• Title/Summary/Keyword: temperature monitor

Search Result 681, Processing Time 0.022 seconds

Development of Precise Measuring System for Hot Strip Mill's Rolls (열간압연용 롤 정밀 측정시스템 개발)

  • 이성진;이영진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF

Application of the Arrhenius Equation in Geotechnical Engineering

  • Yoon, Hyung-Koo
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.575-581
    • /
    • 2014
  • The reliable measurement of geotechnical properties in cold regions should account for their fluctuations with temperature. The objective of this paper is to introduce a chemical model based on the Arrhenius equation that can predict the properties of materials as their temperature changes. The model can monitor phases and reaction rates as they change with temperature. It has been already applied in the fields of geology, construction, chemistry, materials engineering, and food science. The application of the Arrhenius equation requires a reliable estimate of the activation energy. Therefore, this study also demonstrates several methods for evaluating activation energy in different contexts through summaries and reviews of previous research related to the Arrhenius equation. This paper may be of wide use in obtaining temperature-dependent parameters in geotechnical engineering.

Methods and Systems for High-temperature Strain Measurement of the Main Steam Pipe of a Boiler of a Power Plant While in Service

  • Guang, Chen;Qibo, Feng;Keqin, Ding
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.770-777
    • /
    • 2016
  • It has been a challenge for researchers to accurately measure high temperature creep strain online without damaging the mechanical properties of the pipe surface. To this end, a noncontact method for measuring high temperature strain of a main steam pipe based on digital image correlation was proposed, and a system for monitoring of high temperature strain was designed and developed. Wavelet thresholding was used for denoising measurement data. The sub-pixel displacement search algorithm with curved surface fitting was improved to increase measurement accuracy. A field test was carried out to investigate the designed monitoring system of high temperature strain. The measuring error was less than $0.4ppm/^{\circ}C$, which meets actual measurement requirements for engineering. Our findings provide a new way to monitor creep damage of the main steam pipe of a boiler of an ultra-supercritical power plant in service.

Analysis for luminescence property about an increase quantity of silicate phosphor and reliability (Silicate 형광체 증가에 대한 발광 특성 및 신뢰성 분석)

  • Yoon, Yanggi;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.12 no.4
    • /
    • pp.275-285
    • /
    • 2012
  • This paper presents a changes of luminescence property for converted white LEDs with the commercially available silicate phosphor. If silicate phosphor's quantity increase step by step. luminescence property will be changing. we analyze luminescence property for these change and carry out the high temperature aging test for 7,000 hours, the high temperature and humidity aging test for 7,000 hours for reliability. LED degradation not only results in reduced light output but also in color changes. so we monitor correlated color temperature (CCT), chromaticity coordinates(x, y) and spectrum intensity. Those results suggest that humidity factor more bad effect in color changes than temperature factor and Lighting quality is related with quantity of phosphor.

Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method (능동열시험법을 이용한 몰드변압기 진단)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

TEMPERATURE CONTROL AND COMPRESSIVE STRENGTH ASSESSMENT OF IN-PLACE CONCRETE STRUCTURES USING THE WIRELESS TEMPERATURE MEASURING SYSTEM BASED ON THE UBIQUITOUS SENSOR NETWORK

  • Ho Kyoo JO;Hyung Rae KIM;Tae Koo KIM
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.794-799
    • /
    • 2009
  • The temperature control of in-place concrete is the most important factor for an early age of curing concrete. Heat stress of mass concrete caused by the heat of hydration can induce the crack of concrete, and a frost damage from cold weather casting concrete results defect on compressive strength and degradation of durability. Therefore, success and failure of concrete work is dependant on the measurement and control of concrete temperature. In addition, the compressive strength assessment of in-place concrete obtained from the maturity calculated from the history of temperature make a reduction of construction cycle time, possible. For that purpose, wireless temperature measuring system was developed to control temperature and assess strength of concrete. And, it was possible to monitor the temperature of concrete over 1km apart from site office and to take a proper measure; mesh-type network was developed for wireless sensor. Furthermore, curing control system that contains the program capable to calculate the maturity of concrete from the history of temperature and to assess the compressive strength of concrete was established. In this study, organization and practical method of developed curing control system are presented; base on in-place application case.

  • PDF

The Use of Sticker Type Temperature Indicator in Stellate Ganglion Block (성상신경절 차단시 부착형 피부온도계의 사용 경험)

  • Yoon, Duck-Mi;Oh, Hung-Kun;Keiji, Ishizaki;Fujita, Tatsushi
    • The Korean Journal of Pain
    • /
    • v.7 no.1
    • /
    • pp.49-52
    • /
    • 1994
  • Measurement of skin temperature is most frequently used to evaluate effect of sympathetic block. Sticker type skin temperature indicator, $ProChecker^{(R)}$, uses metamocolor, which changes the darkness of the color by giving and taking of electrons in response to temperature. We examined the accuracy of this skin temperature indicator in pain clinic patients who were treated with stellate ganglion block. Ten minutes before, and 10~20 minutes after stellate ganglion block, skin temperature on both dorsum of hand were measured using both $ProChecker^{(R)}$ and thermography concurrently. The results showed that skin temperature measured by $ProChecker^{(R)}$ was feasible, in correlation to thermography. Sticker type temperature indicator ($ProChecker^{(R)}$) is concluded as a useful monitor of skin temperature during nerve block in outpatient clinics.

  • PDF

Implementation of Real-Time Monitoring System for Livestock Growth Environment Information using Wireless Sensor Network (무선센서 네트워크를 이용한 가축생육환경정보 실시간 모니터링 시스템 구현)

  • Kim, Young-Wung;Paik, Seung-Hyun;Jon, Yong-Jun;Lee, Dae-Ki;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.6
    • /
    • pp.301-309
    • /
    • 2012
  • In this paper, a real-time monitoring system based on WSN is designed and implemented to monitor livestock growth environment information which includes the temperature, humidity and harmful gases such as $CO_{2},\;CO,\;NH_{3},\;H_{2}S$ and so on. The proposed system consists of the wireless sensor nodes, the monitoring management device, the management server and the user interface program based on PC/Smart phone. To verify the performance of the implemented system, gas measurement experiments are performed in laboratory environment by using the designed wireless sensor nodes. And it is able to estimate the concentration of gases. The implemented system is able to monitor the proposed environmental element information through the developed GUI.

Fiber optic 산소센서를 이용한 생물공정의 모니터링

  • Lee, Jong-Il;Comte, Andreas;Hung, Lam Tuan;Kim, Jun-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.569-571
    • /
    • 2000
  • A fiber optic oxygen sensor has been employed to monitor the concentrations of dissolved oxygen in a bioreactor. The characteristics of fiber optic oxygen sensor was investigated, e.g. the dependency of agitation rate on the oxygen measurement and also the dependence of temperature on the performance of fiber optic oxygen sensor etc. We have also applied to monitor the concentrations of dissoved oxygen in real cultivation processes by using the fiber optic oxygens sensor. The fiber optic oxygen sensor can be applied to measure the concentration of metabolites by immobilizing some enzymes, e.g. glucose oxidase and also employed for the environmental technology.

  • PDF