• Title/Summary/Keyword: tensile damage

Search Result 682, Processing Time 0.023 seconds

Bend Resistance of Polymer Cement Slurry Coated Reinforcing Bars

  • Kim, Wan-Ki;Chang, Sung-Ju;Kim, Hyun-Ki;Soh, Yang-Seob
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.42-48
    • /
    • 2001
  • The bend resistance of coated reinforcing bar is greatly influenced by both the adhesion strength between bar and coating materials, and the followed transformation of coating material as bars bend. Especially, tearing state or partial microscopic cracks are predicted on the inside and outside of bending angle, because tensile strength and elongation of polymer film are very different according to types of polymer dispersions in bar coating, and these damaged parts are rapidly corroded by penetration of corrosive factors. In this study, polymer cement slurry coated reinforcing bars with various polymer dispersions are prepared by following combined conditions, polymer-cement ratio of 50% and 100%, coating thickness of 250$\mu$m and 450$\mu$m, coating number, curing age of 3, 7, 14 and 28days. Then the specimens are tested for working life and bend resistance at bending angles $90^{\circ}$, $135^{\circ}$and $180^{\circ}$ to observe the microscopic damage effect as the bars bend. Also, epoxy-coated reinforcing bars for control experiment were used with 250$\mu$m of coating thickness. The tensile strength for polymer films is performed. From the test results, the working life of the polymer cement slurry is within 90 seconds. Among four types of polymer dispersion, polymer cement slurry coated reinforcing bar using St/BA-1 emulsion has the excellent bend resistance, which is remarkably improved than that of epoxy-coated reinforcing bar. And the bend resistance is more related to elongation than tensile strength of polymer film. Polymer cement slurry with a polymer-cement ratio of 100%, a coating thickness of $450\mu$m and one coating using St/BA emulsion is selected as a most suitable coating material for coated reinforcing bar.

  • PDF

Study on Fastened Properties by Applied to CFRP Laminates of Subminiature Screw (초소형나사의 CFRP 적층판 적용에 따른 체결특성에 관한 연구)

  • Choi, Byung Hui;Kim, Ho Joong;Kim, Ji Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1239-1243
    • /
    • 2014
  • This paper presents the application of carbon-fiber-reinforced polymer (CFRP) for the damage absorption and optimal design of portable smart devices to close in life. CFRP specimens are subjected to a tensile test to estimate their mechanical properties in terms of the stacking angles. Further, the screw reverse torque and screw torque at each stacking angle are determined using a torque tester after tapping holes on the CFRP specimens. Two experiments are performed for comparing their results in order to determine optimal conditions. In the tensile test, a woven specimen is found to have the highest strength and stiffness. In the case of the woven specimen, no difference is observed even when it is applied to prevent loosening of the coating. And average result value was excellent.

Hair-dyeing by using Pomegranate Hull Extract (석류 과피 추출물을 이용한 모발염색)

  • Cho, A-Rang;Shin, Youn-Sook;Yoo, Dong-Il
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.42-50
    • /
    • 2008
  • The objective of this study is to investigate the efficacy of pomegranate hull colorant as a natural hair coloring dye. The extract of pomegranate hull was concentrated and freeze-dried to get colorant powder. Effect of dyeing condition and mordanting on the dye uptake of hair by using Al, Fe, Cu, Cr, Sn compounds, color change and colorfastness were explored. In addition, tensile strength was measured and the surface of the hair was observed. Dye uptake of hair measured by K/S value (400 nm) indicated that ionic bonding seems to be involved in the sorption of pomegranate colorant to hair. Maximum sorption was obtained at pH 3.5 and the concentration of 50% (on the weight of hair, o.w.h.). Acidic dyeing condition (pH $3.5{\sim}5.0$) showed yellow color however alkaline dyeing condition (pH $7{\sim}11$) gave reddish yellow color. Pomegranate hull colorant produced greyish brown color on hair and the hair mordanted with Fe showed dark brown color. Mordants except Fe did not increase dye uptake significantly. Mordants except Cu increased light fastness and mordants except Cr increased washing fastness level slightly. According to SEM observation and the tensile strength retention measurement, the mordant dyed hair gave more damage to hair by ultraviolet light and washing than the hair dyed without mordanting. Experimental results of K/S value and colorfastness(light and washing) supported that pomegranate hull colorant without mordanting can be used as a semi-permanent natural hair coloring dye.

Nondestructive Evaluation of Fatigue Damage (피로손상과 비파괴평가)

  • Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • In order to determine the mode I stress intensity factor ($K_I$) by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a paramagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effects of the magnetic flux and the demagnetization on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. The change in potential drop was linearly decreased with increasing the tensile load and was caused by the change in conductivity near the crack tip. The reason of decreasing the change in potential drop with increasing the tensile load was that the increase of the conductivity near the crack tip due to the tensile load caused the decreases of the resistance and internal inductance of the specimen. The relationship between the change in potential drop and the change in $K_I$ was not affected by demagnetization and was independent of the crack length.

  • PDF

Mechanical Strength Evaluation of A53B Carbon Steel Subjected to High Temperature Hydrogen Attack

  • Kim, Maan-Won;Lee, Joon-Won;Yoon, Kee-Bong;Park, Jai-Hak
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2007
  • In this study mechanical strength of A53B carbon steel was analyzed using several types of test specimens directly machined from oil recycling pipe experienced a failure due to hydrogen attack in chemical plants. High temperature hydrogen attack (HTHA) is the damage process of grain boundary facets due to a chemical reaction of carbides with hydrogen, thus forming cavities with high pressure methane gas. Driven by the methane gas pressure, the cavities grow on grain boundaries forming intergranular micro cracks. Microscopic optical examination, tensile test, Charpy impact test, hardness measurement, and small punch (SP) test were performed. Carbon content of the hydrogen attacked specimens was dramatically reduced compared with that of standard specification of A53B. Traces of decarburization and micro-cracks were observed by optical and scanning electron microscopy. Charpy impact energy in hydrogen attacked part of the pipe exhibited very low values due to the decarburization and micro fissure formation by HTHA, on the other hand, data tested from the sound part of the pipe showed high and scattered impact energy. Maximum reaction forces and ductility in SP test were decreased at hydrogen attacked part of the pipe compared with sound part of the pipe. Finite element analyses for SP test were performed to estimate tensile properties for untested part of the pipe in tensile test. And fracture toughness was calculated using an equivalent strain concept with SP test and finite element analysis results.

Effect of high concentrations of carboxymethyl chitosan on preventing formation of peritoneal adhesion in rats (랫드에서 고농도의 Carboxymethyl Chitosan이 복벽 유착 예방에 미치는 영향)

  • Kwon, Young-Sam;Jang, Hwan-Soo;Jeong, Jae-Hoon;Bae, Jae-Sung;Rhee, Jeong-Woo;Kang, Han-Saem;Yang, Jeong-Hoon;Li, Wen-Xue;Jang, Kwang-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.1
    • /
    • pp.151-156
    • /
    • 2003
  • The objective of this study was to determine the effective concentration of carboxymethyl chitoaan(CMC) solution on preventing intraperitoneal adhesions. In this study, 60 rats were divided into four groups : an untreated control group and three experimental groups that were treated with 3 ml of 3, 5, and 7% CMC solution. Adhesions were induced by suturing both the ileal serosa and peritoneum scraped until petechial bleeding occurred. CMC solutions were instilled intraperitoneally immediately before closure of the peritoneomuscular layer. The tensile strength of formed adhesions was measured by using a computerized tensiometer. Histopathological changes of adhesions were evaluated by hematoxylin-eosin for light microscopic examination and Massons's trichrom staining for collagen fibers. All of CMC solutions reduced significantly the tensile strength of the adhesions. CMC inhibited the increase of inflammatory cell infiltration and damage of adhesion spot, and accelerated the collagen synthesis and neovascuiarization. No significant differences were observed among all of CMC concentration at inhibiting adhesion formation. Therefore, we could conclude that 3% CMC, the lowest concentration adopted in this study, was appropriate to prevent the formation of peritoneal adhesion.

Development and Performance Test for Unbonded Post-Tensioned Anchor (비부착 강연선에 대한 포스트텐션 정착구 개발 및 성능 시험)

  • Cho, Ah Sir;Jo, Yeong Wook;Jeon, Byong Kap;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2015
  • An unbonded post-tensioned anchor using a 15.2 mm diameter 7-wire strand was developed based on finite element analysis and experimental testing. In order to evaluate its performance, static load tests and load transfer tests were conducted following KCI-PS101. The static load tests and additional strand tensile tests confirmed that the developed anchor had a capacity more than nominal tensile strength of a 7-wire strand without any damage or deterioration. According to the result of load transfer tests for many different reinforcing details, specimens with no additional reinforcing bars sustained at least 1.64 times the nominal tensile strength of the strand.

A Parametric Study on Tensile Stress of a Hybrid Floating Structure System (매개변수 연구를 통한 하이브리드형 부유식 구조물의 인장응력 발생 분석)

  • Zi, Goangseup;Lee, Seung-Jung;Kwak, Yeon-Min;Jeong, Youn
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.313-320
    • /
    • 2012
  • A hybrid floating structure system combined with pontoon and semi-submersible type modules is proposed. This new system can reduce tensile forces of bottom slabs which could cause fatal damage of concrete floating structures. We performed a parametric study on the dimensions of this new system and investigate the sensitivity of the parameters to the behavior. In order to investigate various cases efficiently, we developed a simple two-step static analysis method for the fluid-structure interaction. An optimum system is derived from the investigation of the analysis results, weights and drafts of the hybrid structure. This study shows that introducing this new system to concrete floating structures is an effective way to reduce the tensile force of the bottm slab of such a floating structure. Also, it was found that when the length of the semi-submersible module is about 15%, the behavior would be optimal in the considered case.

A model of fatigue crack growth based on plastic stretch at the crack tip (균열선단의 소성스트레치를 이용한 피로균열성장모델)

  • Ju, Yeong Sik;Kim, Jae Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.15-22
    • /
    • 2003
  • The fatigue crack growth model is derived and the retardation model is proposed. The fatigue crack growth model considers the residual plastic stretch on the crack surface which results from the plastic deformation at the tip of fatigue crack. The fatigue crack growth rate is calculated by using the cumulative fatigue damage and plastic strain energy in the material elements at the crack tip. This model gives the crack growth rate in reasonable agreement with test data for aluminum alloy AL6061-T651 and 17-4PH casting steel. The fatigue crack growth retardation model is based on the residual plastic stretch produced from a tensile overload which reduced the plastic strain range of the following load cycles. A strip-yield model of a crack tip plasticity is used for the calculation of a plastic zone size. The proposed retardation model characterized the observed features and delayed retardation of the fatigue crack growth under tensile overload.

Evaluation of the Weak Part for Wave Dissipating Blocks under Various Conditions: Tetrapod (다양한 하중 조건에서 Tetrapod 소파블록의 취약부 분석)

  • Lim, Jeong Hyeon;Won, Deokhee;Han, Taek Hee;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5385-5392
    • /
    • 2014
  • Super typhoons develop as a result of meteorological changes. In 2012, Typhoons Bolaven and Denba reached Korea. The maximum instantaneous wind speed of the typhoons reached 60 m/sec. Harbor structures including sofa block sustained damage and loss by the abnormally high waves. In Korea, tetrapod blocks were installed the most for wave dissipating. Nevertheless, a structural evaluation of the tetrapod block has not been performed. This study examined the structural mechanism and weakness part of the tetrapod block under a range of boundary conditions. The block has weakness against a tensile force because it is plain concrete. The joint part of the legs is the most vulnerable to tensile stress. The weakest part can be reduced if the joint part is reinforced as a hunch.