as illustrative guidelines for the proper engineering of common control channel, which has a major impact on the overall performance of cellular network.

  • PDF

Identifying the Appropriate Position on the Ground Plane for MIMO Antennas Using Characteristic Mode Analysis

  • Won, Jusun;Jeon, Sinhyung;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.119-125
    • /
    • 2016
  • In this paper, a method for identifying the appropriate position on the ground plane for antennas is proposed based on the current correlation coefficient ($C^3$). This method explains that the mutual coupling between antennas when locating several antennas on the same ground plane is necessary. Given the current distribution on the ground plane induced by each antenna, easily estimating the coupling between antennas is possible. This paper also demonstrates that the proposed method can be used in the design of a multi-input multi-output system. The measured data are in good agreement with the simulation results.

Advanced Numerical Relaying for Power Transformer Protection (전력용변압기보호를 위한 개선된 수치계전기법)

  • Park, Chul-Won;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.217-219
    • /
    • 2004
  • The second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic-restrained RDR needs modification. This paper describes an advanced numerical algorithm that utilizes terminal voltage, differential current harmonics, harmonic ratio, and flux-differential current slope. Based on the results of testing with WatATP99 simulation data, the proposed algorithm was proven to be faster and more reliable.

  • PDF

Analysis of Harbor Responses due to the Dredging Work at Waterway and Mooring Basin in Busan New Port (부산 신항만에서 수로 및 박지 준설에 따른 항만정온도의 변화 분석)

  • Lee Joong-Woo;Lee Hak-Seung;Lee Hoon;Yang Sang-Yong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.97-104
    • /
    • 2006
  • Recently the first stage qf construction for Busan new port emerged over the sea surface at the north container terminal site. With this, there are lot of discussions and debates on increasing the water depth at the approaching channel and mooring basin from the existing 15m to 18m by dredging work in order to be able to serve 12,000TEU containership, and at the same time, correction to the reclamation plan of hinterland at the part of Undong Bay qf the new port site. Since the attack of typhoon 'Maemi' in 2003, it is expected that the design wave parameters for coastal and harbor structures in this area would be somewhat changed and so the extreme wave condition at each terminal and tranquility of berthing area does, and therefore, it is necessary to analyze the tranquility at each berth Hence in this study, we constructed a wave model for these conditions and performed simulation together with the circulation model simulation, compared with the field data collected The result showed the increase of the harbor response throughout the basin but not severe condition However, a certain location needs to be prepared for the rough sea condition when a severe typhoon hit the site.

Analysis of Harbor Responses due to the Dredging Work at Waterway and Mooring Basin in Busan New Port (부산 신항만에서 수로 및 박지 준설에 따른 항만정온도의 변화 분석)

  • Lee Joong-Woo;Lee Hak-Seung;Lee Hoon;Yang Sang-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.117-124
    • /
    • 2005
  • Recently the first stage of construction for Busan new port emerged over the sea surface at the north container terminal site. With this, there are lot of discussions and debates on increasing the water depth at the approaching channel and mooring basin from the existing 15m to 18m by dredging work in order to be able to serve 12,000TEU containership, and at the same time, correction to the reclamation plan of hinterland at the part of Undong Bay of the new port site. Since the attack of typhoon 'Maemi' in 2003, it is expected that the design wave parameters for coastal and harbor structures in this area would be somewhat changed and so the extreme wave condition at each terminal and tranquility of berthing area does, and therefore, it is necessary to analyze the tranquility at each berth. Hence in this study, we constructed a wave model for these conditions and performed simulation together with the circulation model simulation, compared with the field data collected. The result showed the increase of the harbor response throughout the basin but not severe condition. However, a certain location needs to be prepared for the rough sea condition when a severe typhoon hit the site.

  • PDF

A Remodeling Concept for the Underground Shopping Mall in Seoul - Focusing on the Linear Shopping Mall linked to Subway Lines - (지하상가 쇼핑환경 개선방향에 관한 연구 - 지하철과 연계된 직선형 지하상가를 중심으로 -)

  • Seo, Kyung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.15-23
    • /
    • 2010
  • First appeared in the 1970s, the underground shopping mall has been spreading across the country, and there reportedly exist 77 malls in the 2010. After over 30 decades operation, many underground shopping malls are now under the planning phase for renovation in many cities. This study considers the renovation issue of the underground shopping mall in the perspective of spatial re-configuration. A case is taken from Kangnam TerminalUnderground Shopping Mall in Seoul for detailed observation and suggestion. The monotonous and confusingspatial layout of the existing mall is investigated by observation methods. Based on the observation, a modifiedplan is suggested and evaluated by means of computer simulation program, Depth Map. The program mainly deals with visual network analysis in order to quantify the optical exposure in a given space. It is argued in this paper that the enhanced visual connectedness could affect the pedestrian performance positively in the shopping mall, and this leads to an easy and quick access to each shops in users' stand point. It is thought that this configurational solution for the remodelling of a specific case would be an effective reference for other malls in the country which are facing the similar problems.

Design of a Low-Power Parallel Multiplier Using Low-Swing Technique (저 전압 스윙 기술을 이용한 저 전력 병렬 곱셈기 설계)

  • Kim, Jeong-Beom
    • The KIPS Transactions:PartA
    • /
    • v.14A no.3 s.107
    • /
    • pp.147-150
    • /
    • 2007
  • This paper describes a new low-swing inverter for low power consumption. To reduce a power consumption, an output voltage swing is in the range from 0 to VDD-2VTH. This can be done by the inverter structure that allow a full swing or a swing on its input terminal without leakage current. Using this low-swing voltage technology, we proposed a low-power 16$\times$16 bit parallel multiplier. The proposed circuits are designed with Samsung 0.35$\mu$m standard CMOS process at a 3.3V supply voltage. The validity and effectiveness are verified through the HSPICE simulation.. Compared to the previous works, this circuit can reduce the power consumption rate of 17.3% and the power-delay product of 16.5%.