• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.032 seconds

A Feasibility Study of a Field-specific Weather Service for Small-scale Farms in a Topographically Complex Watershed (지형이 복잡한 집수역의 소규모농장에 맞춘 기상서비스의 실현가능성)

  • Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.317-325
    • /
    • 2015
  • An adequate downscaling of synoptic forecasts is a prerequisite for improved agrometeorological service to rural areas in South Korea where complex terrains and small farms are common. In this study, geospatial schemes based on topoclimatology were used to scale down the Korea Meteorological Administration (KMA) temperature forecasts to the local scale (~30 m) across a rural catchment. Then, using these schemes, local temperatures were estimated at 14 validation sites at 0600 and 1500 LST in 2013/2014 and were compared with the observations. The estimation errors were substantially reduced for both 0600 and 1500 LST temperatures when compared against the uncorrected KMA products. The improvement was most notable at low lying locations for the 0600 temperature and at the locations on west- and south-facing slopes for the 1500 LST temperature. Using the downscaled real-time temperature data, a pilot service has started to provide the field-specific weather information tailored to meet the requirements of small-scale farms. For example, the service system makes a daily outlook on the phenology of crop species grown in a given field using the field-specific temperature data. When the temperature forecast is given for next morning, a frost risk index is calculated according to a known relationship of phenology and frost injury. If the calculated index is higher than a pre-defined threshold, a warning is issued and delivered to the grower's cellular phone with relevant countermeasures to help protect crops against frost damage.

Effect of Otitis Media and Cerumen Occlusion on Body Temperature Measured by Thermometers (중이염과 귀지가 고막 체온에 미치는 영향)

  • Jeong, Seong Nam;Kim, Eun Sung;You, Ju Hee;Cho, Hyung Min;Yoo, Eun Jung;Kim, Eun Young;Kim, Kyoung Sim;Kim, Yong Wook
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.114-121
    • /
    • 2010
  • Purpose : To examine the effect of unilateral otitis media and unilateral cerumen occlusion of the ear canal on thermometers. Methods : One hundred eighty six children with unilateral otitis media, fifty children with unilateral cerumen occlusion, and fifty children with neither otitis media nor cerumen were enrolled. Temperature was measured in both ear canals using thermometers. After 15 minutes, second temperature was measured again in both ears. Unilateral otitis media was graded by video otoscope for 7 grades. Differences in temperatures between affected ears and unaffected ears were analyzed. Results : No temperature difference between the normal and cerumen groups was observed. The mean temperature of the otitis media ear canal was $0.13{\pm}0.20^{\circ}C$ higher than that of the intact ear canal ($36.99{\pm}0.54^{\circ}C$ vs $36.86{\pm}0.52^{\circ}C$; P<0.001). There was no statistically significant temperature difference between grades. Conclusion : Unilateral otits media can affect estimation of body temperature measured by thermometers.

A Study on the Assembling Mechanism of the Hairtail, Trichiurus Lepturus, at the Fishing Grounds of the Cheju Strait (제주해협 갈치(Hairtail,Trichiurus lepturus) 자원의 어장형성기구에 관한 연구)

  • Kim, Sag-Hyun;Rho, Hong-Kil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.117-134
    • /
    • 1998
  • The study on the Assembling Mechanism of the Hairtail, Trichiurus lenpturus, at the Fishing Grounds of the Cheju Strait had been investigated by analyzing the relationship of the oceanographic conditions and the fishing ground of the Hairtail in the Cheju Strait. 1. The fishing grounds of the hairtail at the Cheju Strait are formed at the bottom of a high temperature of the tidal front at the coast. area of northern Cheju Island, the tip of the linguiform is high in salinity at the eastern and western entrances of Cheju Island, low salinity eddy on the surface and its surrounding front, various water masses in the Strait and coastal waters of the South Sea in Korea. 2. The fishing grounds of the Hairtail at the Cheju Strait begins with the sea surface temperature higher than $15^{\circ}C$ and the incoming of low salinity water now from the East China Sea. 3. Estimation of optimum temperature and salinity per season based upon analysis for relationship between temperature of water and salinity of the bottom layer and the catch is : 15.2~$16.4^{\circ}C$, 34.20~34.40${\textperthousand}$ in spring(June); 14.4~ $17.0^{\circ}C$, 33.70~34.30${\textperthousand}$ in summer(July~September); and 15.7~ $18.6^{\circ}C$, 33.70~34.50$\textperthousand$ in autumn(October~December). Hairtail are mostly caught at the Yellow Sea Warm Current and Tsushima Current with temperature over $14.5^{\circ}C$ and salinity over 33.70${\textperthousand}$ at the bottom layers of the Cheju Strait. 4. Considering the relationship between the amount of hairtail catch and the water temperature of bottom layer, when the bottom water being above $14.0^{\circ}C$ flowed into Cheju Strait through the western entrance of the strait in summer, the ca-h appears to have been abundant. In contrast, the catch has been poor when the temperature of such water was recorded to be below $13^{\circ}C$ Therefore, distribution patterns of water at the bottom layer can be used as a forecast index whether the catch of a certain year will be good or poor.

  • PDF

Dynamic Characteristics of Seohae Cable-stayed Bridge Based on Long-term Measurements (장기계측에 의한 서해대교 사장교의 동특성 평가)

  • Park, Jong-Chil;Park, Chan-Min;Kim, Byeong-Hwa;Lee, Il-Keun;Jo, Byung-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.115-123
    • /
    • 2006
  • This paper presents long-term dynamic characteristics of a cable-stayed bridge where installed SHM (Structural Health Monitoring) system. Modal parameters such as natural frequencies and mode shapes are identified by modal analysis using three dimensional finite element model. The developed baseline model has a good correlation with measured natural frequencies identified from field ambient vibrations. By statistical data processing between measured natural frequencies and temperatures, it is demonstrated that the natural frequency is in linearly inverse proportion to the temperature. The estimation of temperature effects against frequency variations is performed. Mode shapes are identified from the TDD (Time Domain Decomposition) technique for ambient vibration measurements. Finally, these results demonstrate that the TDD method can apply to identify modal parameters of a cable-stayed bridge.

Antioxidants Supplementation on Acid Base Balance during Heat Stress in Goats

  • Sivakumar, A.V.N.;Singh, G.;Varshney, V.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.11
    • /
    • pp.1462-1468
    • /
    • 2010
  • The effects of vitamin C and vitamin E with selenium on acid-base balance and some stress hormones were evaluated during heat stress in goats. Goats, 1.5 years of age, were divided into control, heat stress and antioxidant treatment groups 1, 2 and 3. Except for the control, all groups were exposed to a temperature of $40{\pm}2^{\circ}C$ with a relative humidity of 30% for 5 h/d for 21 days in a psychrometric chamber. Rectal temperature and respiratory rates were recorded daily post exposure. Blood samples were collected on every 3rd day for estimation of plasma vitamins C and E, total antioxidant activity and hormones, and separate blood samples were taken to estimate acid-base status. The rectal temperature and respiratory rates were increased (p<0.05) in the heat stress group only. Except for pH and $pO_2$, which were increased significantly (p<0.05) other parameters of acid-base balance such as $pCO_2$, $HCO_3^-$, $TCO_2$, BEb, BEcef, PCV and Hb were significantly decreased (p<0.05) in the heat stress group. An improvement in acid-base status was noted in the antioxidant supplemented groups. Prolactin and cortisol levels were significantly (p<0.05) higher and free T3 and T4 levels were significantly (p<0.05) lower in the heat stress group. Levels of prolactin and cortisol were decreased and free T3 and T4 were increased in antioxidant treatment groups. Different levels of antioxidant supplementation resulted in similar protection against heat stress.

Variation of Floating Potential in the Topside Ionosphere Observed by STSAT-1

  • Lee, Junhyun;Lee, Ensang;Lee, Jaejin;Kim, Khan-Hyuk;Seon, Jongho;Lee, Dong-Hun;Jin, Ho;Kim, Eung-Hyun;Jeon, Hyun-Jin;Lim, Seong-Bin;Kim, Taeyoun;Jang, Jaewoong;Jang, Kyung-Duk;Ryu, Kwangsun
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.311-315
    • /
    • 2014
  • In this study, we investigated the effect of space plasmas on the floating potential variation of a low-altitude, polar-orbiting satellite using the Langmuir Probe (LP) measurement onboard the STSAT-1 spacecraft. We focused on small potential drops, for which the estimation of plasma density and temperature from LP is available. The floating potential varied according to the variations of plasma density and temperature, similar to the previously reported observations. Most of the potential drops occurred around the nightside auroral region. However, unlike the previous studies where large potential drops were observed with the precipitation of auroral electrons, the potential drops occurred before or after the precipitation of auroral electrons. Statistical analysis shows that the potential drops have good correlation with the temperature increase of cold electrons, which suggests the small potential drops be mainly controlled by the cold ionospheric plasmas.

Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings (건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델)

  • Baek, Seung Hyo
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

A Pressurized Water Reactor Power Controller Using Model Predictive Control Optimized by a Genetic Algorithm (유전자 알고리즘에 의해 최적화된 모델예측제어를 이용한 PWR 출력제어기)

  • Na, Man-Gyun;Hwang, In-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.104-106
    • /
    • 2005
  • In this work, a PWR reactor core dynamics is identified online by a recursive least squares method. Based on this identified reactor model consisting of the control rod position and the core average coolant temperature, the future average coolant temperature is predicted. A model predictive control method is applied to design an automatic controller for thermal power control in PWRs. The basic concept of the model predictive control is to solve an optimization problem for a finite future at current time and to implement as the current control input only the first optimal control input among the solutions of the finite time steps. At the next time step, the procedure to solve the optimization problem is then repeated. The objectives of the proposed model predictive controller are to minimize both the difference between the predicted core coolant temperature and the desired one, and the variation of the control rod positions. Also, the objectives are subject to maximum and minimum control rod positions and maximum control rod speed. Therefore, the genetic algorithm that is appropriate to accomplish multiple objectives is used to optimize the model predictive controller. A 3-dimensional nuclear reactor analysis code, MASTER that was developed by Korea Atomic Energy Research Institute (KAERI), is used to verify the proposed controller for a nuclear reactor. From results of numerical simulation to check the performance of the proposed controller at the 5%/min ramp increase or decrease of a desired load and its 10% step increase or decrease which are design requirements, it was found that the nuclear power level controlled by the proposed controller could track the desired power level very well.

  • PDF

Estimation Method of Residual Performance for Hollow Slab at Elevated Temperature (고온에 노출된 중공슬래브의 잔존성능 추정방법)

  • Choi, Hyun-Ki;Chung, Joo-Hong;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.643-650
    • /
    • 2014
  • Generally, the reinforced concrete slab has great fire resistance performance because concrete has excellent thermal material properties under fire. But, in the case of hollow slab, it will be expected that hollow slabs have different temperature distribution and fire endurance performance compare to reinforced concrete slab. Because hollow slab has internal void space that occurs decreasing regenerative effect of concrete and formation of internal air layer. Evaluation method for fire resistance performance of hollow slabs was proposed using $wickstr{\ddot{o}}m^{\prime}s$ method. For the casual use of evaluation, simplified method was proposed which was limited to solid slab and donut type hollow slab which was developed by authors of this research paper. Also, verification on proposed method was performed by comparing results of fire experiment for hollow slab and evaluation results. Proposed method of the results of this study was possible to predict the residual strength and temperature distribution of slabs under fire.

Development of CFD Model for Estimation of Cooling Effect of Fog Cooling System in Greenhouse (온실 포그냉방시스템의 냉방효과 예측을 위한 CFD 모델의 개발)

  • 유인호;김문기;권혁진;김기성
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.93-100
    • /
    • 2002
  • This study was carried out not only to develop CFD model for numerically simulating fog cooling system but also to verify the validity of the developed model by data measured in fag cooling greenhouse. In addition the developed model was applied to investigate the effects of spraying water temperature, spraying water amount, spraying interval and evaporation percentage on the performance of the fog cooling system. According to the simulation results, the temperature differences between the measured and predicted temperatures at each measurement point were $0.1~1.4^{\circ}C$ in case of no shading and $0.2~2.3^{\circ}C$ in close of shading. The humidity differences were 0.3~6.0% and 0.7~10.6%, respectively in the cases of no shading and shading. Because the predicted data showed a good agreement with the measured ones, the developed model is supposed to be able to predict the cooling effect of the fog cooling system. The performance of fog cooling system was greatly influenced by spraying water amount, spraying interval and evaporation percentage, but it was not influenced by spraying water temperature.