• Title/Summary/Keyword: temperature fluctuation

Search Result 634, Processing Time 0.128 seconds

Change in Quality of Frozen Breaded Raw Shrimp by Storage Temperature Fluctuation (빵가루 입힌 냉동새우의 동결저장중 온도변동에 의한 품질변화)

  • Jeong, Jin-Woong;Jo, Jin-Ho;Lim, Sang-Dong;Kang, Tong-Sam
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.532-537
    • /
    • 1991
  • Effect of storage temperature fluctuation on quality of frozen breaded raw shrimp was studied. Storage experiments were undertaken as follows; First, after storage at $-20^{\circ}C$ for 20 days or 40 days, storage temperature of materials were raised to $-15^{\circ}C\;or\;15^{\circ}C$, and then stored at these temperatures, And second, by repeating for 5, 10 and 15 times by 3 conditions ($-20{\rightarrow}-15^{\circ}C{\rightarrow}-20^{\circ}C,\;-20{\rightarrow}-10^{\circ}C{\rightarrow}-20^{\circ}C\;-20{\rightarrow}-5^{\circ}C{\rightarrow}-20^{\circ}C$) with temperature fluctuation during storage. Quality changes were measured by determining extractability of salt-soluble protein, volatile basic nitrogen, thiobar-bituric acid, pH and microbiological changes at regular intervals. Rise in storage temperature from $-20^{\circ}C\;to\;-15^{\circ}C$ had not caused significant change on it's quality, but rise up to $-5^{\circ}C$ caused some change in quality without relationship with storage period before temperature rise. Fluctuation of storage temperature from $-20^{\circ}C\;to\;-15^{\circ}C$ of frozen breaded raw shrimp did not cause noticeable changes on it's quality. But temperature fluctuation from $-20^{\circ}C\;to\;-10^{\circ}C\;or\;-5^{\circ}C$ caused remarkable changes of it's quality, according to the increase of fluctuation times and temperatures.

  • PDF

A Study on High Cycle Temperature Fluctuation Caused by Thermal Striping in a Mixing Tee Pipe (혼합배관 내의 열 경계층 이동으로 인한 고주기 온도요동에 관한 연구)

  • Kim, Seoug-B.;Park, Jong-H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.9-19
    • /
    • 2007
  • Fluid temperature fluctuations in a mixing tee pipe were numerically analyzed by LES model in order to clarify internal turbulent flows and to develope an evaluation method for high-cycle thermal fatigue. Hot and cold water with an temperature difference $40^{\circ}C$ were supplied to the mixing tee. Fluid temperature fluctuations in a mixing tee pipe is analysed by using the computational fluid dynamics code, FLUENT, Temperature fluctuations of the fluid and pipe wall measured as the velocity ratio of the flow in the branch pipe to that in the main pipe was varied from 0.05 to 5.0. The power spectrum method was used to evaluate the heat transfer coefficient. The fluid temperature characteristics were dependent on the velocity ratio, rather than the absolute value of the flow velocity. Large fluid temperature fluctuations were occurred near the mixing tee, and the fluctuation temperature frequency was random. The ratios of the measured heat transfer coefficient to that evaluated by Dittus-Boelter's empirical equation were independent of the velocity ratio, The multiplier ratios were about from 4 to 6.

ESTABLISHMENT OF A NEURAL NETWORK MODEL FOR DETECTING A PARTIAL FLOW BLOCKAGE IN AN ASSEMBLY OF A LIQUID METAL REACTOR

  • Seong, Seung-Hwan;Jeong, Hae-Yong;Hur, Seop;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • A partial flow blockage in an assembly of a liquid metal reactor could result in a cooling deficiency of the core. To develop a partial blockage detection system, we have studied the changes of the temperature fluctuation characteristics in the upper plenum according to changes of the t10w blockage conditions in an assembly. We analyzed the temperature fluctuation in the upper plenum with the Large Eddy Simulation (LES) turbulence model in the CFX code and evaluated its statistical parameters. Based on the results of the statistical analyses, we developed a neural network model for detecting a partial flow blockage in an assembly. The neural network model can retrieve the size and the location of a flow blockage in an assembly from a change of the root mean square, the standard deviation, and the skewness in the temperature fluctuation data. The neural network model was found to be a possible alternative by which to identify a flow blockage in an assembly of a liquid metal reactor through learning and validating various flow blockage conditions.

The Study on the Physiological Response in Wearing Sportswear in Two Different Environments

  • Kwon, Oh Kyung;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.416-422
    • /
    • 2000
  • In this study, to find out the physiological reaction of the human body and the sensation of comfort when people are wearing sportswear which is made of waterproof breathable fabrics under general environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec) and rainy environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec, rainfall : 250 1/hr), we made an experiment with sportswear in an artificial climate chamber and studied the thermal physiological response and subjective sensation. Mean skin temperature of the subjects was low and had a big range of fluctuation in rainy environmental conditions of two condition. Temperature started to increase at the beginning of the exercise, reached the maximum at the 2nd level of the exercise and then started to decline. Rectal temperature showed a slighter increase and bigger range of fluctuation in general conditions than in rainy conditions. Except clothing micro climate in rainy conditions, temperature and humidity and their range of fluctuation around back were higher than those around chest. Humidity was high and had wide range of fluctuation in general conditions. Heart rate was 4.4 beats/min higher in general conditions. In subjective test on rainy conditions, the feeling of discomfort increased due to the raindrops fallen on the skin. Unlike that in general conditions, cold sensation increased and humidity sensation reached to the peak after the exercise. In wearing sportswear made of shape memory breathable waterproof fabric, controlling function over a small amount of heat and water was distinctive while it turned out to be not so comfortable over a large amount of heat and water. Through this, the limitation of shape memory breathable waterproof fabric was recognised.

  • PDF

The Investigations of the Characteristics of Unsteady Piston Temperature Using Radiotracers-The Effect of Piston Ring Gap Position and Blow By Gas (방사성 추적자를 이용한 피스톤의 비정상 온도 특성에 관한 연구 -피스톤 링 갭 위치와 블로우 바이 가스의 영향-)

  • 김중수;김승일;민병순;박승일;오대윤;정성희;진준하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.1-9
    • /
    • 2000
  • To understand the thermal characteristics around the piston ring gap ring gap positions and piston temperatures are measured simultaneously. The locations of piston ring gap are measured by the radio-tracer method and piston temperature are measured by a K-type thermocouple and scissors type linkage system. From these experiments following facts are clarified. Piston temperatures fluctuate according to the piston ring rotation. And the temperature fluctuation is mainly affected by top ring gap position irrelevant to the second ring fop position. If the top ring gap position increases and the temperature of top ring groove shows maximum value when top rin gap position coincide with temperature measuring point. The maximum amplitude of temperature fluctuation which is proportional to the blow by gas rate is around 12-15$^{\circ}C$.

  • PDF

Plant Hardiness Zone Map in Korea and an Analysis of the Distribution of Evergreen Trees in Zone 7b

  • Suh, Jung Nam;Kang, Yun-Im;Choi, Youn Jung;Seo, Kyung Hye;Kim, Yong Hyun
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.5
    • /
    • pp.519-527
    • /
    • 2021
  • Background and objective: This study was conducted to establish a Plant Hardiness Zone (PHZ) map, investigate the effect of global warming on changes in PHZ, and elucidate the difference in the distribution of evergreen trees between the central and southern region within hardiness Zone 7b in Korea. Methods: Mean annual extreme minimum temperature (EMT) and related temperature fluctuation data for 40 years (1981 to 2020) in each of the meteorological observation points were extracted from the Open MET Data Portal of the Korea Meteorological Administration. Using EMT data from 60 meteorological observation points, PHZs were classified according to temperature range in the USDA Plant Hardiness Zone Map. Changes in PHZs for each decade related to the effects of global warming were analyzed. Temperature fluctuation before and after the day of EMT were analyzed for 4 areas of Seoul, Suwon, Suncheon, and Jinju falling under Zone 7b. For statistical analysis, descriptive statistics and ANOVA were performed using the IBM SPSS 22 Statistics software package. Results: Plant hardiness zones in Korea ranged from 6a to 9b. Over four decades, changes to warmer PHZ occurred in 10 areas, especially in colder ones. Based on the analysis of daily temperature fluctuation, the duration of sub-zero temperatures was at least 2 days in Seoul and Suwon, while daily maximum temperatures were above zero in Suncheon and Jinju before and after EMT day. Conclusion: It was found that the duration of sub-zero temperatures in a given area is an important factor affecting the distribution of evergreen trees in PHZ 7b.

Instability of a Two-Phase Loop Thermosyphon

  • Rhi, Seok-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.1019-1028
    • /
    • 2002
  • The instability of two-phase loop thermosyphons was investigated experimentally and analytically. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7 mm (no insert) to 0.71 mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT. With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT The analysis based on the Kelvin-Helmholtz instability theory seems to predict reasonable well the loop stability state of the TLT with experimentally determined constant factors.

Experimental Study on Instability of Two-Phase Loop Thermosyphon (루프형 2상 유동 열사이폰의 유동 불안정에 관한 실험적 연구)

  • 이석호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.408-414
    • /
    • 2002
  • The instability of two-phase loop thermosyphons (TLTs) was investigated experimentally. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7mm (no insert) to 0.71mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT.

Transient fluid temperature fluctuation in boiling (푸울 沸騰時 過渡的 流體溫度 變動)

  • 김종일;정충식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.44-47
    • /
    • 1988
  • The present experiments of transient temperature variation and temperature fluctuation were conducted by bead type thermistors in pool boiling without a heat surface. The experimentally obtained conclusion were as follows. (1) The high transient temperature Variatian of 11.64.deg. C for a duration of 0.08 sec and a temperature freguency having a duration of 5.6*10$^{-2}$ sec in a flashing were measured. (2) The highest variation of transient temperature was shown at saturated temperature of 80.deg. C and superheat of 7.9.deg. C. (3) Temperature frequency was found to increase with superheat below 60.deg. C of saturated temperature, but above 60.deg. C it was relative to lower superheat and was found to decrease with higher superheat..

A Study on the Condenser Temperature Characteristics of a Disk Type Heat Pipe (원판형 히트파이프의 응축부 온도 특성에 관한 실험적 연구)

  • Boo, Joon-Hong;Chung, Won-Bok;Kim, Tae-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.148-153
    • /
    • 2000
  • An experimental study was conducted to investigate an isothermal characteristics of the condenser surface of disk type heat pipe using PF 5060 and FC 40 as working fluids. Desired temperature range at the condenser surface was $90^{\circ}C{\sim}130^{\circ}C$, which was cooled by natural convection. The operating temperature, the height of vapor space, the wall thickness of condenser, and the existence of a wick structure were considered as experimental factors. The temperature difference and the temperature fluctuation at the condenser surface were analysed to describe the performance of the heat pipe.

  • PDF