• Title/Summary/Keyword: temperature minimum layer

Search Result 141, Processing Time 0.022 seconds

Year-to-year Variability of the Vertical Temperature Structure in the Youngsan Estuary

  • Cho, Yang-Ki;Lee, Kyeong-Sig;Park, Kyung-Yang
    • Ocean and Polar Research
    • /
    • v.31 no.3
    • /
    • pp.239-246
    • /
    • 2009
  • Long-term observations were conducted between 1997 and 2002 to examine the variability of the vertical temperature structure in the Youngsan Estuary, southwest Korea, in summer. The observed hydrographic data revealed that the temperature minimum layer in the middle depth persisted through the entire summer of 2000 but was rarely observed in other years. The variability in the vertical structure might be affected by the air temperature during the previous winter and the density difference between the open sea and the estuary. In 2000, the air temperature in the previous winter was lowest and the horizontal density difference during summer was largest. The large horizontal density difference probably produced more active driving of warm water along the bottom, which would have intruded into the Youngsan Estuary. Furthermore, the cold previous winter would have provided a better condition for maintaining cold temperatures in the middle water layer for a longer period.

Temperature Characteristics of Elastic Layer Mode Propagating on Piezoelectric Crystal (이층구조의 전반로를 갖는 단성표면파의 온도특성)

  • 김완상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.6
    • /
    • pp.56-61
    • /
    • 1973
  • The temperature coefficients and phase velocity dispersions of elastic surface wave layer mode with Ag or Pd layer on piezoelectric LiNbO3 svbstrate rotated 131$^{\circ}$ Y out are calculated as a function of thickness by numerical method. Calculated results are shown that the temperature coefficients are rapidly increased in proportion as the thickness of Ag layer increases. and irregular variation of the temperature coefficients appears in the case of Pd layer. Minimum value, -36$\times$10 /$^{\circ}C$, of the temperature coefficients of elastic surface wave with Pd layer on LiMbO3 substrate rotated 131$^{\circ}$ Y cut is obtained at wh=9000.

  • PDF

Effects of Surface Roughness and Thermal Treatment of Buffer Layer on the Quality of GaN Epitaxial Layers (Buffer layer의 표면 거칠기와 열처리조건이 GaN 에픽층의 품질에 미치는 영향)

  • 유충현;심형관;강문성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.564-569
    • /
    • 2002
  • Heteroepitaxial GaN films were grown on sapphire substrates in order to study the effects of the buffer layer's surface roughness and thermal treatment on the epitaxial layer's quality. For this, GaN buffer layers were grown at $550^{\circ}C$ with various TMGa flow rates and durations of growth, and annealed at $1010^{\circ}C$ for 3 min after the temperature was raised by 23 ~ $92^{\circ}C/min$, and then GaN epitaxial layers were grown at $1000^{\circ}C$. It has been found that the buffer layer's surface roughness and the thermal treatment condition are critical factors on the quality of the epitaxial layer. When a buffer layer was frown with a TMGa flow rate of $24\mu mole/min$ for 30 sec, the surface roughness of the buffer lather was minimum and when the thermal ramping rate was $30.6^{\circ}C/min$ on this layer, the successively grown epitaxial layer's crystalline and optical qualities were optimized with a specular morphology. The minimum full width at half maximum(FWHM) of GaN(0002) x-ray diffraction peak and that of near-band-edge(NBE) peak from a room temperature photoluminescence (PL) were 5 arcmin and 9 nm, respectively.

Physical Oceanographic Characteristics between Hawaii and Chuuk Observed in Summer of 2006 and 2007 (2006년과 2007년 여름에 관측한 Hawaii-Chuuk 사이의 물리특성)

  • Shin, Chang-Woong;Kim, Dong-Guk;Jeon, Dong-Chull;Kim, Eung
    • Ocean and Polar Research
    • /
    • v.33 no.spc3
    • /
    • pp.371-383
    • /
    • 2011
  • To investigate the physical characteristics and variations of oceanic parameters in the tropical central North Pacific, oceanographic surveys were carried out in summer of 2006 and 2007. The survey periods were classified by Oceanic Ni$\tilde{n}$o Index as a weak El Ni$\tilde{n}$o in 2006 and a medium La Ni$\tilde{n}$a in 2007. The survey instruments were used to acquire data on CTD (Conductivity Temperature and Depth), XBT (Expendable Bathythermograph), and TSG (Thermosalinograph). The dominant temporal variation of surface temperature was diurnal. The diurnal variation in 2007, when the La Ni$\tilde{n}$a weather pattern was in place, was stronger than that in 2006. Surface salinity in 2006 was affected by a northwestward branch of North Equatorial Current, which implies that the El Ni$\tilde{n}$o affects surface properties in the North Equatorial Current region. Two salinity minimum layers existed at stations east of Chuuk in both year's observations. The climatological vertical salinity section along $180^{\circ}E$ shows that the two salinity minimum layers exist in $2^{\circ}N{\sim}12^{\circ}N$ region, consistent with our observations. Analysis of isopycnal lines over the salinity section implies that the upper salinity minimum layer is from intrusion of the upper part of North Pacific Intermediate Water into the lower part of South Pacific Subtropical Surface Water and the lower salinity minimum layer is from Antarctic Intermediate Water.

Temperature History of Concrete at Cold Weather Depending on the Kinds of Insulating Sheet (단열양생시트 종류 변화에 따른 한중콘크리트의 온도이력)

  • Jeon, Chung-Keun;Kim, Jong;Shin, Dong-An;Oh, Seon-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.618-621
    • /
    • 2006
  • This paper is to investigate temperature history of cold weather concrete depending on insulation curing sheet kinds. Insulating effect according to curing sheet is shown in order of 5 layer bubble sheet, combination of PE form and 3 layer bubble sheet and 3 layer bubble sheet. It maintained above $10^{\circ}C$ of minimum temperature until the completion of initial curing period when bubble curing sheet was supplied regardless of curing sheet kinds. Five layer bubble curing sheet secure higher curing temperature than any other curing sheet applied in this experiment by as much as $2{\sim}3^{\circ}C$, which performed remarkable insulation effect. Concrete applied with curing sheet secured above $65^{\circ}D{\cdot}D$ of maturity, at which concrete had 5MPa of compressive strength at 3 days.

  • PDF

Characteristics of Temperature Variation in Urban and Suburban Areas During Winter (겨울철 도시지역과 교외지역의 기온변화 특성)

  • Kwon, Sung-Ill;Kim, Jin-Soo;Park, Jong-Hwa;Oh, Kwang-Young;Song, Chul-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.55-63
    • /
    • 2008
  • We investigated characteristics of temperature variation in urban and suburban areas(e.g., paddy field, upland, park, residential area) and urban heat island(UHI) during winter(December 2005 to February 2006). The daily maximum air temperature was not significantly different between suburban and urban areas, whereas the daily minimum air temperatures were significantly lower in the suburban areas than that in the residential area. The wind speed in the urban park(0.3 m/s) was much lower than that in the paddy fields(2.3 m/s), likely due to an urban canopy layer formed by high buildings. The UHI intensity was represented by differences in daily minimum temperatures between urban residential and paddy field areas. The UHI intensity($4.1^{\circ}C$) in winter was larger than that($2.6^{\circ}C$) in summer. This may be because a stable boundary layer develops in the winter, and thereby this inhibits diffusion of heat from surface.

Computational thermal stability and critical temperature buckling of nanosystem

  • Chengda Zhang;Haifeng Hu;Qiang Ma;Ning Wang
    • Advances in nano research
    • /
    • v.14 no.6
    • /
    • pp.575-590
    • /
    • 2023
  • Many of small-scale devices should be designed to tolerate high temperature changes. In the present study, the states of buckling and stability of nano-scale cylindrical shell structure integrated with piezoelectric layer under various thermal and electrical external loadings are scrutinized. In this regard, a multi-layer composite shell reinforced with graphene nano-platelets (GNP) having different patterns of layer configurations is modeled. An outer layer of piezoelectric material receiving external voltage is also attached to the cylindrical shell for the aim of observing the effects of voltage on the thermal buckling condition. The cylindrical shell is mathematically modeled with first-order shear deformation theory (FSDT). Linear elasticity relationship with constant thermal expansion coefficient is used to extract the relationship between stress and strain components. Moreover, minimum virtual work, including the work of the piezoelectric layer, is engaged to derive equations of motion. The derived equations are solved using numerical method to find out the effects of temperature and external voltage on the buckling stability of the shell structure. It is revealed that the boundary condition, external voltage and geometrical parameter of the shell structure have notable effects on the temperature rise required for initiating instability in the cylindrical shell structure.

Temperature History of Slab Concrete Depending on Insulation Curing Method in Cold Weather Concreting (한중시공시 단열양생방법 변화에 따른 슬래브 콘크리트의 온도이력 특성)

  • Kim Jong-Back;Lim Choon-Goun;Park Koo-Byoung;Kim Seoung-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.17-20
    • /
    • 2005
  • This paper reported the temperature history of concrete placed at deck plate slab under cold climate condition by varying with surface insulating type. No curing sheet and simple insulation curing including non-woven fabric, double layer bubble sheet, the combination of double layer bubble sheet and non-woven fabric dropped temperature below zero within 24 hours, which caused frost damage at early age. On the other hand, the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam maintained minimum temperature above $4^{\circ}C\;and\;8^{\circ}C$, respectively. Based on core test results compressive strength of concrete with the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam was higher than those with other curing method due to good insulation effect.

  • PDF

Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area (부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

The Experimental Study of the Interaction Between the Flow rind Temperature Field and a Boundary Layer Due to a Variety of tole Height of a Vortex Generator (와동 발생기 높이 변화에 대한 경계층 내의 유동장과 온도장에 관한 실험적 연구)

  • Gwon, Su-In;Yang, Jang-Sik;Lee, Gi-Baek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.82-93
    • /
    • 2002
  • The effects of the interaction between the flow and temperature field and a boundary layer due to a variety of the height of a vortex generator are experimentally investigated. The test facility consists of a boundary-layer wind tunnel with the vortex generator protruding from the bottom surface. In order to control the strength of the longitudinal vortices, the angle of attack and the spacing distance of the vortex generator are 20 degree and 40 mm, respectively. The height of the vortex generator (H) is 15 mm, 20 mm and 30 mm and the cord length of it is 50 mm. Three-component mean velocity measurements are made using a 5-hole probe system and the surface temperature distribution is measured by the hue capturing method using thermochromatic liquid crystals. By using the method mentioned above, the following conclusions are obtained from the present experiment. The boundary layer is thinned in the downwash region where the strong downflow and the lateral outflow of the boundary layer fluid occur and thickened in the upwash re,3ion where the longitudinal vortex sweeps low momentum fluid away from the bottom surface. In case that the height of the vortex generator increases, the averaged circulation and the maximum vorticity of the vortex pair decrease. The contours of the non-dimensional temperature show the similar trends fur all the cases (H=15 mm, 20 mm and 30 mm). The peak augmentation of the distribution of the local non-dimensional temperature occurs in the downwash region near the point of minimum boundary-layer thickness.