• Title/Summary/Keyword: temperature field

Search Result 6,551, Processing Time 0.036 seconds

Field Induced Phase Transition in $0.6Pb(Ni_{1/3}Nb_{2/3})O_3-0.31PbTiO_3-0.09PbZrO_3$ Relaxor Ferroelectrics ($0.6Pb(Ni_{1/3}Nb_{2/3})O_3-0.31PbTiO_3-0.09PbZrO_3$ 완화형 강유전체의 전계 유기 상전이 현상)

  • 윤만순;장현명;정회승;최병철
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.6
    • /
    • pp.620-628
    • /
    • 1997
  • The possibility of the existence of a field-induced micro-macrodomain switching was proposed and examined using 9 mol % PbZrO3-doped 0.6Pb(Ni1/3Nb2/3)O3-PbTiO3 (PNN-PT) systems having rhombohedral symmetry at room temperature. the thermally depoled (freshly prepard) specimens prepared from the rhombohedral side of the system exhibited a relaxor behavior for the whole range of temperature examined (for T

  • PDF

Distributions of Hyperfine Parameters in Amorphous $Fe_{83}B_9Nb_7Cu_1$ Alloys (비정질 $Fe_{83}B_9Nb_7Cu_1$의 M$\)

  • 윤성현;김성백;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.271-277
    • /
    • 1999
  • Amorphous $Fe_{83}B_9Nb_7Cu_1$ alloy has been studied by M$\"{o}$ssbauer spectroscopy. Revised Vincze method was used and distributions of hyperfine field, isomer shift, and quadrupole line broadening of the sample at various temperatures have been evaluated and Curie temperature and $H_{hf}\;(0)$ were calculated to be 393 K and 231 kOe, respectively. Temperature variation of reduced average hyperfine field shows a flattered curvein comparison with the Brillouin curve for S=1. This behavior can be explained on the basis of Handrich molecular field model, in which the parameter Δ, which is a measure of fluctuation in exchange interactions, is assumed to have the temperature dependence ${Delta}=0.75-0.64{\tau}+0.47{\tau}^2$ where $\tau$ is $T/T_C$. At low temperature, the average hyperfine field can be fitted to $H_{hf}\;(T)=H_{hf}\;(0)\;[1-0.44\;(T/T_C)^{3/2}-0.28(T/T_C)^{5/2}-… ]$, which indicates the presence long wave length spin wave excitations. At temperature near TC, reduced average hyperfine field varies as $1.00\;[1-T/T_C]^{0.39}$. It is also found that half-width of the hyperfine field distribution was 102 kOe (3.29 mm/s) at 13 K and decreased monotonically as temperature increased. Above the Curie temperature, an average quadrupole splitting value of 0.43 mm/s was found. Average line broadening due to quadrupole splitting distribution was 0.31 mm/s at 13 K and decreases monotonically to 0.23 mm/s at 320 K, whereas that due to the isomer shift distribution is 0.1 mm/s at 13 K and 0.072 mm/s at 320 K, which is much smaller than that of both hyperfine field and quadrupole splitting. The temperature dependence of the isomer shift can be fitted within the harmonic approximation to a Deybe model with a Debye temperature ${Theta}_D=424{\pm}5K$.TEX>.

  • PDF

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

  • Chae, Yoon Seok;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.1-6
    • /
    • 2020
  • This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 W HTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

Magnetic $T_c$ Measurements of Composite Superconductors for a Standard Method (복합초전도체의 자기적 임계온도 측정의 표준화연구)

  • Lee K. W;Kim M. S;Kim D. H;Lee S. G
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • Magnetic $T_{c}$ of composite superconductors has been studied for providing a standard method. Various magnetization-temperature curves of NbTi, $Nb_3$Sn and Bi-2223 wires were measured using a SQUID magnetometer. Magnetization-temperature curve of zero-field-cooled procedure showed larger values than fie Id-cooled procedure. To obtain higher resolution near the onset temperature, we employed a two-field-direction method which measures a magnetization-temperature curve of a specimen first in positive and then negative fields. Analytical comparison of the magnetic $T_{c}$, with the resistive T$_{c}$ was accomplished for three specimens. The magnetic $T_{c}$/ mettled showed more detailed information on superconducting state of a specimen than the resistive$T_{c}$/ method. We have also studied the field dependence of the magnetic $T_{c}$ from 5 Oe to 120 Oe, however, no significant difference on field strength was found in our three specimensns

  • PDF

A Study of the Effects of Process Variables on Temperature and Magnetic-flux Distribution in Induction Heating of Steel Plate (강판의 유도가열에서 공정변수가 온도 및 자속분포에 미치는 영향에 관한 연구)

  • 배강열;이태환;양영수
    • Journal of Welding and Joining
    • /
    • v.19 no.5
    • /
    • pp.526-533
    • /
    • 2001
  • Induction heating of float metal products has an increasing importance in many applications, because it generates the heat within workpiece itself and provides high power densities and productivity. In this study, the induction heating of a steel plate to simulate the line heating is investigated by means of the Finite Element Analysis of the magnetic field and temperature distribution. A numerical model is used to calculate temperature distribution within the steel plate during the induction heating with a specially designed inductor. The effects of materital properties depending on the temperature and magnetic field are taken into consideration in an iterative manner. The simulation results show good magnetic field with experimental data and provide good understanding of the process. Since the numerical model demonstrates to be suitable for analysis of induction heating process, the effects of air gap and frequency on magnetic-flux and power-density distribution are also investigated. It is revealed that these process parameters have an important roles on the electro-magnetic field and power-density distribution governing the temperature distribution of the plate.

  • PDF

A Study on Non-contact Surface Temperature Field Measurement of a Body Immerged in Water Using Thermographic Phosphor Thermometry (열감지인광온도계를 이용한 물에 잠긴 물체 표면 온도장의 비접촉식 측정에 관한 연구)

  • Park, Yoonseong;Cai, Tao;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • Thermographic phosphor (TP) thermometry is a noncontact optical measurement method and has been applied in many fields such as combustion and heat transfer. However, due to the limitation of bonding technology and measurement method, most TP thermometry studies were conducted only on the air environment with water-soluble binders. In this paper, a temperature measurement technology in water using TP is proposed by coatings of manganese activated magnesium fluorogermanate (Mg4FGeO6:Mn4+, MFG) with Polydimethylsiloxane (PDMS). Four MFG-PDMS coatings with different thicknesses were prepared. The lifetime of MFG was not affected by the thickness of the coating as a result of the experiment and analysis of phosphor intensity using a photomultiplier tube. To measure the surface temperature field of an immerged body in water, a cylinder-type cartridge heater was coated with MFG doped PDMS. Transient surface temperature field was successfully measured even the initial temperature is higher than the boiling point of water.

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

Design of Field Coil for High Temperature Superconducting motor considering Operating Current (운전전류를 고려한 고온초전도 모터용 계자코일의 설계)

  • 조영식;서무교;백승규;김석환;손명환;권영길;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.315-317
    • /
    • 2002
  • The value of I$_{c}$(critical current) in HTS (High Temperature Superconducting) tape has a great influence on B(equation omitted) (magnetic field amplitude applied perpendicular to the tape surface). Therefore, I$_{c}$ of HTS magnet is determined by not only operating temperature but also the B(equation omitted). In shape design of field coil for the HTS motor, a method to reduce the B(equation omitted) and to determine operating current should be considered in order to optimal design. On the basis of the magnetic field analysis, this paper deals with various field coil shape to obtain operating current of HTS motor by using analytical method. And also this paper discusses the operating current of 100hp class HTS motor by using I$_{c}$-B(equation omitted) curve.curve.

  • PDF

The Domestic Development of a Superconducting MRI Magnet (초전도 MRI 마그네트 국산화 개발)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation (수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.