• 제목/요약/키워드: temperature rising test

검색결과 103건 처리시간 0.59초

극저온 환경에서의 피로균열 선단의 온도상승에 관한 연구 (A Study on Temperature Rising near Fatigue Crack Tip at Cryogenic Temperature)

  • 이준현
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.79-86
    • /
    • 1995
  • The structural materials for cryogenic technology have been recently developed to support the many modern large-scale application from superconducting magnets for nuclear fusion reactor, magnetic levitation railway to LNG tankers. However it is pointed out that quenching phenomenon is one of the serious problems for the integrity of these applications, which is mainly attributed to the rapid temperature rising in the material due to some extrinsic factors of structures. From the viewpoint of fracture mechanics, it is therefore very important to clarify the mechanism of temperature rising of structural material due to cyclic loading at cryogenic temperature. From this purpose, fatigue test was carried out for high manganese steel at liquid helium temperature(4.2K) using triangular stress waveform to identify both the mechanism of temperature rising near crack tip and the effect of loading stress waveform on temperature rising near crack tip and the effect of loading stress waveforms on temperature rising. As the results, two types of temperature rising, that is, regular and burst types were observed. And a periodical temperature rising corresponding to the stress waveforms was also found. The peaks of the temperature rising were recorded near both the maximum and the minimum values of the applied stress. The sudden temperature rises, which indicated the higher values than those of periodical temperature rises under the repetition of stress, were observed at the final region of crack growth. It was shown that the peak values of the temperature rising increased with stress intensity factor range.

3성분계 시멘트의 구성비 변화에 따른 페이스트 및 콘크리트의 내부온도 특성 (The Properties of Internal Temperature of Paste and Concrete according to Component Ratio Variation of Ternary System Cement)

  • 김연승;김동혁;지남용
    • 콘크리트학회논문집
    • /
    • 제20권6호
    • /
    • pp.797-807
    • /
    • 2008
  • 본 연구에서는 온도균열 저감이 기대되는 3성분계 시멘트를 사용한 페이스트 및 콘크리트의 간이단열온도 상승실험을 실시하여 3성분계 시멘트의 활성화를 위한 기초자료를 제공하고자 하였다. 페이스트 실험은 3가지 결합재를 단독사용 및 혼합사용 하였으며, 콘크리트 실험은 3가지 결합재를 동시에 혼입하여 실시하였다. 페이스트실험 결과 BFS보다 FA의 사용이 온도저감 효과가 좋았으며, 3성분계 시멘트페이스트에서는 BFS의 혼입률이 작고 FA의 혼입률이 클수록 온도가 낮게 나타났다. 온도상승속도 및 하강속도 또한 BFS의 혼입률이 작고 FA의 혼입률이 클수록 늦어졌다. 한편, 물결합재비가 높을수록 최고온도가 낮게 나타났다. 최고온도 도달시간은 OPC100, 2성분계 시멘트, 3성분계 시멘트 순으로 짧게 나타나 3성분계 시멘트 사용은 온도상승지연효과가 있었다. 콘크리트 실험 결과 3성분계 시멘트를 사용한 콘크리트는 OPC사용 콘크리트에 비해 최고온도가 약 $8{\sim}11^{\circ}C$ 정도 낮게 나타났고, 온도상승속도는 $47{\sim}51%$ 수준이며, 온도하강속도는 $37{\sim}42%$ 수준으로 나타났다. 콘크리트 시험체는 페이스트 시험체에 비해 현저히 낮은 온도와 느린 온도상승속도 및 하강속도를 보였는데, 이는 콘크리트 중의 골재에 의한 영향으로 페이스트 시험체보다 열손실량이 컸기 때문이다.

태양전지셀의 본질안전 방폭성능 평가 (The Intrinsic Safety Evaluation of Solar Photovoltaic Cell)

  • 이춘하;지승욱;김시국
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

Stress Corrosion Cracking in the Pre-Cracked Specimens of Type 403 Stainless Steel

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.14-19
    • /
    • 2004
  • Crack growth rate and threshold stress intensity factor for stress corrosion cracking(SCC), $K_{ISCC}$ were measured for type 403 stainless steel in 3,5% NaCl solution at room temperature and SCC was monitored by electrochemical noise technique during $K_{ISCC}$ testing. In rising load test, pits were formed at the tip of pre-crack for the pre-cracked compact tension specimen unlike in smooth round specimen in which only unstable pits were observed and hence immune to SCC. Micro-cracks were found to initiate from the pits in the former specimen, and initiation of micro-crack as well as macro-crack was detected by electrochemical noise technique in rising load $K_{ISCC}$ tests. Crack growth rate increased with increasing either displacement rate or stress intensity factor at crack initiation and was higher in rising load $K_{ISCC}$ test compared to constant load $K_{ISCC}$ test at given stress intensities.

넓은 영역의 온도범위를 가지는 급속 온도특성측정시스템 컨트롤러 설계 (Design Controller For Rapidity Temperature Measurement-system)

  • 신광식;정완영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.33-36
    • /
    • 2001
  • An automatic TCXO frequency-temperature test apparatus was firstly developed by using thermoelectric device may. The developed system swing stably the test temperature range from -40$^{\circ}C$ to +80$^{\circ}C$ for about 1 hour The rising temperature ratio was fairly linear with time in this test temperature range. The temperature could be controlled error in error range of ${\pm}$0.05$^{\circ}C$ in this system. The frequency-Temperature properties of TCXO or the thermoelectric properties of other electric device.

  • PDF

고강도용 콘크리트의 온도상승 억제를 위한 고로슬래그 미분말의 효과 (The Effect of Ground Granulated Blast-Furnace Slag on the Control of Temperature Rising in High Strength Concrete)

  • 문한영;최연왕
    • 콘크리트학회지
    • /
    • 제10권4호
    • /
    • pp.195-204
    • /
    • 1998
  • 콘크리트가 고강도를 확보하기 위해서는 일반적으로 큰 단위시멘트량 및 낮은 물-시멘트비를 유지해야 하므로 콘크리트 타설후 내부온도 상승은 필연적이며, 구조물의 위치와 온도응력차에 의하여 콘크리트 구조물에 균열이 발생하게 된다. 그러므로 고강도용 콘크리트의온도상승 억제대책의 한 방안으로 고로슬래그미분말 3종류와 혼합률 4단계로 변화시킨 콘크리트를 제조하여 온도상승량과 최고온도 도달시간 및 강도를 측정하였으며, 고로슬래그미분말을 5단계로 혼합한 페이스트의 수화발열량 및 수화속도를 측정한 값에 대하여 고찰하였다. 본 연구결과 고로슬래그미분말의 분말도 6,000$\textrm{cm}^2$/g, 혼합률 50% 정도인 고강도용 콘크리트가 온도상승 억제효과 뿐만 아니라 조기재령에서의 강도도 비교적 잘 만족하였다.

C급 플라이애쉬 콘크리트의 장기특성에 관한 연구 (The Study on Long-Terms Properties of Concrete Using C Class Fly Ash)

  • 이상수;원철;권영호;안재현;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.141-145
    • /
    • 1996
  • The primary purpose of this study is to investigate reusal techniques of by-product produced the combined heat power plant in the construction field, which may contribute to the savings of construction materials and the conservation of enviornment. This study is compared and evaluated by testing the chemical resistance, adiabatic temperature rising test, creep and drying shrinkage. As the result of the study, the following conclusions are derived : (1) hydration heat of the fly ash concrete is less than the plain concrete in adiabatic temperature rising test, (2) the fly axh concrete (FA 30%) is similar to the plain concrete in the chemical resistamce, (3) the fly ash concrete (FA 10, 30%) is similar to the plain concrete in drying shrinkage, but the fly ash concrete (FA 50%) is highly increased, (4) the fly ash concrete (FA 30%) is less than the plain concrete in creep test.

  • PDF

현장계측을 통한 교량상 분기기 축력 분석에 관한 연구 (Analysis of the axial force in CWR connected with turnout by means of the field measurement)

  • 최진유;김인재;황성호;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1289-1292
    • /
    • 2006
  • The demand on a turnout layed on a bridge is rising owing to the increasing number of stations on the viaduct. And also the demand on a turnout with CWR is rising to upgrade running speed of the passing train. A CWR connected with turnout is subjected to additional axial force induced by the actions due to change in temperature, braking and starting force, and bending of the deck. But magnitude and distribution of the axial force in rails of turnout is not clear yet. So, in this study, a field measurement was conducted to know them. The strain gage method was adopted for field test. The FBG sensor for the strain measurement was used to ensure stability of test value and durability of gage for long term. It is expected that we can get data on the axial force in rail connected with turnout with respect to seasonal temperature change by the established field test system.

  • PDF

온도 상승에 따른 내부 조직 특성에 관한 실험적 연구 -석고보드를 중심으로- (An Experimental Research on the Features of Interior Materials under High Temperature - Focusing on Gypsum Boards -)

  • 김광기;박선길;김우재;임남기;송병창;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.305-310
    • /
    • 2003
  • Recently, gypsum boards are widely used as interior finishing boards for constructions because of their features of absorbing heats and little temperature rising at the early stage of fire. Therefore, in this research, basic data were suggested to secure fireproof stability by investigating interior processing features, which change together with the backside temperature of test materials from Flash Over (within 30 minutes after firing), at which temperature reaches its highest point, to survey the features of materials due to rising temperature in the chase of gypsum boards (general and fireproof gypsum boards)

  • PDF

석탄 가스화 용융 슬래그를 잔골재로 사용한 콘크리트 단열온도상승 특성 (Properties of Adiabatic Temperature Rising of Concrete Using Coal Gasification Slag as Fine Aggregate)

  • 한준희;임군수;최일경;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.114-115
    • /
    • 2021
  • The research team conducted a series of studies to use CGS as fine aggregate for concrete. In this paper, through the adiabatic temperature rising test, CGS' hydration heating performance and its usability as a mass concrete hydration heating agent were reviewed. According to the analysis, the maximum temperature of the mix of OPC 100 was 53.7℃, and the temperature of CGS 50% was 45.2℃, which was 8.5℃ lower than the OPC 100.

  • PDF