• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.033 seconds

A study of Determination of Frost penetration Depth in incheon Area (인천지역의 동결깊이산정에 관한 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.5-6
    • /
    • 2015
  • Recently, freezing index of frost penetration depth estimation used in Korea is applied according to the standard, published by MOLIT in 2003. However, it is difficult to consider can not be determined to standard reflects weather conditions in accordance with the current climate warming or abnormally high temperature. Also the temperature should be considered local variables because heavy local gap. Therefore, this study is through the freezing index presented in MOLIT's code by calculating the frost penetration depth determining whether the adequacy and conducted a study to apply in the field. As a result, when the Elevation 100m to standard in Incheon frost penetration depth is found to be 50.8cm.

  • PDF

Characteristic Variation of 3-D Solenoid Embedded Inductors for Wireless Communication Systems

  • Shin, Dong-Wook;Oh, Chang-Hoon;Kim, Kil-Han;Yun, Il-Gu
    • ETRI Journal
    • /
    • v.28 no.3
    • /
    • pp.347-354
    • /
    • 2006
  • The characteristic variation of 3-dimensional (3-D) solenoid-type embedded inductors is investigated. Four different structures of a 3-D inductor are fabricated by using a low-temperature co-fired ceramic (LTCC) process, and their s-parameters are measured between 50 MHz and 5 GHz. The circuit model parameters of each building block are optimized and extracted using the partial element equivalent circuit method and an HSPICE circuit simulator. Based on the model parameters, the characteristics of the test structures such as self-resonant frequency, inductance, and quality (Q) factor are analyzed, and predictive modeling is applied to the structures composed of a combination of the modeled building blocks. In addition, characteristic variations of the 3-D inductors with different structures using extracted building blocks are also investigated. This approach can provide a characteristic estimation of 3-D solenoid embedded inductors for structural variations.

  • PDF

Fuzzy inference based cover thickness estimation of reinforced concrete structure quantitatively considering salty environment impact

  • Do, Jeong-Yun
    • Computers and Concrete
    • /
    • v.3 no.2_3
    • /
    • pp.145-161
    • /
    • 2006
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and watercement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

Estimation of Thermal Conductivity at Liquid and Vapor Interface by Molecular Dynamics Simulation (분자동역학을 이용한 액상과 기상계면에서의 열전도율 예측)

  • Koo, Jin-Oh;Choi, Young-Ki;Lee, Joon-Sik;Park, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1558-1563
    • /
    • 2004
  • This work applies the nonequilibrium molecular dynamics simulation method to study a Lennard-Jones liquid thin film suspended in the vapor and calculates the thermal conductivity by linear response function. As a preliminary test, the thermal conductivity of pure argon fluid are calculated by nonequilibrium molecular dynamics simulation. It is found that the thermal conductivity decrease with decreasing the density. When both argon liquid and vapor phase are present, the effects of the system temperature on the thermal conductivity are investigated. It can be seen that the thermal conductivity of liquid-vapor interface is constant with increasing the temperature

  • PDF

Analysis on Surface Temperature Control of an Insulated Vertical Wall Under Thermal Radiation Environment (단열재가 부착된 수직벽 표면의 온도제어 해석)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.323-329
    • /
    • 2012
  • In this study, a rational procedures for estimation of insulation thickness of a vertical wall for condensation control or personnel protection has been investigated. Design parameters are height of the wall, thermal conductivity, emissivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient.

Application Strategies of Photovoltaic Energy in Ulsan (울산지역의 태양광에너지의 활용방안)

  • Lee, Kwan-Ho;Sim, Kwang-Yeal
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.320-323
    • /
    • 2009
  • Weather data is an important variable for the estimation value of the program for evaluating energy performance. The difference in data value of major weather elements used in weather data (temperature, insolation amount) were compared and analyzed. It was found that temperature showed similar values but insolation amount took different values. Especially in Ulsan, since the Meteorological Association does not measure insolation amount. To optimize the incident solar radiation, the solar azimuth angles are needed for solar photovoltaic systems. Test results shows that the $60^{\circ}$installation angel higher efficient than the $30^{\circ}$ installation angel in winter.

  • PDF

Conceptual design of current lead for large scale high temperature superconducting rotating machine

  • Le, T.D.;Kim, J.H.;Park, S.I.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.54-58
    • /
    • 2014
  • High-temperature superconducting (HTS) rotating machines always require an electric current of from several hundreds to several thousand amperes to be led from outside into cold region of the field coil. Heat losses through the current leads then assume tremendous importance. Consequently, it is necessary to acquire optimal design for the leads which would achieve minimum heat loss during operation of machines for a given electrical current. In this paper, conduction cooled current lead type of 10 MW-Class HTS rotating machine will be chosen, a conceptual design will be discussed and performed relied on the least heat lost estimation between conventional metal lead and partially HTS lead. In addition, steady-state thermal characteristic of each one also is considered and illustrated.

Estimation of fire-temperature through instrumental analysis of Fire- Damaged Concrete (화재 입은 콘크리트의 기기분석을 통한 화재온도 추정)

  • Kim, Seong-Su;Park, Kwang-Pil;Nam, Ba-Reum;Yoo, Ju-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.913-916
    • /
    • 2006
  • In this study, we conducted machinery analysis, such as differential thermal analysis, X-ray diffraction analysis and scanning electron microscope analysis, in order to predict fire temperature and to analyze fire damage in the case of fire on concrete structure. according to the machinery analysis and differential thermal analysis, concrete bought big creak over $300^{\circ}C$. these result can be utilized as good data in design for repair and reinforcement through rationally evaluating fire damage on concrete structure exposed to high heat or fire in the future.

  • PDF

Effects of Noble Gas on the Sonolytic Decomposition (초음파분해반응에 있어서 희가스의 영향)

  • 임봉빈;김선태
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.749-755
    • /
    • 2002
  • The effects of noble gas (such as helium, neon, argon, krypton, and xenon) on the sonolytic decomposition of water and 2-methyl-2-propanol(t-butanol) with 200 KHz high power ultrasound were investigated. The physical properties of the noble gas have an effect on the formation rate of products $(H_2O_2,\;H_2,\;O_2)$ and the decomposition rate on the sonolytic decomposition of water. The pyrolysis products, such as methane, ethane, ethylene, and acetylene are formed during the sonolytic decomposition of t-butanol. From the estimation of the ratio $[C_2H_4+C_2H_2] / [C_2H_6]$, the cavitation temperature would be varied by the used noble gas. In all cases for the sonolytic decomposition of water, t-butanol, and diethyl phthalate, the decomposition rates were xenon > krypton > argon > neon > helium with a significant difference and were closely correlated with the formation rate of OH radical and high temperature inside the cavitation bubble under each noble gas.

Estimation of Exhaust Gas Recirculation using In-Cylinder Residual Gas Fraction in an SI Engine (잔류가스 추정 기법을 이용한 EGR율의 예측)

  • 김득상;김성철;황승환;조용석;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.55-60
    • /
    • 2004
  • Residual gas acts as a diluent which results in reducing the in-cylinder temperature as well as the flame speed, significantly affecting fuel economy, NOx emissions and combustion stability. Therefore it is important to determine the residual gas fraction as a function of the engine operating parameters accurately. However, the determination of the residual gas fraction is very sophisticated due to the unsteady state of induction and exhaust process. There has been little work toward the development of a generally applicable model for quantitative predictions of residual gas fraction. In this paper, a simple model for calculating the residual gas fraction in SI engines was suggested. The amount of fresh air was evaluated through AFR and fuel consumption. After this, from the intake temperature and pressure, the amount of total cylinder-charging gas was estimated. The residual gas fraction was derived by comparing the total charging and fresh air. This results coincide with measured EGR value very well.