• 제목/요약/키워드: temperature pulse

검색결과 885건 처리시간 0.024초

펨토초급 극초단 펄스레이저에 의해 가열된 실리콘 내의 열전달 특성에 관한 수치해석 (Numerical Analysis on Heat Transfer Characteristics in Silicon Boated by Picosecond-to-Femtosecond Ultra-Short Pulse Laser)

  • 이성혁;이준식;박승호;최영기
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1427-1435
    • /
    • 2002
  • The main aim of the present article is numerically to investigate the micro-scale heat transfer phenomena in a silicon microstructure irradiated by picosecond-to-femtosecond ultra-short laser pulses. Carrier-lattice non-equilibrium phenomena are simulated with a self-consistent numerical model based on Boltzmann transport theory to obtain the spatial and temporal evolutions of the lattice temperature, the carrier number density and its temperature. Especially, an equilibration time, after which carrier and lattice are in equilibrium, is newly introduced to quantify the time duration of non-equilibrium state. Significant increase in carrier temperature is observed for a few picosecond pulse laser, while the lattice temperature rise is relatively small with decreasing laser pulse width. It is also found that the laser fluence significantly affects the N 3 decaying rate of Auger recombination, the carrier temperature exhibits two peaks as a function of time due to Auger heating as well as direct laser heating of the carriers, and finally both laser fluence and pulse width play an important role in controlling the duration time of non-equilibrium between carrier and lattice.

Brain MRI 검사 시 치아 임플란트 시술유무와 RF Pulse 세기에 따른 인체 영향에 관한 연구: XFDTD 프로그램을 이용 (Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program)

  • 최대연;김동현
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.361-370
    • /
    • 2017
  • Brain MRI 검사에서는 영상을 얻기 위해 RF Pulse를 인체에 조사하게 되는데 이때 조사된 RF Pulse 에너지의 상당 부분은 우리 몸에 그대로 흡수되게 되고 이로 인해 인체 온도가 상승하게 되는데 노출 정도에 따라 인체에 영향을 주게 된다. 이러한 RF Pulse 에너지는 MRI 장비의 발전으로 인해 자기장의 세기가 1.5 Tesla에서 3 Tesla, 3 Tesla에서 7 Tesla로 높아지는 시점에서 자기장의 세기 변화에 따른 두부 전체의 SAR와 온도의 변화를 알아보고 위의 결과가 치아 임플란트 사용 여부에 따른 결과의 차이를 알아보기 위해 연구를 시작하게 되었다. 실험은 인체 두부 모델에 1.5 Tesla MRI 장비에서 발생되는 64 MHz RF Pulse 주파수, 3.0 Tesla MRI 장비에서 발생되는 128 MHz RF Pulse 주파수, 7 Tesla MRI 장비에서 발생되는 298 MHz RF Pulse 주파수를 조사하고 위의 실험을 치아 임플란트를 사용하였을 때와 사용하지 않았을 때로 나누어 XFDTD 프로그램을 사용하여 머리 주변의 SAR와 체온의 변화를 각각 실험하였다. 치아 임플란트를 하지 않았을 때보다 치아 임플란트를 하였을 때 SAR값은 7T의 RF Pulse 주파수 256MHz에서 최대 약 5800배의 차이를 나타냈으며 주파수가 증가할수록 치아 임플란트 사용으로 인한 SAR값의 차이는 크게 나타났다. 치아 임플란트를 하지 않았을 때보다 치아 임플란트를 하였을 때 두부전체의 온도변화는 2배에서 최대 4배 가까운 온도 상승을 나타내었다. 또한 RF Pulse 주파수가 증가할수록 SAR값은 증가하지만, 두부 전체의 온도는 감소하였는데 이는 주파수가 증가할수록 파장이 작을수록 인체표면에 흡수되는 양이 많아지기 때문이다. 향후 치아 임플란트 유무와 RF Pulse 주파수의 세기 변화로 인한 이상 반응 요인에 대한 연구를 통해 인체의 생리적 연구와 생화학적 연구 등 인체에 대한 영향과 관련하여 연구가 필요하다고 하겠다.

펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구 (Investigation on vapor-cooled current leads operating in pulse mode)

  • 인세환;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

2종류의 양말착의행동이 인체생리반응에 미치는 효과 (Effects of Two Kifferent Kinds of Socks on Physiologrical Responses)

  • 김희은;권오경
    • 한국의류학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

금개구리(Rana plancyi)의 소리 유형과 수온에 따른 소리변화 (The Call Patterns and the Change of Calls by Water Temperature in Rana plancyi (Amphibia, Anura))

  • 박시룡;이병근;양서영
    • The Korean Journal of Ecology
    • /
    • 제21권3호
    • /
    • pp.269-276
    • /
    • 1998
  • The study of the Rana plancyi, was done during the calling period at a pond in Osong, Chungbuk, Korea from May to the middle of August of 1996 and 1997. Five basic types of call-A, B, C, D, E, - were identified in Rana plancyi according to the structure of call types. The structure of A type call has only one pulse, B type call has two pulses and C, D type call has one separated pulse which is called introductory call and pulse group as follow it. On the other hand, E type call has 3-6 separate pulses. The interval between introductory call and pulse group is $0.73{\pm}0.29$ s(n=159) in C type call and $0.60{\pm}0.21$ s (n=48) in D type call. The number of pulses in the pulse group is $30.08{\pm}8.69$ in C type call and $15.78{\pm}2.40$ in D type call. An increase in water temperature induces a decrease in C and D type call duration (C type call r= -0.4153, p<0.001, D type call r=-0.7064, p<0.001). In case of C and D type call, the interval between introductory call and pulse group influenced more call duration than pulse group duration. We regarded A, B type call as a territorial call and C, D type call as a mating call and we recognized that E type call has the function of threat or alarm.

  • PDF

펄스 모듈레이션된 고주파 플라즈마의 시변 특성 (Time variation characteristic of pulse-modulated high frequency plasma)

  • 이선홍;이대성;조용성;김동현;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1817-1819
    • /
    • 2004
  • From the plasma application point of view, electron temperature and density are one of the most important parameters for plasma process. But it is only available to control plasma by adjusting external factors like gas pressure and input power. In this paper, pulse-modulated plasma is generated by modulating 13.56GHz RF power with 1, 5, 10kHz pulse. And Langmuir probe technique is used to study the distribution of electron temperature and density. When modulated pulse is off, electron temperature decreases gradually in form of exponential decay. The value t of exponential decay slope is 33.619, 13.834, 10.803 in 1kHz. 5kHz. 10kHz. This implies that this method can be used to control electron temperature and density.

  • PDF

맥동관 내부의 열전달에 관한 실험적 연구 (Experimental study on the transfer in pulse tube)

  • 김민규;남관우;정상권;장호일;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF

Effects of Temperature Coefficients for Dielectric Constants on Thermoreflectances and Thermal Responses of Metal Thin Films Exposed to Ultrashort Pulse Laser Beams

  • Seungho Park
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2002
  • Effects of temperature coefficients fur dielectric constants on transient reflectances and thermal responses have been investigated for a metal(gold) thin-film during ultrashort pulse laser heating. Heating processes are simulated using the conventional conduction model(parabolic one-step, POS), the parabolic tow-step model(PTS), the hyperbolic two-step model(HTS). Results fro the HTS model are very similar to those from the PTS model, since the laser heating time in this study is considerably greater than the electron relaxation time. PTS and HTS models, however, result in completely different temperature profiles from those obtained by the POS model due to slow electron-lattice interactions compared to laser pulse duration. Transient reflectances are directly estimated from the linear relationship between electron temperature and complex dielectric constants, while conventional approaches assume that the change in reflectances is proportional to that in temperatuer. Reflectances at the front surface vary considerably for various dielectric constants, while those at the rear surface remain unchanged relatively.

Effect of ramp-type erase pulse waveform on the high Temperature driving characteristics of ac PDP

  • Choi, Joon-Young;Kim, Dong-Hyun;Heo, Jeong-Eun;Ryu, Sung-Nam;Ryu, Jae-Hwa;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.57-60
    • /
    • 2002
  • This paper deals with the effect of ramp-type erase pulse waveform on the high temperature driving characteristics of ac PDP driven by ramp up-down reset waveform. The experimental results show that the discharge characteristics in the reset period are significantly affected by the erase pulse waveform and ambient temperature. The firing voltage is increased with ambient temperature. This can cause misfirings during the sustain period and should be avoided. As one of possible solutions, we propose the optimization of erasing pulse shape.

  • PDF

밴드갭 기준전압을 이용한 동작온도에 무관한 PWM 컨트롤러 (A Temperature Stable PWM Controller Using Bandgap Reference Voltage)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제11권8호
    • /
    • pp.1552-1557
    • /
    • 2007
  • 본 논문에서는 밴드갭 기준전압을 이용하여 동작온도에 무관한 PWM(Pulse Width Modulation) 제어 회로를 설계 하였다. 동작온도에 무관한 PWM 제어기는 BiCMOS 기술을 이용하여 동작온도에 무관한 기준전압과 동작온도에 따라 변화하는 두개의 기준 전압을 이용하였다. 설계되어진 회로는 공급전압 3.3volt를 사용하였으며, 출력 주파수는 1MHz이다. 회로의 시뮬레이션 결과 동작 온도가 $0^{\circ}C$에서 $70^{\circ}C$까지 변화할 때, PWM 제어기의 출력 펄스폭의 변화는 상온에 비하여 +0.86%에서 -0.38%였다.