• 제목/요약/키워드: tension/movement control

검색결과 64건 처리시간 0.024초

한국후박(韓國厚朴)(Machili Cortex)의 소화기계(消化器系)에 대한 약효연구(藥效硏究) (Studies on theEfficacy of Machili Cortex in the Digestive System)

  • 이병주;정명현
    • 생약학회지
    • /
    • 제25권3호
    • /
    • pp.278-292
    • /
    • 1994
  • This study was attempted to investigate the effect of Machili Cortex extract(Machilus thunbergii Sieb. et Zucc. ) on digestive system in experimental animals. EtOH and MeOH extracts(E.E. and M.E.) were found to inhibit the charcoal transport rate in the small intestine of mice. E.E. exhibited the inhibition of spontaneous movement(motility) and tension in the ileum and colon strips of rabbit, and these actions were inhibited by action of acetylcholine. E.E. and M.E. given intraduodenaly(i.d.) exhibitied the significant decrease of gastric acid secretion in pylorus-ligated rats. E.E. and M.E. inhibited the formation of some experimental gastric ulcers(pylorus ligation-ulcer i.d., indomethacin-induced ulcer p.o. and aspirin-induced ulcer p.o. ) in rats, which are considered to relate to a protective action. E.E. and M.E. caused remarkable increase of bile excretion, compared with normal-control group, when adminstered through i.d., i.v. and p.o. The antibacterial activity against several intestinal microorganisms and other bacteria in vitro test was observed in the administration of E.E. and M.E.

  • PDF

백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현 (THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT)

  • 배성렬;김상철
    • 대한치과교정학회지
    • /
    • 제28권5호
    • /
    • pp.699-716
    • /
    • 1998
  • 본 연구는 열을 이용한 금속 브라켓의 재생 처리시, 기저부 형태와 브라켓 재생 방법에 따른 전단접착강도 및 브라켓 탈락 양상을 비교하고자 시행되었다. 교정 치료를 위해 발거된 건전한 소구치 252개를 수집하고, Type I, Type II, Type III 스탠다드 브라켓을 각각 재생 방법에 따라 네 군으로 나누어 준비된 소구치에 접착하고, Instron Universal Testing Machine(Model 4466)으로 전단접착강도를 측정하였으며, 브라켓의 탈락 양상을 관찰하고 브라켓 기저부의 주사전자현미경 소견을 관찰하였다. SPSS 통계처 리 프로그램을 이용하여 일원분산분석(oneway ANOVA), Scheffe's multiple range test를 실시하여 다음과 같은 결론을 얻었다. 1. 브라켓 기저부 형태에 따른 전단접착강도는 유의차가 있었으며(p<0.001), 그 크기는 Type III(round indentation, micro-etched base), Typ I(foil-mesh base), Type II(grooved integral base, micro-etched)의 순이었다. 2. 생 방법에 따른 전단접착강도는, Type I, Tpe II 브라켓에서는 Big Jane에 1분간 처리시 우수한 결과를 보였고 (p<0.05), Type III 브라켓에서는 각 군간 유의한 차이를 보이지 않았다(p>0.05). 3. Type I, Type II 브라켓은 기저부-레진 계면에서 가장 높은 빈도로 탈락하였고, Type III 브라켓에서는 레진의 절반 가량이 치면에 잔존하는 탈락 양상이 가장 많았다. 4. 탈락 양상에 따라 탈락시의 전단접착강도가 유의성 있는 차이를 보였는데(p<0.05),브라켓 탈락시 접착제의 절반 가량이 치면에 잔존하는 경우 전단접착강도가 가장 큰 것으로 나타났다. 5. 브라켓 재생 후 기저부에 남아 있는 접착제는 전단접착강도의 감소에 영향을 미치지 않았다.

  • PDF

엎드린 자세에서의 다리이음뼈 블록중재가 넙다리뒤근육 이완과 호흡시 엉치뼈 움직임에 미치는 영향 (The effect of prone pelvic blocking on hamstring muscle relaxation and sacral movement)

  • 차경수;김가은;정기훈;정승은;박순권;조일영
    • 디지털융복합연구
    • /
    • 제10권10호
    • /
    • pp.397-404
    • /
    • 2012
  • 엉치엉덩관절의 고정(sacroiliac joint fixation; SIJF)은 넙다리뒤근육의 과긴장을 일으키고, 호흡시 나타나는 엉치뼈의 움직임을 제한한다. 본 연구는 카이로프랙틱 기법 중 엎드린 자세에서 시술되어지는 S.O.T category I 골반 블록 중재가 SIJF를 완화시킬 수 있는지 알아보기 위한 것이다. 발꿈치긴장 검사를 통해 SIJF를 가진 26명의 참가자를 선정하여 실험군과 대조군에 각기 13명씩 무작위 할당하였다. 실험군은 category I 블록 중재를 받았고, 대조군은 거짓블록 중재를 받았다. 중재 전과 후에 넙다리뒤근육의 긴장 정도(체전굴 검사 이용)와 호흡시 엉치뼈의 움직임을 측정하였다. 발꿈치긴장 검사 결과 실험 군에 속한 참가자는 모두 음성반응을 보인 반면, 통제군의 참가자들은 양성반응을 보여 블록중재가 SIJF를 완화시킨 것을 확인하였다. 공분산분석(ANCOVA)에서 블록중재에 의해 체전굴 측정치[F(1, 23)=7.73, p<.05]와 호흡시 엉치뼈의 움직임[F(1, 23)=7.07, p<.05] 모두가 유의하게 증가된 것으로 나타났다. 그러나 통제군에서는 중재 전과 후의 차이가 없었다. 이 결과는 비침습적 중재법인 S.O.T category I 블록 기법이 SIJF와 관련된 증상을 완화시킬 수 있는 유용한 방법임을 시사한다.

Development of Real Time Monitoring and Forecasting/Emergency System for Land Slide of Road

  • Kim, Choon-Sik;Yoon, Soo-Ho;Shin, Seung-Mok;Hur Chul;Kim, Sang-Bong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.150.1-150
    • /
    • 2001
  • This paper introduces a real time inspecting and monitoring system by using wireless communication and image processing technique. The communication system is developed by using 80c196kc microprocessor and it has data acquisition function for several kinds of sensors such as pluviometer, temperature, tension meter, elinometer and so on. The image processing method adopts Lalacian of Gaussian operator and least square method to extract line features for the captured images and uses a relaxation matching algorithm based in global structure constraint satisfaction to distinguish the matching error for those features. When the algorithm is processed, motion parameters of displacement area and its direction are computed. Once movement is recognized ...

  • PDF

커넥팅로드 소단부 파단의 해석 (Failure Analysis of Connecting Rod at Small End)

  • 민동균;전병희;김낙수
    • 대한기계학회논문집
    • /
    • 제19권2호
    • /
    • pp.382-390
    • /
    • 1995
  • Failure of connecting rod in automotive engine may cause catastrophic situation. The corner radius at small end has an effect on stress raising. To investigate the stress distribution in connecting rod during operation, the finite element analysis was used by giving possible maximum tension and compression. Excessive sizing after forging connecting rod may result in the tensile residual stress which lower the fatigue life and cause premature failures. It was shown that when the sizing amount is too large, the location of high tensile residual stress coincide with that of high stress amplitude during operation through the elastic-plastic finite element analysis. The endurance limit moves down due to the surface finish and decarburization, which combines with the movement of resultant stress points to dangerous range. It was concluded that the precise control of sizing and enough corner radius are necessary to a reliability of connecting rod.

충격 흡수기의 동적거동 해석 프로그램을 이용한 각 파라미터가 댐핑력에 미치는 영향 조사 (An Investigation into the Effect of Each Parameter of S/A on the Damping Force Using Dynamic Behaviour Analysis P/G)

  • 박재우;신상윤;주동우;이시복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.371-376
    • /
    • 1996
  • The damping force of shock absorber in an automobile is determined by the components which construct the S/A. In this study we investigate the individual effect of these components on damping force. In addition, opening of important valve doling compression and tension cycle due to up-down reciprocation movement is also researched. Thus we are to strictly control the properties and tolerance of components having important effects on tile damping force and to produce S/A of better quality.

  • PDF

충격 흡수기의 동적거동 해석 프로그램을 이용한 각 파라미터가 감쇠력에 미치는 영향 조사 (An Investigation into the Effect of Each Parameter on the Damping Forces Using Dynamic Behaviour Analysis P/G of S/A)

  • Park, J.W.;Shin, S.Y.;Lee, S.B.
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.44-49
    • /
    • 1997
  • The damping force is determined by four valves and the components which consist of the shock absorber for vehicle. In this study it is investigated the individual effects of four valves and these components on damping forces using dynamic behaviour analysis program of the shock absorber. In addition, opening of main valves are researched during compression and tension cycle due to up- down reciprocation movement of piston. We are to strictly control the properties and tolerance of componenets having important effects on the damping force. Thus we are intended to produce shock absorber of better quality.

  • PDF

성견의 실험적 치아이동시 치주조직내 대식세포와 T-림파구의 활성에 관한 면역조직화학적 연구 (AN IMMUNOHISTOLOGIC STUDY ON THE ACTIVITY OF MACROPHAGE AND T-CELL IN THE PERIODONTIUM DURING TOOTH MOVEMENT OF DOG)

  • 박의웅;김상철;국윤아
    • 대한치과교정학회지
    • /
    • 제25권4호
    • /
    • pp.433-445
    • /
    • 1995
  • 교정력에 의한 성견의 치아이동시 발생하는 조직변화 중 염증과 면역반응에 중요한 역할을 하는 대식세포와 T-림파구의 치주조직내 활성도를 교정력의 크기와 기간에 따라 알아보고자 하였다. 생후 1년 6개월된 성견 6마리 중 5마리의 실험군과 1마리의 대조군이 연구되었는데 실험군에서 하악 좌측에는 강한 힘(250-300g)을, 하악 우측에는 약한 힘(50-75g)을 제1소구치와 제2소구치 사이에 open-coil spring으로 적용하였으며, 실험군의 성견을 각각 12시간, 24시간, 3일, 1주, 2주에 희생시켜 얻은 조직에 $\alpha$-1-antichymotiypsin과 CD3를 이용한 면역조직화학적 염색을 시행하였다. 결과적으로 염증세포침윤은 약한 힘을 준 경우보다 강한 힘을 준 경우에서 3일째까지 더 많이 나타나다가 7일이후에는 차이가 없어졌고 견인측보다는 압박측에서 많이 나타났으며, 압박측의 파골세포 활성은 12시간째에서부터 관찰되어 증가하다가 7일째부터 감소되었는데 약한 힘을 준 경우에서보다 강한 힘을 준 경우에서 더 많이 나타났다. 견인측 치주인대의 단절과 혈관확장은 12시간째 관찰되어 증가하다가 3일째 이후에는 감소되었는데 약한 힘을 준 경우보다는 강한 힘을 준 경우에서 더 많았으나 14일째에는 차이가 없었다. 대조군의 $\alpha$-1-antichymotiypsin발현은 열구상피에서 주로 발현되었고 치주인대, 치수, 골세포에서는 음성반응을 보였으며, 실험군의 $\alpha$-1-antichymotiypsin발현은 견인측보다 압박측에서 많았으며, 3일째까지는 치경부쪽이 약간 많았고, 7일째 이후에는 주로 치경부보다는 치근단쪽에서 더 많이 발현되었다. 약한 힘을 준 경우는 $\alpha$-1-antichymotiypsin 염색이 12시간째부터 나타나서 7일째에 가장 많이 나타나다가 이후 감소되었고, 강한 힘을 준 경우에서는 3일째에서 최고에 달하다가 이후에는 감소되었다. 약한 힘을 준 경우나 강한 힘을 준 경우 모두에서 CD3에 대한 발색은 전치주조직을 통해 거의 음성으로 나타났다.

  • PDF

성견의 실험적 치아이동시 골재형성에 관한 연X선학적 연구 (A SOFT X-RAY STUDY ON THE BONE REMODELLING IN TOOTH MOVEMENT OF DOG)

  • 김상철
    • 대한치과교정학회지
    • /
    • 제25권5호
    • /
    • pp.587-592
    • /
    • 1995
  • 교정력에 의한 치아이동시 발생하는 골침착과 흡수의 골재형성 과정을 교정력의 크기와 적용기간에 따라 비교해 보고자 하였다. 성견 6마리를 대조군 1마리와 실험군 5마리로 나누어 실험군에서는 하악 제 1,2소구치 사이에 open coil spring을 장착해서 좌측에는 강한 힘(250-300g), 우측에는 약한 힘(50-75g)이 가해지도록 하여 12시간, 24시간, 3일, 1주, 2주에 각각 희생시켰다. 분리된 조직편에 대해 연X선 촬영을 하여 분석한 결과 다음과 같은 결과를 얻었다. 1. 견인측에서의 신생골 형성은 7일째부터 관찰되기 시작하여 14일째에는 광범위한 부위에서 방사선 불투과상을 관찰할 수 있었으나 힘의 크기에 따른 비교는 불가능하였다. 2. 압박측에서의 치조골 흡수는 3일째에 치조백선의 파괴로 나타나기 시작하여 7일째, 14일째에 걸쳐 증가되는 양상을 보였다.

  • PDF

고속카메라를 이용한 Drop-on-demand 방식의 정전 액적 토출 분석 (Analysis of Electrostatic Ejection of Liquid Droplets in Manner of Drop-on-demand Using High-speed Camera)

  • 김용재;최재용;손상욱;김영민;이석한;변도영;고한서
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.128-133
    • /
    • 2007
  • An electrostatic inkjet head can be used for manufacturing processes of large display systems and printed circuit boards (PCB) as well as inkjet printers because an electrostatic field provides an external force which can be manipulated to control sizes of droplets. The existing printing methods such as thermal bubble and piezo inkjet heads have shown difficulties to control the ejection of the droplets for printing applications. Thus, the new inkjet head has been proposed using the electrostatic force. A numerical analysis has been performed to calculate the intensity of the electrostatic field using the Maxwell's equation. Also, experiments have been carried out to investigate the droplet movement using a downward capillary with outside diameter of $500{\mu}m$. Gravity, surface tension, and electrostatic force have been analyzed with high voltages for a drop-on-demand ejection. It has been observed that the droplet size decreases and the frequency of the droplet formation and the velocity of the droplet ejection increase with increasing the intensity of the electrostatic field using high-speed camera.

  • PDF