• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.041 seconds

Life Estimation of DC Link Electroytic Capacitors (직류 링크 전해 커패시터의 수명 추정)

  • 이동춘
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.57-60
    • /
    • 2000
  • An aluminum electrolytic capacitor is used in DC Link of ac motor drive system. In this case it usually has the shortest lifetime in the system and then determines the system lifetime. Therefore life estimation of the electrolytic capacitor is needed for maintenance of th circuit. In this paper a method for life estimation is presented with a ESR(equivalent series resistance) model and a heat transfer model of capacitor that can be used to estimate operating temperature it is investigated through a simple example using ESR and heat transfer.

  • PDF

An Experimental Anlysis in Non-Circular Tube Extrusion Using the Effective Extrusion Ratio (비원형 중공 압출의 유효 압출비를 이용한 실험적 해석)

  • 한철호;김상화
    • Transactions of Materials Processing
    • /
    • v.8 no.5
    • /
    • pp.520-526
    • /
    • 1999
  • In this study a practical formula based on the experime수 랙 the estimation of load in the non-circular tube extrusion with the mandrel is proposed by using the effective extrusion ratio. Through some experiments for the several shaped sections, the coefficients of the empirical equation are determined by ticine as a model material at room temperature. The proposed empirical formula for the estimation of extrusion load will be applicable to the non-steady state as well as steady state for the extrusion of various shaped tubes from hollow billets.

  • PDF

The Estimation of Surface Temperature of Concrete Frame Caused by Fire (구체콘크리트면에 받는 열온도의 시뮬레이션 실험)

  • Nakagawa. Muneo;Kei. Yanagi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.272-277
    • /
    • 1997
  • The object of this paper is to analyze the surface temperature of RC structures caused by fire. The experimental analysis is undertaken by using following two methods. 1) Simulation to analyze the relationship between the temperature and the condition change for glass wool caused by fire. 2) Temperature-analysis (TG/DTA tests) of RC structures. From the results of the two experimental analysis, it was possible to estimate the temperature of RC concrete structures caused by fire.

  • PDF

Estimation of Temperature Distribution on Wafer Surface in Rapid Thermal Processing Systems (고속 열처리공정 시스템에서의 웨이퍼 상의 온도분포 추정)

  • Yi, Seok-Joo;Sim, Young-Tae;Koh, Taek-Beom;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.4
    • /
    • pp.481-488
    • /
    • 1999
  • A thermal model based on the chamber geometry of the industry-standard AST SHS200MA rapid thermal processing system has been developed for the study of thermal uniformity and process repeatability thermal model combines radiation energy transfer directly from the tungsten-halogen lamps and the steady-state thermal conducting equations. Because of the difficulties of solving partial differential equation, calculation of wafer temperature was performed by using finite-difference approximation. The proposed thermal model was verified via titanium silicidation experiments. As a result, we can conclude that the thermal model show good estimation of wafer surface temperature distribution.

  • PDF

Accelerated Insulation Life Estimation for PAI/Nano Silica Enamelled Wire under Inverter Surge and Temperature Stress (인버터 서지와 온도스트레스 하에서 PAI/Nano Silica 에나멜와이어의 가속절연수명 평가)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1712-1720
    • /
    • 2016
  • AC and DC insulation breakdown voltage was studied for magnet wire coated with double layers of high flexural PAI layer and high anti-corona PAI/nanosilica (15 wt%) layer. The specimens were prepared at various drying temperatures (T/D): $22^{\circ}C$, $240^{\circ}C$, and $260^{\circ}C$, respectively. The increase effects of nanosilica on AC and DC insulation breakdown voltage were not so significant compared to that of magnet wire coil coated with original PAI. And the AC and DC insulation breakdown voltage was improved by decreasing diameter of winding coil. As T/D temperature increased, AC and DC insulation breakdown voltage decreased.

Thermal Lifetime Estimation of Coil Used for Dry-type Transformer (건식변압기 코일의 열적 수명평가)

  • Kim, M.K.;Huh, D.H.;Kim, I.S.;Jang, J.Y.;Moon, B.C.;Go, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.131-132
    • /
    • 2008
  • This paper describes a method to estimate the thermal lifetime of coil used in the dry-type molded transformer which is widely used in the domestic distribution system. In order to reduce the testing time, temperature accelerated aging test is planned. Finally, the thermal lifetime estimation method is composed of a temperature aging test and a cyclic test of temperature, humidly and lightning impulse voltage withstand test.

  • PDF

Reaction heat estimation of industrial batch reactors (산업용 회분식 반응기에서의 반응열 추정)

  • 방성호;이대욱;이광순;이석호;손종상;윤상철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.595-600
    • /
    • 1993
  • The heat of reaction has been estimated from heat balance relationships around the reactor. The heat balance equations were formulated with the assumptions that the reactor temperature is uniformly distributed and the jacket temperatures are axially distributed. We have obtained the temperature distribution of jacket contents by FDM. And then, we have rearranged the heat balance equations so that the heat of reaction can be estimated from the finite number of temperature measurements, i.e., temperatures of the reactor contents, at the jacket inlet and outlet, respectively. The proposed method for reaction heat estimation on were applied to industrial batch reactors ; one is ABS polymerization reactor and the other is SAN polymerization reactor. We have also examined the variation of overall heat transfer coefficients for the reactors during reaction.

  • PDF

Calculation of the Convective Mixed Layer by Estimation of Sensible Heat Flux (현열 플럭스 추정에 의한 대류 혼합층 고도의 산출)

  • 김용국
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.639-645
    • /
    • 1998
  • A Jump model was evaluated for the calculation of hourly mixing height and mean potential temperature within the height. The Sump model was modified for estimation of downward heat fluxes by mechanical convections and surface heat fluxes. The surface heat fluxes were estimated from routine weather data such as solar radiation and air temperature. Total of 8 upper-air data observed at 0000UTC and 0600UTC in Osan station during April 23 to 26, 1996 were analyzed, and compared to the model results in detail. The calculated mixing heights and potential temperatures within the height were comparable to the observations, but some differences were showed. The calculated mixing heights were generally higher than observations. And, when variations of wind directions were large, the large difference of potential temperature was occurred. From the results, it was important to note that vortical motions and advections of air masses would affect to the growth of the mixing height.

  • PDF

Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator (제상 히터와 냉장고 플라스틱 내벽 사이의 안전거리에 대한 모델링)

  • Jung, Young;Shin, Jong-Min;Tikhonov, Alexei V.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80'C , which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 6$0^{\circ}C$ during defrosting process.

A Study on The Conductor Temperature Estimation of Underground Power Cables Considering the Load Current Change (부하전류를 고려한 지중 전력케이블의 도체온도 추정에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Nam, K.Y.;Ryoo, H.S.;Kang, J.W.;Jang, T.I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.247-249
    • /
    • 2003
  • This paper presents the analysis of the transient temperature rise at the surface of underground power cables and an estimation of conductor temperature considering the power load change of underground power cables.

  • PDF