• Title/Summary/Keyword: tension ratio

Search Result 718, Processing Time 0.026 seconds

A novel method to specify pattern recognition of actuators for stress reduction based on Particle swarm optimization method

  • Fesharaki, Javad Jafari;Golabi, Sa'id
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.725-742
    • /
    • 2016
  • This paper is focused on stiffness ratio effect and a new method to specify the best pattern of piezoelectric patches placement around a hole in a plate under tension to reduce the stress concentration factor. To investigate the stiffness ratio effect, some different values greater and less than unity are considered. Then a python code is developed by using particle swarm optimization algorithm to specify the best locations of piezoelectric actuators around the hole for each stiffness ratio. The results show that, there is a line called "reference line" for each plate with a hole under tension, which can guide the location of actuator patches in plate to have the maximum stress concentration reduction. The reference line also specifies that actuators should be located horizontally or vertically. This reference line is located at an angle of about 65 degrees from the stress line in plate. Finally two experimental tests for two different locations of the patches with various voltages are carried out for validation of the results.

Effect of Si on Spatter Generation and Droplet Transfer Phenomena of MAG Wwlding (MAG 용접의 스패터 발생 및 용적이행현상에 미치는 Si의 영향)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • v.17 no.3
    • /
    • pp.36-43
    • /
    • 1999
  • The effect of Si content in welding wires on spattering characteristics and droplet transfer phenomena was studied. In MAG welding using 80% Ar-20% $CO_2$ shielding gas, spattering characteristics and droplet transfer phenomena were varied with Si content of wire. With increasing Si content, the spattering ratio and the ratio of large size spatter $(d\geq1.0mm)$ were increased. The increase of Si content in molten metal made surface tension increase due to reduction of oxygen content, which resulted from deoxidizing action of silicon. The increase of surface tension resulted in unstable transfer phenomena and arc instability in both short circuit and spray region. With changing Si content of wire, spattering characteristics and droplet transfer phenomena was directly influenced by the variation of surface tension, compared with the effect of arc stability.

  • PDF

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • v.4 no.5
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch (파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구)

  • Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

Post-yielding tension stiffening of reinforced concrete members using an image analysis method with a consideration of steel ratios

  • Lee, Jong-Han;Jung, Chi-Young;Woo, Tae-Ryeon;Cheung, Jin-Hwan
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.117-126
    • /
    • 2019
  • When designing reinforced concrete (RC) members, the rebar is assumed to resist all tensile forces, but the resistance of the concrete in the tension area is neglected. However, concrete can also resist tensile forces and increase the tensile stiffness of RC members, which is called the tension stiffening effect (TSE). Therefore, this study assessed the TSE, particularly after yielding of the steel bars and the effects of the steel ratio on the TSE. For this purpose, RC member specimens with steel ratios of 2.87%, 0.99%, and 0.59% were fabricated for uniaxial tensile tests. A vision-based non-contact measurement system was used to measure the behavior of the specimens. The cracks on the specimen at the stabilized cracking stage and the fracture stage were measured with the image analysis method. The results show that the number of cracks increases as the steel ratio increases. The reductions of the limit state and fracture strains were dependent on the ratio of the rebar. As the steel ratio decreased, the strain after yielding of the RC members significantly decreased. Therefore, the overall ductility of the RC member is reduced with decreasing steel ratio. The yielding plateau and ultimate load of the RC members obtained from the proposed equations showed very good agreement with those of the experiments. Finally, the image analysis method was possible to allow flexibility in expand the measurement points and targets to determine the strains and crack widths of the specimens.

Constitutive Law of Reinforced Concrete Subjected to Biaxial Tension (2축 인장을 받는 철근콘크리트의 구성방정식)

  • Cho, Jae-Yeol;Kim, Nam-Sik;Cho, Nam-So;Choun, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.69-77
    • /
    • 2003
  • One directional and biaxial tension tests of 13 reinforced concrete panels were conducted to derive a constitutive law of concrete. Based on the test results, a model equation is derived for the stress-strain relationship of concrete in tension. Main test variables are reinforcement ratio and the load ratio applied in two directions. In addition a failure envelope of concrete in tension-tension region is suggested based on the initial crack occurrence. Test results show that the concrete carries substantial tensile stress even after cracking occurrence. However, the application of this proposed stress-strain relationship for concrete is limited to the case where the direction of reinforcement coincides with the direction of the applied principal stresses.

Effects of Sulfonation Ratio in Petroleum Sulfonate Synthesis on Interfacial Properties and on Fluidity Properties of Cement Mortar (Petroleum Sulfonate의 합성에 있어서 황산화율이 계면활성 특성 및 시멘트 몰타르의 유동성에 미치는 영향)

  • Kim, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • In this study, the petroleum sulfonate(PS) was synthesized from pyolyzed fuel oil by sulfonation reaction with sulfuric acid. The PS synthesized had surfactant behaviors relating to the interfacial properties such as surface tension, surface adsorption, and wetting, etc. These interfacial properties were affected by the sulfonation ratio in the synthesis. As the sulfonation ratio increased, the surface tension of the PS aqueous solution decreased. However, when the ratio was too high, the surface tension was increased due to the extremely higher value of hydrophilicity of PS. At the optimum sulfonation ratio, the PS had a good wettability on the cement particles and a good fluidity of the cement mortar with a high adsorption.

Flexural behavior of reinforced lightweight concrete beams under reversed cyclic loading

  • Chien, Li-Kai;Kuo, Yi-Hao;Huang, Chung-Ho;Chen, How-Ji;Cheng, Ping-Hu
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.559-572
    • /
    • 2014
  • This paper presents the results of an experimental investigation on the flexural behavior of doubly reinforced lightweight concrete (R.L.C.) beams tested under cyclic loading. A total of 20 beam specimens were tested. Test results are presented in terms of ductility index, the degradation of strength and stiffness, and energy dissipation. The flexural properties of R.L.C. beam were compared to those of normal concrete (R.C.) beams. Test results show that R.L.C. beam with low and medium concrete strength (20, 40MPa) performed displacement ductility similar to the R.C. beam. The ductility can be improved by enhancing the concrete strength or decreasing the tension reinforcement ratio. Using lightweight aggregate in concrete is advantageous to the dynamic stiffness of R.L.C. beam. Enhancement of concrete strength and increase of reinforcement ratio will lead to increase of the stiffness degradation of beam. The energy dissipation of R.L.C beam, similar to R.C. beam, increase with the increase of tension reinforcement ratio. The energy dissipation of unit load cycle for smaller tension reinforcement ratio is relatively less than that of beam with higher reinforcement ratio.

Influence of Concrete Strength on Tension Stiffening (콘크리트강도가 인장증강에 미치는 영향에 관한 연구)

  • Yum, Hwan-Seok;Yun, Sung-Ho;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.1
    • /
    • pp.13-22
    • /
    • 2000
  • This paper describes the results obtained from 11 direct tension tests to explore the influence of concrete strength on tension stiffening behavior in reinforced concrete axial members. Three different concrete compressive strengths, 250, 650, and 900kgf/$\textrm{cm}^2$, were included as a main variable, while the ratio of cover thickness-to-rebar diameter was kept constant to be 2.62 to prevent from splitting cracking. As the results, it was appeared that, as higher concrete strength was used, less tension stiffening effect was resulted, and the residual deformation upon unloading was larger. In addition, the spacing between adjacent transverse cracks became smaller with higher concrete strength. The major cause for those results may be attributed to the fact that nonuniform bond stress concentration at both loaded ends and crack sections becomes severer as higher concrete is used, thereby local bond failure becomes more susceptible. From these findings, it would be said the increase in flexural stiffness resulting from using high-strength concrete will be much smaller than that predicted by the conventional knowledge. Finally, a factor accunting for concrete strength was introduced to take account for the effect of HSC on tension stiffening. This proposed equation predicts well the tension stiffening for the effect of HSC on tension stiffening. This proposed equation predicts well the tension stiffening behavior of these tests.

A Model Estimating the Ratigue Crack Growth in Aluminum Alloy A5083-O Considering the Effect of Stress ratio (응력비의 영향을 고려한 알루미늄합금 A5083-O의 피로균열전파 특성 예측모델)

  • 조상명;김종호;김영식
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.82-89
    • /
    • 1994
  • In this paper the effect of stress ratio on the fatigue crack growth rate of aluminum alloy A5083-O was examined. The fatigue tests were carried out using CCT (center cracked tension) specimens and CT(compact tension) specimens which were subjected to 0.5 and -1.0 stress ratio respectively. The obtained results are as follows; 1) The $\DeltaK_{th}$ as the function of stress ratio R was introduced in evaluating the fatigue crack growth rate of A5083-O. 2) A new model evaluating the effect of stress ratio on the fatigue crack growth rate was developed over the region of low and high propagation rate.

  • PDF