• 제목/요약/키워드: temperature minimum layer

검색결과 141건 처리시간 0.03초

The Inflow Path of the East Sea Intermediate Water into the Ulleung Basin in July 2005

  • Shin, Chang-Woong
    • Ocean and Polar Research
    • /
    • 제28권2호
    • /
    • pp.153-161
    • /
    • 2006
  • To investigate inflow path of the East Sea Intermediate Water (ESIW) into the Ulleung Basin, hydrographic data surveyed in July 2005 were analyzed. The ESIW was characterized by the Salinity Minimum Layer (SML) within a depth range of 100 to 360 meters. Averaged potential temperature and salinity of the SML were $1.835^{\circ}C$ and 34.049 psu, respectively. Mean potential density $({\sigma}_{\theta})$ of the SML was 27.221 with a standard deviation of 0.0393. On isopycnal surfaces of 27.14 and 27.18 $({\sigma}_{\theta})$ which correspond to upper layers of the ESIW, the coastal low salinity water was separated from the offshore low salinity water by the relatively warm and saline water which might be affected by the Tsushima Warm Current Water. Relatively cold and fresh water, however, intruded into the Ulleung Basin from the region of Korean coast on isopycnal surfaces of 27.22 and 27.26 which was lower layer of the ESIW. The salinity distribution in the isopycnal layer of $27.14{\sim}27.26$ with acceleration potential on 27.22 up surface also showed clearly that the low salinity water flowed from the coastal area and intruded into the Ulleung Basin. This implies that the ESIW flows ken the north to the south along the east coasts of Korea and spreads into the Ulleung Basin in summer.

자연대류를 고려한 전류도입선의 최적설계 (Optimal design of Current lead considering Natural convection)

  • 손봉준;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.103-108
    • /
    • 2003
  • In this paper, the current lead for superconducting device is studied by numerical method. The current lead is cooled by surrounded $N_{2}$ gas by natural convection. The heat conduction equation for current lead and boundary layer equation for $N_{2}$ gas must be solved simultaneously. The boundary layer equation for $N_{2}$ gas is highly nonlinear for varied temperature of current lead. So the linearization method is adopted for simplicity. Numerical results using natural convection cooling are compared with the conventional cooling methods such as conduction cooling and vapor cooling methods. The main difference of natural convection cooing is the non-zero temperature gradient at the top of current lead for the minimum heat dissipation into superconducting devices. For the optimized conduction-cooling and vapor-cooling current leads, the temperature gradient at the top of current lead is zero. Also, the heat flow at the cold end is much smaller than conduction cooling case.

  • PDF

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

침탄처리한 Ni-Cr-Mo강의 마찰-마모특성 (Friction-Wear Properties of Carburized SNCM)

  • 백승호
    • 열처리공학회지
    • /
    • 제11권3호
    • /
    • pp.159-167
    • /
    • 1998
  • In this study, friction-wear test was carried out on the carburized layer depth of a mechanical structure steel SNCM carburized with RX and LPG for 7hrs at $930^{\circ}C$ and also the wear properties of wear loss, wear rate, coefficient of friction, friction force and friction temperature were investigated. The wear properties for carburized layer of SNCM were tested on dry condition at the room temperature by the thrust load of 49~245N range at sliding speed of 0.2m/sec and the sliding speed of 0.2~1.0m/sec range at thrust load of 98N. Wear loss on the depth of carburizing layer was increased with increasing of thrust load and sliding speed, and with decreasing of hardness. The condition of worn surfaces were showed mild wear at less than the thrust load of 98N and sliding speed of 0.6m/sec but were showed severe wear at more than 98N and 0.6m/sec. The friction load and temperature were increased with increasing of thrust load but with increasing sliding speed was appeared minimum at 0.6m/sec. With increasing thrust load the wear rate was increased and the coefficient of friction was decreased, but with increasing sliding speed the wear rate and the coefficient of friction were decreased in 0.2~0.6m/sec and increased in 0.6~1.0m/sec, therefore 0.6m/sec in this testing is a transition velocity.

  • PDF

열전달 및 물질전달을 이용한 공극 발열도로에서의 융설 해석에 대한 이론적 연구 (Theoretical Study on Snow Melting Process on Porous Pavement System by using Heat and Mass Transfer)

  • 윤태영
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.1-10
    • /
    • 2015
  • PURPOSES : A finite difference model considering snow melting process on porous asphalt pavement was derived on the basis of heat transfer and mass transfer theories. The derived model can be applied to predict the region where black-ice develops, as well as to predict temperature profile of pavement systems where a de-icing system is installed. In addition, the model can be used to determined the minimum energy required to melt the ice formed on the pavement. METHODS : The snow on the porous asphalt pavement, whose porosity must be considered in thermal analysis, is divided into several layers such as dry snow layer, saturated snow layer, water+pavement surface, pavement surface, and sublayer. The mass balance and heat balance equations are derived to describe conductive, convective, radiative, and latent transfer of heat and mass in each layer. The finite differential method is used to implement the derived equations, boundary conditions, and the testing method to determine the thermal properties are suggested for each layer. RESULTS: The finite differential equations that describe the icing and deicing on pavements are derived, and we have presented them in our work. The framework to develop a temperature-forecasting model is successfully created. CONCLUSIONS : We conclude by successfully creating framework for the finite difference model based on the heat and mass transfer theories. To complete implementation, laboratory tests required to be performed.

Solenoid Type 3-D Passives(Inductors and Trans-formers) For Advanced Mobile Telecommunication Systems

  • Park, Jae Y.;Jong U. Bu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.295-301
    • /
    • 2002
  • In this paper, solenoid-type 3-D passives (inductors and transformers) have been designed, fabricated, and characterized by using electroplating techniques, wire bonding techniques, multi-layer thick photoresist, and low temperature processes which are compatible with semiconductor circuitry fabrication. Two different fabrication approaches are performed to develop the solenoid-type 3-D passives and relationship of performance characteristics and geometry is also deeply investigated such as windings, cross-sectional area of core, spacing between windings, and turn ratio. Fully integrated inductor has a quality factor of 31 at 6 GHz, an inductance of 2.7 nH, and a self resonant frequency of 15.8 GHz. Bonded wire inductor has a quality factor of 120, an inductance of 20 nH, and a self resonant frequency of 8 GHz. Integrated transformers with turn ratios of 1:1 and n:l have the minimum insertion loss of about 0.6 dB and the wide bandwidth of a few GHz.

Community Dynamics and Distribution of Dinoflagellates and Their Cysts in Masan-Chinhae Bay, Korea

  • Lee Joon-Baek;Kim Dae Yun;Lee Jin Ae
    • Fisheries and Aquatic Sciences
    • /
    • 제1권2호
    • /
    • pp.283-292
    • /
    • 1998
  • The community dynamics and distribution of dinoflagellates and their cysts were monitored monthly from June 1996 to May 1997 at six stations in Masan-Chinhae Bay, one of the famous bays for red-tide occurrence in Korea. The dinoflagellate standing crops ranged from the minimum of 306 cells $ml^{-1}$ in February to the maximum of 37,959 cells $ml^{-1}$ in May. The species causing massive blooms were Prorocentrum micans Ehrenberg and Ceratium furca (Ehrenberg) Claparede & Lachmann in July, Gymnodinium sanguineum Hirasaka in October, Alexandrium tamarense (Lebour) Balech in April and Proroeentrum minimum (Pavillard) Schiller in May. Twenty-seven taxa of dinoflagellate cysts were isolated, including 20 identified species and 7 unidentified species. The mean cyst abundance ranged from the minimum of 556 cysts $cm^{-3}$ in June to the maximum of 5,727 cysts$cm^{-3}$ in February. The spatial pattern of cyst distribution showed the gradual increase in abundance from offshore to inshore stations. The cyst genera of Protoperidinium, Gymnodinium, Serippsiella, Gyrodinium and Alexandrium were abundant throughout the year. The vertical distribution of cysts showed the surface miximum at the 0-2cm layer and the sub-surface maximum at the 2-4cm layer. Total abundance of cysts showed the most significant relationships with water temperature, and some minor relationship with dissolved oxygen, salinity, pH, phosphate and total inorganic nitrogen of surface and bottom layer in the water column. The number of dinoflagellate species decreased, while the abundance of cysts increased 4.5 times as compared with the observation of 10 years prior to the present study at the same stations of Masan-Chinhae Bay.

  • PDF

석탄-바이오매스 혼소에 따른 슈퍼히터 튜브 고온 부식 특성 연구 (High-Temperature Corrosion Characterization for Super-Heater Tube under Coal and Biomass Co-firing Conditions)

  • 박석균;목진성;정진무;오종현;최석천
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.79-86
    • /
    • 2018
  • Many countries have conducted extensive studies for biomass co-firing to enhance the durability of reactor on high-temperature corrosion. However, due to the complicated mechanisms of biomass co-firing, there have been limitations in accurately determining the current state of corrosion and predicting the potential risk of corrosion of power plant. In order to solve this issue, this study introduced Lab-scale corrosion system to analyze the corrosion characteristics of the A213 T91 material under the biomass co-firing conditions. The corrosion status of the samples was characterized using SEM/EDS analysis and mass loss measurement according to various biomass co-firing conditions such as corrosion temperature, $SO_2$ concentration, and corrosion time. As a result, the corrosion severity of A213 T91 material was gradually increased with the increase of $SO_2$ concentration in the reactor. When $SO_2$ concentration was changed from 0 ppm to 500 ppm, both corrosion severity and oxide layer thickness were proportionally increased by 15% and 130%, respectively. The minimum corrosion was observed when the corrosion temperature was $450^{\circ}C$. As the temperature was increased up to $650^{\circ}C$, the faster corrosion behavior of A213 T91 was observed. A213 T91 was observed to be more severely corroded by the effect of chlorine, resulting in faster corrosion rate and thicker oxide layer. Interestingly, corrosion resistance of A213 T91 tended to gradually decrease rather than increases as the oxide layer was formed. The results of this study is expected to provide necessary research data on boiler corrosion in biomass co-firing power plants.

O2 분위기에서 p-GaN 층의 Mg 활성화가 GaN계 녹색 발광소자에 미치는 전류-전압특성 (The Influence of the Mg-doped p-GaN Layer Activated in the O2 Ambient on the Current-Voltage Characteristics of the GaN-Based Green LEDs)

  • 윤창주;배성준
    • 한국전기전자재료학회논문지
    • /
    • 제15권5호
    • /
    • pp.441-448
    • /
    • 2002
  • The electrical properties of the GaN-based green light emitting diodes(LEDs) with the Mg-doped p-GaN layer activated in $N_2$ or $O_2$ ambient have been compared. For the $N_2$ -ambient activation the current-voltage behavior of LEDs has been found to be improved when the Mg dopants activation was performed in the higher temperature. However, for the $O_2$-ambient activation the current-voltage characteristic has been observed to be enhanced when the Mg dopants activation was carried out in the lower temperature. The minimum forward voltage at 20mA was obtained to be 4.8 V for LEDs with the p-GaN layer activated at $900^{\circ}C$ in the $N_2$ ambient and 4.5V for LEDs with the p-GaN layer treated at $700^{\circ}C$ in the $O_2$ambient, repectively. The forward voltage reduction of the LEDs treated in the $O_2$-ambient may be related to the oxygen co-doping of the p-GaN layer during the activation process. The $O_2$ -ambient activation process is useful for the enhancement of the LED performance as well as the fabrication process since this process can activate the Mg dopants in the low temperature.

동적응답을 최소화하는 비구속형 제진보의 제진부위 최적설계 (Optimal Treatment of Unconstrained Visco-elastic Damping Layer on Beam to Minimize Vibration Responses)

  • 이두호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.656-661
    • /
    • 2005
  • An optimization formulation of unconstrained damping treatment on beams is proposed to minimize vibration responses using a numerical search method. The fractional derivative model is combined with RUK's equivalent stiffness approach in order to represent nonlinearity of complex modulus of damping materials with frequency and temperature. The loss factors of partially covered unconstrained beam are calculated by the modal strain energy method. Vibration responses are calculated by using the modal superposition method, and of which design sensitivity formula with respect to damping layout is derived analytically. Plugging the sensitivity formula into optimization software, we can determine optimally damping treatment region that gives minimum forced response under a given boundary condition. A numerical example shows that the proposed method is very effective in minimizing vibration responses with unconstrained damping layer treatment.

  • PDF