• Title/Summary/Keyword: temperature-shift

검색결과 921건 처리시간 0.025초

일산화탄소 저감을 위한 개질가스의 전이반응 연구 (Investigation of the Water Gas Shift from Reforming Gas for CO Removal)

  • 김성천;윤문중;전영남
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.855-859
    • /
    • 2007
  • Hydrogen as an energy carrier in fuel cell offers perhaps the largest potential benefits of reduced emissions of pollutants and greenhouse gases. The generation of high-purity hydrogen from hydrocarbon fuels is essential for efficient operation of fuel cell. Reduction of carbon monoxide to an acceptable level of 10ppm involves high temperature and low temperature water gas shift (WGS), followed by selective oxidation of residual carbon monoxide. The WGS reactor was designed and tested in this study to produce hydrogen-rich gas with CO to less than 5000 ppm. In the water gas shift operation, gas emerges from the reformer is taken through a high temperature shift (HTS) catalyst to reduce the CO concentration to about $2{\sim}4%$ followed to about 5000 ppm via a low temperature shift (LTS) catalyst.

RPF(Refuse plastic fuel) 합성가스의 수성가스 전환 반응 연구 (A Study on the Water Gas Shift Reaction of RPF Syngas)

  • 노선아
    • 자원리싸이클링
    • /
    • 제30권6호
    • /
    • pp.12-18
    • /
    • 2021
  • 수성가스 전환 반응은 가스화로 생성된 합성 가스에 수소 생산 증가와 H2/CO 비율 제어를 위해 수증기를 첨가하는 가스화 후속 공정이다. 본 연구에서는 RPF(Refuse plastic fuel) 가스화 시스템의 합성가스를 대상으로 수성가스 전환 반응을 연구하였다. 수성가스 전환 반응은 촉매를 이용하여 high temperature shift(HTS) 와 low temperature shift(LTS) 반응에 대하여 lab scale 관형 반응기를 이용하여 반응 온도, steam/carbon ratio, 유량의 변화가 H2 생성과 CO 전환율에 미치는 영향을 조사하였다. 운전 온도는 HTS 시스템이 250-400℃, LTS 시스템이 190-220℃이며 steam/carbon ratio는 1.5-3.5로 변화시켰다. 반응 모의 가스의 농도는 RPF 합성가스의 농도를 기준으로 CO, 40vol%, H2, 25vol%, CO2, 25vol%이다. 반응 온도와 steam/carbon ratio가 증가함에 따라 CO 전환율 및 H2 생성량이 증가하고, 유량이 증가하면 촉매층의 체류시간 단축으로 CO 전환율과 H2 생성량이 감소하였다.

뇌 대사물질 팬텀을 이용한 뇌의 자기공명 온도측정법에 관한 기초 연구 (Preliminary Study on Magnetic Resonance Temperature Measurement using Brain-Metabolite Phantom)

  • 한용희;장무영;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.412-416
    • /
    • 2010
  • In this study, we measured the chemical shift change of metabolite peaks in the brain-metabolite phantom according to the temperature variation using nuclear magnetic resonance(NMR). The temperature range in NMR system was controled from 25 to 80 (5 step) by internal temperature controller. Temperature coefficients of each metabolite peaks were also calculated from the measured chemical shift depending on the temperature. The chemical shift changes depending on temperature were validated by linear regression method for each metabolite peaks. The temperature coefficients of $_{tot}Cr$, Cho, Cr, NAA, and Lac were 0.0086, 0.0088, 0.0091, 0.0089, and 0.0088ppm/$^{\circ}C$, respectively. This study shows that chemical shift change of brain metabolite and temperature variation have linear relationship each other. This also makes authors believe that brain temperature measurement is possible using MR spectroscopic imaging technique.

연료전지용 고효율 촉매전이 반응의 일산화탄소 저감 (Minimization of Carbon Monoxide in the High Efficient Catalytic Shift for Fuel Cell Applications)

  • 박헌;김성천;전영남
    • 대한환경공학회지
    • /
    • 제29권5호
    • /
    • pp.528-532
    • /
    • 2007
  • 탄화수소계열의 연료로부터 고순도 수소를 생산하는 것은 연료전지의 효율적인 운전과 밀접하다. 일반적으로 대부분의 탄화수소연료에서 수소를 생산하는 과정은 수소, 일산화탄소, 이산화탄소와 수증기혼합물이 생성되는 개질과정 및 일산화탄소를 저감하는 전이반응과 선택적 산화반응 과정으로 구성되어있다. 전이반응은 일산화탄소를 이산화탄소로 전환하는 동시에 수소가 생성되는 고온전이와 저온전이로 구성된 두 단계의 촉매전환 공정이다. 전이반응은 개질가스를 고온전이 반응에서 일산화탄소를 $3\sim4%$까지 낮추며 저온전이 반응에서 0.5%까지 저감한다. 본 연구에서 개질가스 중 일산화탄소를 0.5% 이하로 저감하기 위하여 전이반응기 설계 및 실험을 진행하였다.

A STUDY OF ESTIMATION GROUND SURFACE TEMPERATURE BY TIME-SHIFT PROCESSING

  • Yano, Koji;KAJIWARA, Koji;HONDA, Yoshiaki;Moriyama, Masao
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.798-800
    • /
    • 2003
  • The time shift processing of ground measured surface temperature with the meteorological variables has no evaluated function. We introduce new evaluating function. To use this evaluating function, the algorithm of time-shift processing will be able to be reliable and get error-bar for all moving measured point's data. We will finally obtain the area averaged surface temperature by land observation.

  • PDF

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

수소 수율 증가를 위한 합성가스의 수성가스전환 반응 연구 (Water Gas Shift Reaction Research of the Synthesis Gas for a Hydrogen Yield Increase)

  • 김민경;김재호;김우현;이시훈
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2009
  • Automobile Shredder Residue (ASR) is very appropriate in a gasification melting system. Gasification melting system, because of high reaction temperature over than $1,350^{\circ}C$, can reduce harmful materials. To use the gasification processes for hydrogen production, the high concentration of CO in syngas must be converted into hydrogen gas by using water gas shift reaction. In this study, the characteristics of shift reaction of the high temperature catalyst (KATALCO 71-5M) and the low temperature catalyst (KATALCO 83-3X) in the fixed - bed reactor has been determined by using simulation gas which is equal with the syngas composition of gasification melting process. The carbon monoxide composition has been decreased as the WGS reaction temperature has increased. And the occurrence quantity of the hydrogen and the carbon dioxide increased. When using the high temperature catalyst, the carbon monoxide conversion ratio ($1-CO_{out}/CO_{in}$) rose up to 95.8 from 55.6. Compared with average conversion ratio from the identical synthesis gas composition, the low temperature catalyst was better than the high temperature catalyst.

  • PDF

A Vapor Sensor Based on a Porous Silicon Microcavity for the Determination of Solvent Solutions

  • Bui, Huy;Nguyen, Thuy Van;Nguyen, The Anh;Pham, Thanh Binh;Dang, Quoc Trung;Do, Thuy Chi;Ngo, Quang Minh;Coisson, Roberto;Pham, Van Hoi
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.301-306
    • /
    • 2014
  • A porous silicon microcavity (PSMC) sensor has been made for vapors of solvent solutions, and a method has been developed in order to obtain simultaneous determination of two volatile substances with different concentrations. In our work, the temperature of the solution and the velocity of the air stream flowing through the solution have been used to control the response of the sensor for ethanol and acetone solutions. We study the dependence of the cavity-resonant wavelength shift on solvent concentration, velocity of the airflow and solution temperature. The wavelength shift depends linearly on concentration and increases with solution temperature and velocity of the airflow. The dependence of the wavelength shift on the solution temperature in the measurement contains properties of the temperature dependence of the solvent vapor pressure, which characterizes each solvent. As a result, the dependence of the wavelength shift on the solution temperature discriminates between solutions of ethanol and acetone with different concentrations. This suggests a possibility for the simultaneous determination of the volatile substances and their concentrations.

고정도 엔진 지압계에 관한 연구 (1) <온도 특성에 의한 영점이동의 보상> (A Study on the Precision Engine Indicatior(I) (Zero-shift Compensation of the Engine Indicator with a Electronic Device))

  • 박상길;문덕홍;안수길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.34-39
    • /
    • 1983
  • Development of modern internal combustion engine requires more precise indicator. In the case of strain gage-strain tube type indicator, thermal expansion of the indicator's fixed part makes zero-shift in spite of water cooling. Therefore, the authors analyzed the cause of zero-shift phenomenon on strain gage-strain tube type indicator and proposed a new device to compensate the zero-shift of indicator by electrical method without detoriorating the dynamic charcteristic. As the results, we found that the zero-shift is varied linearlly according to temperature variation of the indicator's fixed part and appling a new device, we can improve the zero-shift of indicator about 0.63% (0.63 kg/$cm^2$) of full scale, though we got 10% of it without the device at the cylinder head operating temperature (c.a. $200^{\circ}C$).

  • PDF

Analysis of the Temperature Dependence of Phosphor Conversion Efficiency in White Light-Emitting Diodes

  • Ryu, Guen-Hwan;Ryu, Han-Youl
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.311-316
    • /
    • 2015
  • We investigate the temperature dependence of the phosphor conversion efficiency (PCE) of the phosphor material used in a white light-emitting diode (LED) consisting of a blue LED chip and yellow phosphor. The temperature dependence of the wall-plug efficiency (WPE) of the blue LED chip and the PCE of phosphor are separately determined by analyzing the measured spectrum of the white LED sample. As the ambient temperature increases from 20 to $80^{\circ}C$, WPE and PCE decrease by about 4.5% and 6%, respectively, which means that the contribution of the phosphor to the thermal characteristics of white LEDs can be more important than that of the blue LED chip. When PCE is decomposed into the Stokes-shift efficiency and the phosphor quantum efficiency (QE), it is found that the Stokes-shift efficiency is only weakly dependent on temperature, while the QE decreases rapidly with temperature. From 20 to $80^{\circ}C$ the phosphor QE decreases by about 7% while the Stokes-shift efficiency changes by less than 1%.