• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.034 seconds

Measurement and Numerical Analysis far Temperature near the Lockup Clutch (록업 클러치 주변의 온도 측정 및 수치 해석)

  • 고권현;유홍선;조성욱;이규봉
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.129-135
    • /
    • 2002
  • The present article deals with the measurement and the numerical calculations far the temperature distribution near the facing of the lockup clutch. The rotating telemetry system is Introduced for the estimation inside high-speed torque converter For the numerical calculation, the effect of the convective heat transfer is considered as well as the conduction to the solid. The estimation shows that the oil temperature near facing rapidly rises as the lockup clutch is engaged. The numerical results shows good agreements with the experimental values for the maximum temperature near the facing of the lockup clutch.

Zricaloy-4 Oxidation Kinetics in High-Pressure High-Temperature Steam and Application to Accident Analysis (고압 고온 수증기에서 지르칼로이-4 산화반응 정량화 및 사고해석에의 응용)

  • 박광헌
    • Journal of Surface Science and Engineering
    • /
    • v.35 no.6
    • /
    • pp.363-370
    • /
    • 2002
  • Empirical equations for the oxide thickness and the weight gain of Zircaloy-4 cladding during the oxidation in high temperature, high pressure steam have been developed. Firstly, the empirical equations for oxide thickness in 1 atm steam in 700~100$0^{\circ}C$ were made, then, the enhancement factor for the steam pressure effects on Zircaloy-4 cladding oxidation in high temperature steam was added. Based on the analysis of the weight fraction of dissolved oxygen in metal layer, empirical equations for the weight gain of Zircaloy-4 in high pressure, high temperature steam were developed. We compare the developed empirical equations with the Baker-Just correlation. The Baker-Just correlation can give a non-conservative estimation of oxidation of Zircaloy-4, depending on the steam pressure. These developed empirical equations can be used for the correct estimation of oxidation of Zircaloy-4 during accident analysis.

A Study on Estimation of Cooling Load Using Forecasted Weather Data (기상 예보치를 이용한 냉방부하 예측 기법에 관한 연구)

  • Han, Kyu-Hyun;Yoo, Seong-Yeon;Lee, Je-Myo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.937-942
    • /
    • 2008
  • In this paper, new methodology is proposed to estimate the cooling load using design parameters of building and predicted weather data. Only two parameters such as maximum and minimum temperature are necessary to obtain hourly distribution of cooling load for the next day. The maximum and minimum temperature that are used for input parameters can be obtained from forecasted weather data. Benchmarking building(research building) is selected to validate the performance of the proposed method, and the estimated cooling loads in hourly bases are calculated and compared with the measured data for benchmarking building. The estimated results show fairly good agreement with the measured data for benchmarking building.

  • PDF

Suggestion and Evaluation of a Multi-Regression Linear Model for Creep Life Prediction of Alloy 617 (Alloy 617의 장시간 크리프 수명 예측을 위한 다중회귀 선형 모델의 제안 및 평가)

  • Yin, Song-Nan;Kim, Woo-Gon;Jung, Ik-Hee;Kim, Yong-Wan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.366-372
    • /
    • 2009
  • Creep life prediction has been commonly used by a time-temperature parameter (TTP) which is correlated to an applied stress and temperature, such as Larson-Miller (LM), Orr-Sherby-Dorn (OSD), Manson-Haferd (MH) and Manson-Succop (MS) parameters. A stress-temperature linear model (STLM) based on Arrhenius, Dorn and Monkman-Grant equations was newly proposed through a mathematical procedure. For this model, the logarithm time to rupture was linearly dependent on both an applied stress and temperature. The model parameters were properly determined by using a technique of maximum likelihood estimation of a statistical method, and this model was applied to the creep data of Alloy 617. From the results, it is found that the STLM results showed better agreement than the Eno’s model and the LM parameter ones. Especially, the STLM revealed a good estimation in predicting the long-term creep life of Alloy 617.

A Study on Frost Occurrence Estimation Model in Main Production Areas of Vegetables (채소 주산지에 대한 서리발생예측 연구)

  • Kim, Yongseok;Hur, Jina;Shim, Kyo-Moon;Kang, Kee-Kyung
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.606-612
    • /
    • 2019
  • In this study, to estimate the occurrence of frost that has a negative effect on th growth of crops, we constructed to the statistical model. We factored such various meteorological elements as the minimum temperature, temperature at 18:00, temperature at 21:00, temperature at 24:00, average wind speed, wind speed at 18:00, wind speed at 21:00, amount of cloud, amount of precipitation within 5 days, amount of precipitation within 3 days, relative humidity, dew point temperature, minimum grass temperature and ground temperature. Among the diverse variables, the several weather factors were selected for frost occurrence estimation model using statistical methods: T-test, Variable importance plot of Random Forest, Multicollinearity test, Akaike Informaiton Criteria, and Wilk's Lambda values. As a result, the selected meteorological factors were the amount of cloud, temperature at 24:00, dew point temperature, wind speed at 21:00. The accuracy of the frost occurrence estimation model using Random Forest was 70.6%. When it applied to the main production areas of vegetables, a estimation accuracy of the model was 65.2 and 78.6%.

The Development of Estimation Model for Iron Compound Originated from Anaerobic Microbial Corrosion (혐기성 미생물부식에 의해 생성되는 철화합물 추정식 개발)

  • Jeon, Seok-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.379-386
    • /
    • 2002
  • In this study, estimation model for iron compound originated from upflow, anaerobic fixed bed reactor, which treats sewage domestic wastewater, was developed. The estimation model was formulated by a mathematical expression which was based on the mass balance. Below the HRT of 60 minute, sulfide concentration combining with iron $FeS_2$ is the highest because the maximum sulfate consumption rate $V_{maxS}$ and half-saturation constant of sulfate $K_{mS}$ exert an important effect on the estimation model as temperature was increased. But increment of $FeS_2$ concentration is weakened above the HRT of 60 minutes and represent the lowest value at the HRT of 108 minutes. It implies that liquid phase distribution ratio of sulfide ${\alpha}r$ becomes lower as temperature was increased. While phosphorus concentration combining with iron $Fe_3(PO_4)_3$ is increased as HRT and temperature are increased, which is affected by phosphorus removal rate constant $k_p$. As the result of estimating the iron concentrations of corrosion by the model, the concentration of iron corrosion is higher than any other at the HRT of 108 minute and $20^{\circ}C$. The predicted values were compared with measured ones at different HRT(13.5, 27, 54, 108 min) and temperature(20, 25, $30^{\circ}C$). The experimental data could be fitted with the simulated curves. Therefore, the mathematical expression could be applicable to design full-scale wastewater treatment plants.

On-board Capacity Estimation of Lithium-ion Batteries Based on Charge Phase

  • Zhou, Yapeng;Huang, Miaohua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.733-741
    • /
    • 2018
  • Capacity estimation is indispensable to ensure the safety and reliability of lithium-ion batteries in electric vehicles (EVs). Therefore it's quite necessary to develop an effective on-board capacity estimation technique. Based on experiment, it's found constant current charge time (CCCT) and the capacity have a strong linear correlation when the capacity is more than 80% of its rated value, during which the battery is considered healthy. Thus this paper employs CCCT as the health indicator for on-board capacity estimation by means of relevance vector machine (RVM). As the ambient temperature (AT) dramatically influences the capacity fading, it is added to RVM input to improve the estimation accuracy. The estimations are compared with that via back-propagation neural network (BPNN). The experiments demonstrate that CCCT with AT is highly qualified for on-board capacity estimation of lithium-ion batteries via RVM as the results are more precise and reliable than that calculated by BPNN.

The Study for Estimation of the Surface Temperature Rise in Spur Gear Tooth (Spur Gear 치면의 표면상승온도 예측에 관한 연구)

  • 김희진;구영필;조용주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.331-337
    • /
    • 2001
  • A numerical simulation of the temperature rise for sliding surface in dry contact is based on Jaegers formula combined with a calculated heat input. A gear tooth temperature analysis was performed. The pressure distribution has the Hertzian pressure distribution on the heat source. The heat partition factor is calculated along ling of action. A Temperature distribution of tooth surface is calculated about before and after profile modification. A Temperature of addendum and deddendum in modified gear have reduced.

  • PDF

The estimation of thermal diffusivity using NPE method (비선형 매개변수 추정법을 이용한 열확산계수의 측정)

  • 임동주;배신철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1679-1688
    • /
    • 1990
  • The method of nonlinear parameter estimation(NPE), which is a statistical and an inverse method, is used to estimate the thermal diffusivity of the porous insulation material. In order to apply the NPE method for measuring the thermal diffusivity, and algorithm for programing suitable to IBM personal computer is established, and is studied the statistical treatment of experimental data and theory of estimation. The experimental data obtained by discrete measurement using a constant heat flux technique are used to find the boundary conditions, initial conditions, and the thermal diffusivity, and then the final values are compared with the values obtained by some different methods. The results are presented as follows:(1) NPE method is used to establish the estimation of the thermal diffusivity and compared results with experimental output shows, that this method can be applicable to define the thermal diffusivity without considering hear flux types. (2) Because of all of the temperatures obtained by the discrete measurement on each steps of time are used to estimate the thermal diffusivity. Although some error in the temperature measurements of temperature are included in estimating process, its influences on the final value are minimzed in NPE method. (3) NPE method can reduce the experimental time including the time of data collecting in a few minutes and can take smaller specimen compared with steady state method. If the tube-type furnace is used, also the adjusting time of surrounding temperature can be reduced.