• Title/Summary/Keyword: temporal pattern of design rainfall

Search Result 17, Processing Time 0.028 seconds

An Analysis on Hydrologic Characteristics of Design Rainfall for the Design of Hydraulic Structure (수공구조물 설계를 위한 설계강우의 수문학적 특성 분석)

  • Lee, Jeong-Sik;Lee, Jae-Jun;Park, Jong-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.1
    • /
    • pp.67-80
    • /
    • 2001
  • This study is to propose temporal pattern of design rainfall which causes maximum peak discharge and to analyze the variation in peak discharge according to design rainfall durations. In this study, the Mononobe, the Yen and Chow triangular, the Huff's 4th quartiles and the Keifer and Chu methods are applied to estimate the proper temporal pattern of design rainfall and three rainfall-runoff models such as SCS, Nakayasu, and Clark methods are used to estimate the runoff hydrograph. And to examine the variability of peak discharge, the hydrologic characteristics from the rainfall-runoff models to which uniform rainfall intensity is applied are used as the standard values. The type of temporal pattern of design rainfall which causes maximum peak discharge in both of the watersheds and the rainfall-runoff models has resulted in Yen and Chow distribution method with the dimensionless vague of 0.75. On the basis of determined temporal pattern, the examination of the variability of peak discharge according to design rainfall durations shows that design rainfall duration varies greatly with the types of probable intensity formula, and the variation of peak discharge is more affected by the types of probable intensity formula and I-D-F currie than rainfall-runoff models.

  • PDF

Identification of Factors Affecting the Occurrence of Temporal Patterns of Rainfall in Gamcheon Watershed (감천유역에 대한 강우양상 발생 영향인자의 규명 및 해석)

  • Ahn, Ki-Hong;Cho, Wan-Hee;Han, Kun-Yeun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • In South Korea, seasonal, local and temporal climatic characteristics are variable in rainfall patterns. To design or assess the reliability of hydrosystem, information about the rainfall event under consideration is important. In this process, the complete description of a design storm involves the specification of rainfall duration, depth, and its temporal pattern. Generally, to use an appropriate temporal pattern for a design storm is of great importance in the design and evaluation of hydrological safety for hydrosystem. For purpose of selecting of factors affecting the occurrence of rainfall patterns, Huff's dimensionless method was executed and examined by statistical contingency tables analysis through which the inter-dependence of the occurrence frequency of rainfall patterns with respect to geographical location, rainfall duration and depth, and seasonality is investigated. This analysis result can be used to establish flood policies and to design or assess the reliability of hydrosystem.

An Analysis of Runoff Reduction Effect of Infiltration Facilities in Urban Area (도시유역에서 침투시설의 우수유출저감효과 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae;Lee, Sang-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.628-631
    • /
    • 2007
  • One of the structural measures for the peak flow reduction is infiltration facilities. There are many types in infiltration facilities - infiltration basin, trench, bed, porous pavement, percolated subdrain, dry well. In this study runoff reduction effect of infiltration trench is analyzed by WinSLAMM. Runoff reduction effect is investigated by each design rainfall and temporal pattern of rainfall particularly. The biggest reduction is shown in Yen and Chow's temporal pattern of design rainfall and the smallest reduction is shown in Huff's first quartile pattern. Runoff reduction rate is presented about 6 to 14 percentage, and the larger return period, the smaller runoff reduction rate.

  • PDF

Design of Detention Pond and Critical Duration of Design Rainfall in Seoul

  • Lee, Jong-Tae;Yoon, Sei-Eui;Lee, Jae-Joon
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.33-43
    • /
    • 1994
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribytion of the design rainfall, Huff's quartile method is used for the 9 cases of durations (ranges from 20 to 240 minutes) with ten years return period, and the ILLUDAS model is used for runoff analysis. The storage ratio, which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the criticalduration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watercheds with pump station in Seoul, of which the range of watershed area is 0.24~12.70$km^2$. The result of simulation shows that the duration which maximizes storage ratio is 30 and 60 minutes on the whole. It is also shown that the storage ratios of 2nd - and 3rd-quartile pattern are larger than those of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by the regression analysis between the maximum storage ratio and the peak ratio. This formula can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

Comparative Study on Calculation Method for Design Flood Discharge of Dam (댐 설계홍수량 산정방법에 관한 비교연구)

  • Lee, Jai-Hong;Lee, Jong-Kyu;Kim, Tae-Woong;Kang, Ji-Ye
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.941-954
    • /
    • 2011
  • In this study, past method and recent method for flood discharge with domestic multi-purpose dams in Korea were compared and analyzed with respect to the scale of watershed. Rainfall depth, temporal pattern, rainfall excess, rainfall-runoff model, parameter estimation and base flow were selected as the principal factors affecting flood discharge and effects on flood discharge were analyzed quantitatively by using sensitivity analysis. The results showed that the flood discharges calculated by past and recent method increased and decreased with a wide range of discharge with respect to the scale of watershed. The reason for decrease of flood discharge is the exchange of temporal pattern of rainfall and the principal reasons for increase of flood discharge are the increase of rainfall depth by unusual weather phenomena and the difference of estimation method for parameters of unit hydrograph.

A Study on the Critical Duration of Design Rainfall in Midsize Catchment (중규모 하천유역에서 설계강우의 임계지속기간에 관한 연구)

  • Park, Jong-Young;Shin, Chang-Dong;Lee, Jung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.9
    • /
    • pp.695-706
    • /
    • 2004
  • This study is to propose the temporal pattern of design rainfall which causes maximum peak discharge, and to analyze the relation of catchment characteristics and critical durations for gauged midsize catchment. Hydrologic analysis has done over the 44 midsize catchments with 50-5,000$\textrm{km}^2$. The type of temporal pattern of design rainfall which causes maximum peak discharge has resulted in Huff's 4 quartile distribution method for effective rainfall(AMC III) The peak discharges of 24hr rainfall duration are similar to those of critical duration for 50-600$\textrm{km}^2$, and the peak discharges of 48hr rainfall duration are similar to those of critical duration for 600-5,000$\textrm{km}^2$. Therefore, if the proper rainfall intensity formula is selected, 24hr or 48hr rainfall duration may be regarded as the critical duration of midsize catchment. A simple regression equation is derived by using a catchment area and critical duration with high correlation for the case of effective rainfall(AMC III). Therefore, it can be used to determine the critical duration of ungauged catchment with 50-5,000$\textrm{km}^2$. Also, dimensionless regression equation is derived by using characteristic values of unit hydrograph.

Critical Duration of Design Rainfall for the Design of Storm Sewer in Seoul (우수관거 설계를 위한 계획강우의 임계지속기간 -서울 지역을 중심으로-)

  • 이재준;이정식;전병호;이종태
    • Water for future
    • /
    • v.26 no.2
    • /
    • pp.49-57
    • /
    • 1993
  • A hydrological method is performed to determine the critical duration of design rainfall for the design of storm sewer in Seoul. To seize the effect of the duration and the temporal distribution of the rainfall to the peak discharge of the storm sewer, the Huff's quartile method is used as a temporal pattern for the design rainfall of any durations (9 cases for 20-240 min.) with 10 years return period. The critical duration of design rainfall is determined as the duration which maximizes the peak discharge. This study is applied to 18 urban drainage systems in Seoul. The ILLUDAS model is applied to runoff analysis, and the result shows that the duration which maximizes peak discharge is 30, 60 minutes generally. The relation diagram between peak discharge for the critical duration and watershed area is prepared for the design of storm sewer.

  • PDF

The Analysis of Critical Duration of uncontrolled single detention facility in Small Catchment (소규모 유역에서 자연방류형 단일저류지의 임계지속기간 분석)

  • Park, Jong-Young;Shin, Chang-Dong;Lee, Jung-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.2 s.17
    • /
    • pp.17-28
    • /
    • 2005
  • The objective of this study is to evaluate the critical duration between detention facility and flood control facility of small size catchment. 4 small size catchments are applied for hydrological analysis and rainfall excess is computed by using the NRCS Runoff Curve Number method. The critical duration of detention facility and flood control facility is evaluated using the concept of allowable release rate. The conclusions studied in this study are as follows; (1) The type of temporal pattern of design rainfall which causes maximum storage ratio has resulted in Huff's 2 quartile in case of the use of the concept of allowable release rate. (2) Based on (1) of conclusion, the critical durations of flood control facility are similar to those of detention facility, which is used for uncontrolled single detention pond.

Study on the Calculation Method of Design Flood Discharge of Dam (댐 설계홍수량 산정방법에 관한 연구)

  • Lee, Jai-Hong;Moon, Young-Il;Beck, Yoo-Hyun;Jang, Kwang-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.277-281
    • /
    • 2011
  • In this study, past method and recent method for flood discharge with domestic multi-purpose dams in Korea were compared and analyzed with respect to the scale of watershed. Rainfall depth, temporal distribution, effective rainfall, rainfall-runoff model, parameter estimation and base flow were selected as the principal factors affecting flood discharge and effects on flood discharge were analyzed quantitatively by using sensitivity analysis. The results showed that the flood discharges calculated by past and recent method increased and decreased with a wide range of discharge with respect to the scale of watershed. The reason for decrease of flood discharge is the exchange of temporal distribution pattern of rainfall and the principal reason for increase of flood discharge are the increase of rainfall depth by unusual weather phenomena and the difference of estimation method of parameters of unit hydrograph.

  • PDF

Design of Edtention Pond and Critical Duration of Design Rainfall in Seoul (유수지 설계를 위한 계획강우의 임계지속기간 -서울 지역을 중심으로-)

  • 이종태;윤세의
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.115-124
    • /
    • 1993
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribution of the design rainfall, Huff's quartile method is used for the 9 cases of durations ranging from 20 to 240 minutes with 10 years return period, and the ILLUDAS model is used for runoff analysis. The storage ration which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the critical duration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watersheds with pump station in Seoul, of which the range of watershed area is $0.24-12.70\textrm{km}^2.$ The result of simulation shows that the duration which maximizes storage ration is 30 and 60 minutes on the whole. It is shown also that the storage ration of 2nd- and 3rd-quartile pattern is larger than that of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by using the regression analysis between the maximum storage ration and the peak ratio, and can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF