• 제목/요약/키워드: temperature pulse

검색결과 885건 처리시간 0.028초

남녀 대학생에서 십선혈(十宣穴) 사혈(瀉血)이 혈압, 체온 및 맥박수에 미치는 영향 (Effects of Venesection at the Sybsun-points on Blood Pressure and Body Temperature and Pulse Rate in Humans)

  • 이동건;정원제;이현진;조현석;김경호;김갑성
    • Journal of Acupuncture Research
    • /
    • 제25권4호
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives : Sypsun-points are located at the tips of all fingers, 0.1 chon(寸) from the finger nails, totaling 10 points on both hands. These points have been used for emergency care, fainting, epilepsy, cerebrovascular accidents, hypertension, unconsciousness, high fever etc. in oriental medicine. The most common technique is bleeding with a needle at these points. We investigated whether Venesection at the Sybsun-points has effects on blood pressure and body temperature and pulse rate in humans aged from 20 to 30 who had no specific past history and whose vital signs are in normal range. Methods : 67 persons were studied from March to June 2008. They were composed of Sample group(n=36) and Normal group(n=31). Both two groups kept a steady state an hour before venesection. In both group, we checked blood pressure and body temperature and pulse rates 6 times( 30min. before and just before treatment, and just after, 30, 60, 90min after treatment). All study environments were same between sample and normal group. But only, normal group didn't carry out venesection at the Sybsun-points. Results : In a comparison of before and after venesection at the Sybsun-points, any Statistical significance was not evaluated. Though pulse rate in sample group was significantly decreased after venesection(p<0.05), it has no statistical significance because normal group's pulse rate was also significantly decreased and between two groups had no statistical difference. Conclusions : Though further study is needed, our findings suggest that venesection at the Sybsun-points has no significant effect on blood pressure and body temperature, and pulse rate in humans who had no specific past history and whose vital signs are in normal range. Also in that case, we may know that pain and tension result from venesection at the Sybsun-points have no significant effect on blood pressure and body temperature and pulse rate.

  • PDF

Thermoviscoelastic orthotropic solid cylinder with variable thermal conductivity subjected to temperature pulse heating

  • Abouelregal, A.E.;Zenkour, A.M.
    • Earthquakes and Structures
    • /
    • 제13권2호
    • /
    • pp.201-209
    • /
    • 2017
  • This work aims to analyze the thermo-viscoelastic interaction in an orthotropic solid cylinder. The medium is considered to be variable thermal conductivity and subjected to temperature pulse. Analytical solution based on dual-phase-lags model with Voigt-type for behavior of viscoelastic material has been effectively proposed. All variables are deduced using method of Laplace transforms. Numerical results for different distribution fields, such as temperature, displacement and stress components are graphically presented. Results are discussed to illustrate the effect of variability thermal conductivity parameter as well as phase-lags and viscoelasticity on the field quantities. Results are obtained when the viscosity is ignored with and without considering variability of thermal conductivity. A comparison study is made and all results are investigated.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

박판 Al MIG 용접용 AC펄스 전류 파형의 설계 및 출력특성 (Design and Output Characteristic of AC Pulse Current for MIG Welding of Ai Sheet)

  • 조상명;김태진;이창주;임성룡;공현상;김기정
    • Journal of Welding and Joining
    • /
    • 제21권2호
    • /
    • pp.57-63
    • /
    • 2003
  • Since new types of vehicles or structures made from thin aluminum alloy are under rapid development and some products are already on the market, welding of aluminium sheet is increasing. MIG(Metal Inert Gas), MIG-Pulse, TIG(Tungsten Inert Gas) welding are the typical Ai welding. MIG welding has the advantage of high speed, but it is difficult to apply to the thin plate, because of bum-through by the high heat input and spatter. MIG-Pulse welding can weld without spatter and burn-through, but when the gap exists at the welding joint, there is quite a possibility of bum-through. TIG welding is difficult to weld at a high speed. AC Pulse welding alternates between DCEP(Direct Current Electrode Positive) and DCEN(Direct Current Electrode Negative). DCEN is higher wire melting rate than DCEP, while lower temperature of droplet than DCEP. In AC Pulse welding, far fixed welding current, wire melting rate increases as the EN ratio increases. For fixed wire feed rate, welding current decreases as the EN ratio increases. Because of these features, the temperature of droplet, the depth of penetration, the width of bead decrease and the reinforcement height increases as EN ratio increases, and these are able to weld at a high speed, lower heat input. It is the purpose of this study that design of AC pulse current waveform for MIG welding of Al sheet and estimation of output characteristic.

Duplex Stainless Steel의 저온 플라즈마 침질탄화시 Pulse Frequency 및 Duty Factor에 따른 표면 특성평가 (The Influence of Pulse Frequency and Duty Factor on Surface Characteristics during Low Temperature Plasma Nitrocarburizing Treatment of Duplex Stainless Steel)

  • 천창석;이인섭
    • 한국표면공학회지
    • /
    • 제47권5호
    • /
    • pp.221-226
    • /
    • 2014
  • A low temperature plasma nitrocarburizng was implemented on the duplex stainless steel to achieve the enhancement of surface hardness without degradation of its corrosion resistance. Attempts were made to investigate the influence of Pulse frequency and Duty factor of pulsed power in a high Pulse frequency regime on the surface characteristics of the hardened layer. The hardened layer (S-phase) was formed on all of the treated surfaces. Surface hardness reached up to 1300 $HV_{0.1}$ which is about 4.6 times higher than that of the untreated material (280 $HV_{0.1}$). The thickness of the hardened layer tends to increase lightly with the higher Pulse frequency and the higher Duty factor. The corrosion resistance of nitrocarburized duplex stainless steel was almost similar to that of the untreated material. Both the Pulse frequency and the Duty factor do not have a significant influence on the corrosion property of plasma treated duplex stainless steel.

주기적인 유동과 압력의 변화를 수반하는 맥동관의 열전달계수와 전단계수 (Heat Transfer Coefficient and Shear Factor Subjected to Both Oscillating Flow and Oscillating Pressure in Pulse Tubes)

  • 정은수
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.220-227
    • /
    • 2007
  • Heat transfer and momentum transfer under conditions of both oscillating flow and oscillating pressure within pulse tubes show very different behavior from those for steady state conditions. The analytic solutions of axial velocity and temperature of the gas within pulse tubes were obtained by assuming that the variations in pressure and temperature were purely sinusoidal and small. The shear stress and the heat flux at the tube wall obtained from the solutions are expressed in terms of the cross-sectional averaged velocity, the difference between mean temperature and instantaneous cross-sectional averaged temperature and the difference between mean pressure and instantaneous pressure. It is shown that the complex shear factor, which has been applied to momentum transfer of incompressible oscillating flow, and the complex Nusselt number, which has been applied to either heat transfer with oscillating pressure only or heat transfer of incompressible oscillating flow, could also be used for momentum transfer and heat transfer subjected to both oscillating flow and oscillating pressure, respectively.

Three buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of Three Buffer Pulse Tube Refrigerator)

  • 박성제;고득용;김효봉;신완순
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

맥동관 냉동기의 유형별 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics for the Three Types of the Pulse Tube Refrigerators)

  • 박성제;고득용
    • 연구논문집
    • /
    • 통권24호
    • /
    • pp.27-39
    • /
    • 1994
  • lower vibration than in any other small refrigerators. The experimental results of three types of pulse tube refrigerators are presented in this paper. The objectives of this study are to develop the design technology of the double inlet pulse tube refrigerator and acquire its application method. As a preliminary experiment, the refrigeration performances of the basic, orifice and double inlet pulse tube refrigerator were investigated. The lowest temperature obtained in this experiment was 34.4K. The refrigeration capacity at the optimum operating condition of the double inlet pulse tube refrigerator was 23W at 80K.

  • PDF

모듈레이티드 펄스 스퍼터링으로 상온 증착한 Indium-Tin-Oxide (ITO) 나노 박막 (Indium Tin Oxide (ITO) Nano Thin Films Deposited by a Modulated Pulse Sputtering at Room Temperature)

  • 유영군;정진용;주정훈
    • 한국표면공학회지
    • /
    • 제47권3호
    • /
    • pp.109-115
    • /
    • 2014
  • High power impulse magnetron sputtering (HIPIMS), also known as the technology is called peak power density in a short period, you can get high, so high ionization sputtering rate can make. Higher ionization of sputtered species to a variety of coating materials conventional in the field of improving the characteristics and self-assisted ion thin film deposition process, which contributes to a superior being. HIPIMS at the same power, but the deposition speed is slow in comparison with DC disadvantages. Since recently as a replacement for HIPIMS modulated pulse power (MPP) has been developed. This ionization rate of the sputtered species can increase the deposition rate is lowered and at the same time to overcome the problems to be reported. The differences between the MPP and the HIPIMS is a simple single pulse with a HIPIMS whereas, MPP is 3 ms in pulse length is adjustable, with the full set of multi-pulses within the pulse period and the pulse is applied can be micro advantages. In this experiment, $In_2O_3$ : $SnO_2$ composition ratio of 9 : 1 wt% target was used, Ar : $O_2$ flow rate ratio is 4.8 to 13.0% of the rate of deposition was carried out at room temperature. Ar 40 sccm and the flow rate of $O_2$ and then fixed 2 ~ 6 sccm was compared against that. The thickness of the thin film deposition is fixed at 60 nm, when the partial pressure of oxygen at 9.1%, the specific resistance value of $4.565{\times}10^{-4}{\Omega}cm$, transmittance 86.6%, mobility $32.29cm^2/Vs$ to obtain the value.