• 제목/요약/키워드: temperature field

검색결과 6,551건 처리시간 0.036초

FLOW AND TEMPERATURE ANALYSIS WITHIN AUTOMOBILE CABIN BY DISCHARGED HOT AIR FROM DEFROST NOZZLE

  • Park, W.G.;Park, M.S.;Jang, K.L.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.139-143
    • /
    • 2006
  • As an automobile tends to be high grade, the needs for more luxurious interior and comfortable HVAC system are emerged. The defrosting ability is another major factor of the performances of HVAC system. The present work is to simulate the flow and the temperature field of cabin interior during the defrost mode. The three-dimensional incompressible Navier-Stokes equations and energy equation were solved on the multi blocked grid system by the iterative time marching method and AF scheme, respectively. The present computations were validated by the comparison of the temperature field of a driven cavity and velocity field of 1/5 model scale of an automobile. Generally good agreements were obtained. By the present computation, the complicated features of flow and temperature within the automotive cabin interior could be well understood.

Analysis and research on teeth thermodynamic coupling contact of gear transmission system

  • Wang, Xigui;Wang, Yongmei;Zhao, Xuezeng;Li, Xinglin
    • Coupled systems mechanics
    • /
    • 제4권3호
    • /
    • pp.237-249
    • /
    • 2015
  • In the gear meshing process, gear temperature field concerns the meshing surface friction, the friction heat depends on the contact pressure, the contact pressure is affected by the elastic deformation of gears and the temperature field caused by the thermal deformation, so the temperature field, stress field and displacement field should be mutual coupling. It is necessary to consider in meshing gear pair in the operation process of thermodynamic coupling contact stress (TCCS) and thermodynamic coupling deformation (TCD), and based on thermodynamic coupling analysis (TCA) of gear teeth deformation.

재활용 가능한 폴리에틸렌과 폴리프로필렌의 전도도 온도의존성과 전력케이블 내의 전계분포에 미치는 영향 (Temperature Dependence of Conductivities of Recyclable Polyethylene and Polypropylene and its Effects on Electric Field Distribution in Power Cable)

  • 이준호;공태식;김성중;권기형;조규철;호즈미 나오히로
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1881-1887
    • /
    • 2011
  • In this work the recyclable new polyethylene(PE) and polypropylene(PP), which are thermoplastic, have been investigated as the eco-friendly insulating candidates to replace the cross-linked polyethylene (XLPE). The temperature dependence of conductivities of these materials has been measured and its effects on electric field and space charge distribution in polymeric insulated power cable under temperature gradient have been calculated. It is shown that the sensitivity of conductivity to temperature change has more critical influence to determine the electric field distribution in the power cable than the absolute value of conductivity does and it can be said that the temperature dependence is one of most important factors for the power cable design.

현장계측 및 수치해석에 의한 장대버팀보의 온도영향 분석 (The Analysis of the Temperature Effects on Long-span Strut by Field Monitoring and Numerical Analysis)

  • 이문주;최성근;신세영;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1468-1475
    • /
    • 2005
  • In this study, the effects of temperature on loading of long-span strut were studied by using field monitoring and numerical analysis. For the field monitoring, several sensors, such as stain gages, temperature gages and load cells, were installed on the struts. From the monitoring results, the relation between temperature and axial force of the struts was analysed. By numerical analysis, the changes of axial force of strut and lateral displacement of wall due to temperature change were described with the strut length and ground conditions.

  • PDF

VDF/TrFE 공중합체의 히스테리시스 및 온도특성 (A study on hysteresis and temperature properties of VDF/TrFe copolymer)

  • 방태찬;김종경;강대하
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권2호
    • /
    • pp.156-165
    • /
    • 1997
  • D-E hysteresis loops have been measured for the 65/35 mole % copolymer of vinylidene fluoride and trifluoroethylene over wide temperature range. The remanent polarization and the coercive field at room temperature were estimated to be 75 mC/m$^{2}$ and 55 MV/m respectively. D-E hysteresis loops were observed even below the glass transition temperature(-20.deg. C) and the remanent polarization and the coercive field were larger, as the temperature lower. It seems that the remanent polarization and the coercive field depend on the amorphous region as well as crystalline region in this copolymer. And the ferroelectric-to-paraelectric phase transition was observed at 90.deg. C on heating and 80'C on cooling. Double hysteresis loops were observed at the temperature(85.deg. C) of paraelectric phase.

  • PDF

Numerical Calculation Study on the Generalized Electron Emission Phenomenon

  • Kim, Hee-Tae;Yu, Soon-Jae
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.158-163
    • /
    • 2009
  • There are two kinds of well-known electron emissions from metal: field and thermionic emission. For thermionic emission, electrons come out of a metal due to the thermal energy, whereas for field emission, electrons tunnel out of a metal through the strong electric field. In this study, the most general electron emission caused by the temperature and electric field with a free electron gas model was considered. The total current density of electron emission comes from the field emission effect, where the electron energy is lower than vacuum, and from the thermionic-emission effect, where the electron energy is higher than vacuum. The total current density of electron emission is shown as a function of the temperature for a constant electric field, and as a function of the electric field for a constant temperature.

미나리 작업자를 위한 작업복 개발에 관한 연구 (Development the protective clothing for a dropworts cropping workers)

  • 최정화;백윤정
    • 한국의류학회지
    • /
    • 제24권8호
    • /
    • pp.1266-1275
    • /
    • 2000
  • This study was to research the actual condition of a dropworts working environment and to develope the clothing to reduce the work road. The actual conditions of working environment, working position and clothing were surveyed. Experiments were performed in the chamber and in the field. In the chamber, rectal temperature, 11 points skin temperatures(forehead, chest, abdomen, upperarm, forearm, dorsum manus, palm, thigh, calf, dorsum pedis and pelma), heart rates, microclimates inside clothing on the chest and subjective sensations were measured for comparing between 2 different types o garments. In the field, rectal temperature, abodomen skin temperature, 3 points microclimates inside clothing(chest, back and thigh), heart rates, the volume of EMG and subjective sensations were measured. The results were as follows; 1. There were no significant differences in rectal temperature between a old type protective clothing and a new type both in the chamber and the field. 2. Subjects wearing a old type clothing responded \"a little cold\", \"a little uncomfortable\" and subjects wearing a new type protective clothing responded \"normal\", \"comfortable\" both in the chamber and the field. 3. In the field test results, abodemen skin temperature in a old type clothing was higher and microtemperatures inside clothing of chest, back and thigh in a new type protective clothing were higher. 4. The volume of EMG was lower in the new type protective clothing than in the old one.protective clothing than in the old one.

  • PDF

偏心된 二重圓管의 環狀部를 지니는 層流流動에서의 連度場 및 溫度場의 確立에 대한 硏究 (A study on the development of the velocity and temperature fields in a laminar flow through an eccentric annular ducts)

  • 이택식;이상산
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.861-869
    • /
    • 1986
  • 본 연구에서는 동시확립문제의 속도장해석에 있어서 단면내의 속도분포에 대 한 일체의 가정을 하지 않고 운동량방정식을 직접 해석하여 단면내의 속도분포를 구하 였다. 또한 Prandtl수, 반경비 및 편심도가 열전달특성에 미치는 영향에 대한 해석 도 수행하였다.

여름철 토지피복별 기온변화 특성 (Characteristics of Air Temperature Variations under Different Land Covers during Summer)

  • 김진수;박종화;정구영;오광영
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.79-88
    • /
    • 2007
  • We investigated the characteristics of temperature variations under different land covers (paddy field, upland, urban park, and urban residential area) during hot summer (July 15 to August 19, 2005). The temperatures were monitored using data loggers at one hour intervals in study sites. The mean temperature generally increased with the distance from edge of paddy fields, being $1.5^{\circ}C$ higher at a site 170-m far from paddy fields than at a paddy field area at 22 h. The mean daily temperatures in the study period followed the ordo. of paddy field $(26.6^{\circ}C)$ < upland $(27.0^{\circ}C)$ < park $(27.5^{\circ}C)$ < residential area $(28.0^{\circ}C)$. The paddy field area has shown remarkable cooling effects compared to the residential area: Mean duration of temperature below $25^{\circ}C$ in the paddy field area was longer (8.6 hrs) than in the residential area; The time to fall to below $25^{\circ}C$ in the paddy field area was sooner (22.4 hr) than in the residential area; Mean daily minimum temperature in the paddy field area was much lower $(2.4^{\circ}C)$ than in the residential area. More research is needed to better clarify the mechanism of cooling effect of a paddy field area by investigating heat balance of a paddy field.

완화형 가유전체에서 전계인가에 따른 격자왜곡과 강유전물성의 상관관계 (Electric-Field-Induced Lattice Distortion and Related Properties in Relaxor Ferroelectrics)

  • 박재환;박재관;김윤호
    • 한국결정학회지
    • /
    • 제12권1호
    • /
    • pp.14-19
    • /
    • 2001
  • Effects of electric-field-induced lattice distortion on the polarization and strain were investigated in Pb(Mg/sub 1/3/Nb/sub 2/3)O₃ relaxor ferroelectric ceramics in the temperature range of -50℃∼90℃. The ratio of residual strain and polarization (S/sub r//P/sub r/ rarely depends on the temperature. However, the ratio of the electric field included strain and polarization (S/sub induced//P/sub induced/) increased as the temperature decreases below phase transition temperature. To explain these experimental results, a simple rigid ion model concentrating on only Bo/sub 6/ octahedron was suggested.

  • PDF