• Title/Summary/Keyword: temperature field

검색결과 6,579건 처리시간 0.038초

Design of Alternating Magnetic Field Stimulator Using Duty Factor

  • Jang, Tae-Sun;Lee, Jin-Yong;Lee, Hyun-Sook;Kim, Sun-Wook;Hwang, Do-Guwn
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.42-45
    • /
    • 2012
  • We have developed an alternating magnetic field stimulation system consisting of a switched-mode power supply and a digital control circuit which modulates a duty ratio to maintain a magnetic field intensity of a few mT even while the frequency increases up to 4 kHz with a controllable coil temperature below $30^{\circ}C$ in air. This duty ratio modulation and water circulation are advantageous for cell culture under ac-magnetic field stimulation by preventing the incubator from exceeding a cell-viable temperature of $37^{\circ}C$. Although the temperature of the coil when subjected to a sinusoidal voltage rapidly increased, that of our system modulated by the duty factor did not change. This is a potentially valuable method to investigate the effects of intermediate frequency magnetic field stimulation on biological entities such as cells, tissues and organs.

Study on the shape design of field coil in HTS generator considering stress condition

  • Jo, Young-Sik;Lee, Ju-Min;Hong, Jung-Pyo;Lee, Ju;Sohn, Myung-Hwan;Kwon, Young-Kil;Ryu, Kang-Sik
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.257-261
    • /
    • 2000
  • The value of I$_c$(critical current) in HTS (High Temperature Superconductor) tape has a great influence on B${\bot}$(vertical field). Therefore, in shape design of field coil for the HTSG(High Temperature Superconducting Generator), a method to reduce the B${\bot}$ should be considered in order to maintain the stability and substantial improvement on the performance. On the basis of the magnetic field analysis, this paper deals with various field coil shape according to the iron plate to obtain small B${\bot}$ by using Biot-Savart's law, image method and 2D FEA(2 Dimensional Finite Element Analysis) considering the stress condition of HTS. Moreover, the analysis is verified by comparison with experimental results. And also this paper presents the advanced model by using 3D FEA, in which flux density at armature is calculated in 5kVA class HTSG.

  • PDF

중자장급 보급형 국산 초전도 MRI 마그네트 개발 (The Development of Popular type Domestic Superconducting MRI Magnet with Middle Magnetic Field Range)

  • 배준한;고락길;심기덕;진흥범;조전욱;이언용;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.22-25
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

Trapped Field Analysis of a High Temperature Superconducting Bulk with Artificial Holes

  • Jang, Guneik;Lee, Man-Soo;Han, Seung-Yong;Kim, Chan-Joong;Han, Young-Hee;Park, Byung-Joon
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.181-185
    • /
    • 2011
  • To improve trapped field characteristics of a high temperature superconducting (HTS) bulk, a technique to implement artificial holes has been studied. The artificial holes, filled up with epoxy or metal, may provide better cooling channel and enhance mechanical strength of the HTS bulk. Although many useful researches based on experiments have been reported, a numerical approach is still limited because of several reasons that include: 1) highly non-linear electromagnetic properties of HTS; and 2) difficulty in modeling of randomly scattered "small" artificial holes. In this paper, a 2-D finite element method with iteration is adopted to analyze trapped field characteristics of HTS bulk with artificial holes. The validity of the calculation is verified by comparison between measurement and calculation of a trapped field in a $40{\times}40\;mm$ square and 3.1 mm thick HTS bulk having 16 artificial holes with diameter of 0.7 mm. The effects of sizes and array patterns of artificial holes on distribution of trapped field within HTS bulk are numerically investigated using suggested method.

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

$\textrm{0.9Pb}\textrm({Mg}_{1/3}\textrm{Nb}_{2/3})\textrm{O}_3$-$\textrm{0.1PbTiO}_3$계 강유전체에서 전계인가에 따른 분극 및 변위의 상관관계 (Correlations between the Polarization and Strain Induced by Electric field in $\textrm{0.9Pb}\textrm({Mg}_{1/3}\textrm{Nb}_{2/3})\textrm{O}_3$-$\textrm{0.1PbTiO}_3$ Relaxor Ferroelectrics)

  • 박재환;박재관;박순자
    • 한국재료학회지
    • /
    • 제9권1호
    • /
    • pp.81-85
    • /
    • 1999
  • Polarization and strain induced by unipolar electric field (P\ulcorner, S\ulcorner), those induced by bipolar electric field (P, S) and remanent polarization (P\ulcorner) were investigated in 0.9Pb(Mg\ulcornerNb\ulcorner)O$_3$-$0.1PbTiO_3$relaxor ferroelectric ceramics in the temperature range of $-50^{\circ}C$~$90^{\circ}C$. From the temperature dependence of polarization and strain, the transition from predominantly paraelectric (electrostrictive) to partially ferroelectric (piezoelectric) is visualized. Under the given temperature, the P\ulcorner/P\ulcorner is always larger than the S\ulcorner/S\ulcorner and the difference between them becomes larger ass the temperature decrease. The S\ulcorner/P\ulcorner increases as the temperature decreased below phase transition temperature. It was suggested that these experimental results might be explained with a simple rigid ion model concentrating on BO\ulcorner octahedron.

  • PDF

(Bi0.5Na0.5)TiO3 세라믹스의 유전 및 전기열량 특성 (Electrocaloric Effect of (Bi0.5Na0.5)TiO3 Ceramics)

  • 한종대;류주현;정영호
    • 한국전기전자재료학회논문지
    • /
    • 제30권5호
    • /
    • pp.284-287
    • /
    • 2017
  • The electrocaloric effect in $0.94(Bi_{0.5}Na_{0.5})TiO_3+0.06KNbO3+0.9wt%$ G.F.ferroelectricceramics was observed in terms of the temperature change (${\Delta}T$) of the fabricated ceramics, Curie temperature $T_c$, and applied electric field. The specimens were fabricated by a conventional solid-state reaction. $T_c$ appeared near $165{\sim}170^{\circ}C$. The P-E hysteresis showed a tendency to slim down with a temperature increase and finally was slimmest near $150^{\circ}C$. With the increase of temperature, the polarization revealed a gradual decrease, and a sharp decline near $T_c$. When an electric field of 45 kV/cm was applied, the largest polarization was shown. The maximum value of the temperature change (${\Delta}T=0.31^{\circ}C$) was obtained at $165^{\circ}C$ under an applied electric field of 45 kV/cm.

Prediction and Measurement of Residual Stresses in Injection Molded Parts

  • Kwon, Young-Il;Kang, Tae-Jin;Chung, Kwansoo;Youn, Jae Ryoun
    • Fibers and Polymers
    • /
    • 제2권4호
    • /
    • pp.203-211
    • /
    • 2001
  • Residual stresses were predicted by a flow analysis in the mold cavity and residual stress distribution in the injection molded product was measured. Flow field was analyzed by the hybrid FEM/FDM method, using the Hele Shaw approximation. The Modified Cross model was used to determine the dependence of the viscosity on the temperature and the shear rate. The specific volume of the polymer melt which varies with the pressure and temperature fields was calculated by the Tait\`s state equation. Flow analysis results such as pressure, temperature, and the location of the liquid-solid interface were used as the input of the stress analysis. In order to calculate more accurate gap-wise temperature field, a coordinate transformation technique was used. The residual stress distribution in the gap-wise temperature field, a coordinate transformation technique was used. The residual stress distribution in the gap-wise direction was predicted in two cases, the free quenching, under the assumption that the shrinkage of the injection molded product occurs within the mold cavity and that the solid polymer is elastic. Effects of the initial flow rate, packing pressure, and mold temperature on the residual stress distribution was discussed. Experimental results were also obtained by the layer removal method for molded polypropylene.

  • PDF

하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과 (Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정 (Surface Temperature Measurements in Microscale with Temperature Sensitive Fluorescence)

  • 정운섭;김성욱;김호영;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1225-1230
    • /
    • 2004
  • The effects of substrate material on the local heating performance of microheaters are studied by both numerical analysis and experiment. Transient conduction analysis shows that the substrate material with low thermal conductivity is critical to the local heating and fast response. A measurement technique for surface temperature field in microscale is newly proposed, which uses temperature sensitive fluorescent dye coated on the surface. The measured surface temperature fields on microheater arrays fabricated on different substrates are presented.

  • PDF